Search results for "Bone"
showing 10 items of 2629 documents
Early bone healing around implant surfaces treated with variations in the resorbable blasting media method. A study in rabbits.
2010
Objective: this study aimed to histomorphologically and histomorphometrically evaluate the in vivo response to three variations in the resorbable blasting media (RBM) surface processing in a rabbit femur model. Study Design: screw root form implants with 3.75 mm in diameter by 8 mm in length presenting four surfaces (n=8 each): alumina-blasted/acid-etched (AB/AE), bioresorbable ceramic blasted (TCP), TCP + acid etching, and AB/AE + TCP were characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The implants were placed at the distal femur of 8 New Zeland rabbits, remaining for 2 weeks in vivo. After sacrifice, the implants were nondecalcified processed to 30 …
Oral rehabilitation with tilted dental implants: A metaanalysis
2012
Objective: To compare the course of patients treated with tilted implants versus those treated conventionally with axial implants, analyzing the success rate and marginal bone loss. Material and M ethods: A PubMed search was made using the key words ?tilted implants?, ?angled implants?, ?angulated implants?, ?inclined implants? and ?maxillary atrophy.? A review was made of the articles published between 1999-2010. The inclusion criteria were the use of tilted implants, clinical series involving at least 10 patients, and a minimum follow-up of 12 months after prosthetic loading. The exclusion criteria were isolated clinical cases, studies with missing data, and publications in languages othe…
Marginal bone loss in relation to the implant neck surface: An update
2010
A review is made of the publications on the marginal bone loss of implants with a polished neck, rough neck with microthreading, and rough neck without microthreading. A PubMed search was carried out with the following key words: machined neck implant, polished neck implant, marginal bone loss, covering the period between January 1998 and March 2009. Inclusion was limited to those human clinical studies involving a minimum follow-up of 12 months, and registering the level of bone loss from the time of placement of the implant or prosthetic restoration to the end of follow-up. For most of the authors there were no significant differences in marginal bone loss between polished neck and rough …
Effects of a local single dose administration of growth hormone on the osseointegration of titanium implants.
2021
The aim of the present study was to evaluate the effect of different concentrations of growth hormone (GH) on endosteal implant?s surface at the early stages of osseointegration. Sixty tapered acid-etched titanium implants were divided into four groups: i) Collagen, used as a control group; and three experimental groups, where after collagen coating, GH was administered directly to the surface in varying concentrations: ii) 0.265 mg, iii) 0.53 mg, and iv) 1 mg. Implants were placed in an interpolated fashion in the anterior flange of C3, C4 or C5 of 15 sheep with minimum distance of 6 mm between implants. After 3-, 6- and 12-weeks of healing samples were harvested, histologically processed,…
Impact of abutment geometry on early implant marginal bone loss. A double‐blind, randomized, 6‐month clinical trial
2022
Objectives The objective of this study was to analyze the impact of the abutment width on early marginal bone loss (MBL). Material and Methods A balanced, randomized, double-blind clinical trial with two parallel experimental arms was conducted without a control group. The arms were “cylindrical” abutment and “concave” abutment. Eighty hexagonal internal connection implants, each with a diameter of 4 × 10 mm, were placed in healed mature bone. The main variable was the peri-implant tissue stability, which was measured as MBL at 8 weeks and 6 months. Results The final sample consisted of 77 implants that were placed in 25 patients. 38 (49.4%) were placed using the cylindrical abutment, and t…
Bone regeneration using particulate grafts : an update
2010
Objective: A review is made of the publications on bone regeneration using particulate grafts, with an evaluation of the success of implants placed in such regenerated areas. Material and Method: A Medline search using different key words was made of the articles published between 1999-2009 involving at least two patients subjected to grafting with autologous, homologous or xenogenic bone, non-bony substitutes, or a combination of these grafts for the placement of dental implants. Studies involving block grafting were excluded. A total of 11 studies were evaluated. Results: These grafts are indicated in cases of small or peri-implant bone defects such as dehiscences and fenestrations, with …
Meta-analysis on the survival of short implants
2010
Objective: To evaluate the success and failure rates of short implants (10 mm or less) for oral rehabilitations in cases of limited bone height. Study Design: Review of the articles published on the topic between the years 2000 and 2010, and development of a descriptive meta-analysis of the results. Results: The majority of the studies obtain a cumulative success rate (CSR) similar to that of longer implants (92.5% - 98.42% for machined and rough-surface implants, respectively). The studies that record lower cumulative success rates (CSR) are later studies that analyze implants with a machined surface. Almost none of the studi-es compared the success/failure rates with the bone quality or l…
Comparison of conventional twist drill protocol and piezosurgery for implant insertion: an ex vivo study on different bone types.
2015
Objective The aim of this ex vivo study was to compare implant insertion procedures using piezosurgery and conventional drilling in different qualities of bone. Implant bed preparation time, generated heat, and primary implant stability were analyzed. Material and methods Fresh ex vivo porcine bone block samples (cancellous, mixed, and cortical bone) were obtained. The bone quality was quantified by ultrasound transmission velocity (UTV). Each bone sample received three implants of the same diameter using each of the techniques of piezosurgery and conventional twist drills. Time for preparation was taken and the temperature while performing the osteotomy was measured using infrared spectros…
Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series
2016
Background: The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. Material and Methods: A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and…
Medication-related osteonecrosis of the jaw associated with implant and regenerative treatments : systematic review
2019
Background The aim of this study was to determine if the treatment with bisphosphonates other anti-resorptive and antiangiogenic agents influences the success of regenerative and / or implant treatments. Material and Methods We reviewed the literature from the last 5 years in the PubMed database, using the following words: “Sinus Floor Augmentation”[Mesh] OR “Dental Implants”[Mesh]) OR “Guided Tissue Regeneration”[Mesh]) AND “Osteonecrosis”[Mesh]. The articles were selected following the inclusion and exclusion criteria and were evaluated using the 22 items of the STROBE declaration. The following PICO clinical question was applied: Does the treatment with agents associated with drug osteon…