Search results for "Brachytherapy"
showing 10 items of 168 documents
Intramural neovascularization and haemorrhages are major long‐term effects of intravascularγ‐radiation after stenting
2003
Structural changes that might influence the structural integrity of the vessel in response to intravascular brachytherapy (IVB) and stenting were examined, focus being on the importance of neovascularization in rabbit stented arteries. Stents were implanted in the infrarenal aortas of rabbits, immediately followed by gamma IVB or a sham radiation procedure, and the arteries harvested at 6 months. Labelling for von Willebrand factor showed an increase in adventitial and medial neovascularization in irradiated versus control arteries group (5.04+/-0.89 versus 1.51+/-0.23 mm(-2), respectively; p=0.004). Moreover, intramedial haemorrhages (free hemosiderin deposition) and inflammation (macropha…
Salvage reirradiation for locoregional failure after radiation therapy for prostate cancer: Who, when, where and how?
2014
Even in the current era of dose-escalated radiotherapy for prostate cancer, biochemical recurrence is not uncommon. Furthermore, biochemical failure is not specific to the site of recurrence. One of the major challenges in the management of prostate cancer patients with biochemical failure after radiotherapy is the early discrimination between those with locoregional recurrence only and those with metastatic disease. While the latter are generally considered incurable, patients with locoregional disease may benefit from emerging treatment options. Ultimately, the objective of salvage therapy is to control disease while ensuring minimal collateral damage, thereby optimizing both cancer and t…
DEXAMETHASONE INTRAVITREAL IMPLANT VS RANIBIZUMAB IN THE TREATMENT OF MACULAR EDEMA SECONDARY TO BRACHYTHERAPY FOR CHOROIDAL MELANOMA
2017
PURPOSE To evaluate the efficacy of an intravitreal dexamethasone (Dex) implant 0.7 mg compared with intravitreal ranibizumab (Ra) for the treatment of radiation maculopathy with macular edema secondary to plaque brachytherapy in choroidal melanoma. METHODS Eight patients were treated with intravitreal Ra, and eight patients received the Dex intravitreal implant. Visual acuity and foveal thickness were evaluated using spectral domain optical coherence tomography. RESULTS The mean calculated irradiation to the fovea and mean times from brachytherapy to maculopathy development did not differ significantly between groups. In the Ra group, a mean 7.8 ± 3.9 injections were given and the mean fol…
Brachytherapy organ dose estimation using Monte Carlo simulations of realistic patient models
2018
Radiation Therapy Planning Systems (RTPS) currently used in hospitals contain algorithms based on deterministic simplifications that do not properly consider electrons lateral transport in the areas where there are changes of density, and as a result, erroneous dose predictions could be produced. According to this, the present work proposes the use of Monte Carlo method in brachytherapy planning systems, which could affect positively on the radiotherapy treatment planning, since it provides results that are more accurate and takes into account the in homogeneities density variations. This paper presents a Monte Carlo (MC) simulation of a brachytherapy prostate treatment with I-125 seeds, us…
Primary Radical Prostatectomy or Ablative Radiotherapy as Protective Factors for Patients With mCRPC Treated With Radium-223 Dichloride: An Italian M…
2020
Abstract Background We investigated, in a real-life setting, the prognostic relevance of previous primary treatment (radical prostatectomy [RP] or external beam radiotherapy [EBRT]) on overall survival for patients with metastatic castration-resistant prostate cancer (mCRPC) treated with radium-223 (223Ra). Materials and Methods In the present multicenter retrospective study, we enrolled 275 consecutive patients. The demographic and clinical data and mCRPC characteristics were recorded and evaluated at baseline and at the end of treatment or progression. 223Ra was administered according to the current label authorization until disease progression or unacceptable toxicity. We divided the who…
Is high dose rate brachytherapy reliable and effective treatment for prostate cancer patients? A review of the literature.
2014
The intrinsic physical and radiobiological characteristics of High Dose Rate Brachytherapy (HDR-BT) are well suited to the treatment of prostate cancer. HDR-BT was initially used as a boost to external beam brachytherapy, but has subsequently been employed as the sole treatment, which is termed HDR monotherapy. This review summarizes the clinical outcomes and toxicity results of the principal studies and discusses the radiobiological basis supporting its use.
Multiparametric MRI and post implant CT-based dosimetry after prostate brachytherapy with iodine seeds: The higher the dose to the dominant index les…
2015
Abstract Purpose To determine whether post-implant MRI-based dosimetry of the Dominant Intra-prostatic Lesion (DIL) could best predict the occurrence of PSA bounce after prostate brachytherapy. Methods and materials We selected 66 patients with a low risk prostate cancer treated with 125 I prostate brachytherapy as monotherapy. Post-implant dosimetry based on day 30 CT-scan and multiparametric MRI co-registration was generated: planned D 90, D 95, V 100, V 150 values were calculated for each DIL. Bounce was defined as a PSA elevation ⩾0.2ng/mL from the previous baseline value followed by a decrease to or below the prior nadir with no additional treatment. Results After a median follow-up of…
Interactive multiobjective optimization for anatomy-based three-dimensional HDR brachytherapy.
2010
In this paper, we present an anatomy-based three-dimensional dose optimization approach for HDR brachytherapy using interactive multiobjective optimization (IMOO). In brachytherapy, the goals are to irradiate a tumor without causing damage to healthy tissue. These goals are often conflicting, i.e. when one target is optimized the other will suffer, and the solution is a compromise between them. IMOO is capable of handling multiple and strongly conflicting objectives in a convenient way. With the IMOO approach, a treatment planner’s knowledge is used to direct the optimization process. Thus, the weaknesses of widely used optimization techniques (e.g. defining weights, computational burden an…
Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations
2014
Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a …
Fogging effect correction of Gafchromic HD-V2 film response for its use in high-dose radiotherapy
2020
GAFChromic® HD-V2 film is a reliable dose measurement device, thin, flexible, inexpensive, simple to use and easy to analyze. The response in terms of net absorbance with respect to absorbed dose was found to be linear in a large dose range, which supports the feasibility of using the film dosimeters in many applications, such as radiotherapy. For its use, a "fogging" effect must be take into account since film response changes with time. To determine a calibration curve valid for any time, fogging effect was investigated for more than 400 days. A correction procedure allows the use of HD-V2 film dosimeters in high-dose radiotheraphy, as brachytherapy, and quality assurance (QA) procedures.