Dosimetric characterization of Ir-192 LDR elongated sources
2008
Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources, (ii) the wire is modeled as a set of small straight segment wires, (iii) the values of the parameters and functions of the American Association of Physicists in Medicine (AAPM) Task Group 43 protocol are obtained for wire lengths between 3 and 7 cm assuming some simplifications. The dose rate distributions obtained using these methods for linear wires of different lengths and …
Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data
2014
Purpose: To provide a method for calculating the transmission of any broad photon beam with a known energy spectrum in the range of 20–1090 keV, through concrete and lead, based on the superposition of corresponding monoenergetic data obtained from Monte Carlo simulation. Methods: MCNP5 was used to calculate broad photon beam transmission data through varying thickness of lead and concrete, for monoenergetic point sources of energy in the range pertinent to brachytherapy (20–1090 keV, in 10 keV intervals). The three parameter empirical model introduced byArcher et al. [“Diagnostic x-ray shielding design based on an empirical model of photon attenuation,” Health Phys. 44, 507–517 (1983)] was…
Monte Carlo dosimetry of the Buchler high dose rate 192Ir source.
2001
In this study a complete set of dosimetric data is presented for the high dose rate (HDR) source from Amersham used in the Buchler remote afterloading HDR unit. These data have been calculated by means of the Monte Carlo simulation code GEANT taking into account the detailed geometry of the source. Absolute dose rate distributions in water were calculated around this source and are presented as conventional 2D Cartesian look-up tables. All dosimetric quantities recommended by the AAPM Task Group 43 report have been calculated. Quantities determined are: dose rate constant, radial dose function, anisotropy function, anisotropy factor and anisotropy constant. The dose rate distributions of th…
SU-FF-T-180: Dosimetric Characteristics of Tm-170 as a Radionuclide for Its Possible Use in Brachytherapy
2006
In clinical brachytherapy several types of photon sources are used, mainly Cs‐137, Ir‐192, I‐125, and Pd‐103. The Tm‐170 is a promising radionuclide for use in brachytherapy because of the low mean‐energy (46.75 keV or 66.39 keV if the lines below 10 keV are removed) and the possible high specific activity (2.21×1014 Bq/g for a half life of 128.6 days). Tm‐170 is produced in a nuclear reactor by neutron absorption of the natural Tm‐169 and decays mainly via β‐emission. The maximum energies of the β‐rays are 0.290 and 0.323 MeV. These β particles are thus absorbed in the source core and in the encapsulation cover producing bremsstrahlung that contributes significantly to the dose. These fact…
TH-C-AUD A-08: Evaluation of Electronic Equilibrium Conditions Near Brachytherapy Sources
2008
Purpose: For high‐energy photon‐emitting brachytherapysources such as 60 Co , 137 Cs , 192 Ir , and 169 Yb , the main contribution of the systematic uncertainty in the dose distributions near the sources is understanding of electronic equilibrium and the contribution of β‐rays due to radioactive disintegration. Thus, it is important to study these effects in detail to accurately depict dose distributions near these brachytherapysources. This work studies the relative importance of β‐ray contributions to total dose (β + γ + x‐ray), and feasibility of using the approximation “collision kerma equals dose in electronic equilibrium conditions.” Method and Materials:Characteristics of kerma and d…
Influence of photon energy spectra from brachytherapy sources on Monte Carlo simulations of kerma and dose rates in water and air
2010
Purpose: For a given radionuclide, there are several photonspectrum choices available to dosimetry investigators for simulating the radiation emissions from brachytherapy sources. This study examines the dosimetric influence of selecting the spectra for I 192 r , I 125 , and P 103 d on the final estimations of kerma and dose. Methods: For I 192 r , I 125 , and P 103 d , the authors considered from two to five published spectra. Spherical sources approximating common brachytherapy sources were assessed. Kerma and dose results from GEANT4, MCNP5, and PENELOPE-2008 were compared for water and air. The dosimetric influence of I 192 r , I 125 , and P 103 d spectral choice was determined. Results…
Dosimetry characteristics of the Plus and 12i Gammamed PDR 192Ir sources.
2001
In this study a complete set of dosimetric data for the Plus and 12i Gammamed PDR (pulsed dose rate) 192 Ir sources is presented. These data have been calculated using the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water around these sources were calculated and are presented in form of conventional two dimensional (2D) Cartesian look-up tables. All dosimetric quantities recommended by the AAPM Task Group 43 report have been also calculated. These quantities are dose rate constant, radial dose function, anisotropy function and anisotropy factor. The dose rate distribution of the 12i source was compared with the corresponding data for the microselectron PDR source…
A generic high-dose rate192Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism
2015
Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-b ...
SU-F-T-13: Transit Dose Comparisons for Co-60 and Ir-192 HDR Sources
2016
Purpose: The purpose of this study is to compare the transit dose due to the movement of high dose rate (HDR) Ir-192 and Co-60 sources along the transfer tube. This is performed by evaluating air-kerma differences in the vicinity of the transfer tube when both sources are moved with the same velocity from a HDR brachytherapy afterloader into a patient. Methods: Monte Carlo simulations have been performed using PENELOPE2014. mHDR-v2 and Flexisource sources have been considered. Collisional kerma has been scored. The sources were simulated within a plastic catheter located in an infinite air phantom. The movement of the seed was included by displacing their positions along the connecting cath…
A Monte Carlo investigation of the dosimetric characteristics of the CSM11 137Cs source from CIS
2000
The purpose of this study is to calculate basic dosimetry data for a CSM11 low dose rate 137Cs source in water. This source is widely used in afterloadable dome cylinders designed to homogeneously irradiate the vaginal cuff alone or additional areas of the vagina in hysterectomized patients. In this study, the Monte Carlo simulation code GEANT, incorporating in detail source geometry, is used to investigate the dosimetric characteristics of the source. The calculated data were analyzed using a fitting procedure that is described in detail. Absolute dose rate distributions in water were calculated around this source and are presented as conventional 2D Cartesian lookup tables (classically al…