Search results for "Brea"
showing 10 items of 4298 documents
Exercise intolerance at high altitude (5050 m): critical power and W'.
2011
Abstract The relationship between work rate (WR) and its tolerable duration (tLIM) has not been investigated at high altitude (HA). At HA (5050 m) and at sea level (SL), six subjects therefore performed symptom-limited cycle-ergometry: an incremental test (IET) and three constant-WR tests (% of IET WRmax, HA and SL respectively: WR1 70 ± 8%, 74 ± 7%; WR2 86 ± 14%, 88 ± 10%; WR3 105 ± 13%, 104 ± 9%). The power asymptote (CP) and curvature constant (W′) of the hyperbolic WR–tLIM relationship were reduced at HA compared to SL (CP: 81 ± 21 vs. 123 ± 38 W; W′: 7.2 ± 2.9 vs. 13.1 ± 4.3 kJ). HA breathing reserve (estimated maximum voluntary ventilation minus end-exercise ventilation) was also comp…
Cardiac surgery outcomes in patients with coronavirus disease 2019 (COVID-19): A case-series report
2020
Abstract Objective The impact of coronavirus disease 2019 (COVID-19) on the postoperative course of patients after cardiac surgery is unknown. We experienced a major severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) outbreak in our cardiac surgery unit, with several patients who tested positive early after surgery. Here we describe the characteristics, postoperative course, and laboratory findings of these patients, along with the fate of the health care workers. We also discuss how we reorganize and reallocate hospital resources to resume the surgical activity without further positive patients. Methods After diagnosis of the first symptomatic patient, surgery was suspended. Naso…
Non-contact breath sampling for sensor-based breath analysis
2019
Breath analysis holds great promise for real-time and non-invasive medical diagnosis. Thus, there is a considerable need for simple-in-use and portable analyzers for rapid detection of breath indicators for different diseases in their early stages. Sensor technology meets all of these demands. However, miniaturized breath analyzers require adequate breath sampling methods. In this context, we propose non-contact sampling; namely the collection of breath samples by exhalation from a distance into a miniaturized collector without bringing the mouth into direct contact with the analyzing device. To evaluate this approach different breathing maneuvers have been tested in a real-time regime on a…
Effect of Salmeterol on Seasonal Changes in Airway Responsiveness and Exhaled Nitric Oxide in Pollen-Sensitive Asthmatic Subjects
2002
Objective Using a model of natural allergen exposure, we examined the effect of regular treatment with salmeterol on allergen-induced changes in airway responsiveness and exhaled nitric oxide (ENO). Design Double-blind, randomized, parallel-group study. Setting Specialist allergy unit in a university hospital. Patients Asthmatic patients sensitized to pollen allergens were randomly allocated to monotherapy with salmeterol (n = 14) or placebo (n = 13). Interventions Salmeterol, 25 μg, and placebo inhalers, two puffs bid, for 6 weeks. Measurements Spirometry, the level of a provocative concentration of a substance (methacholine) causing a 20% fall in FEV 1 (PC 20 ), the PC 20 level for adenos…
Detection of lung cancer in exhaled breath with an electronic nose using support vector machine analysis
2017
Lung cancer is one of the most common malignancies and has a low 5-year survival rate. There are no cheap, simple and widely available screening methods for the early diagnostics of lung cancer. The aim of this study was to determine whether analysis of exhaled breath with an artificial olfactory sensor using support vector analysis can differentiate patients with lung cancer from healthy individuals and patients with other lung diseases, regardless of the stage of lung cancer and the most common comorbidities. Patients with histologically or cytologically verified lung cancer, healthy volunteers and patients with other lung diseases (e.g. chronic obstructive pulmonary disease (COPD), asthm…
Measurement of Fractional Exhaled Nitric Oxide: Comparison of Three Different Analysers
2019
<b><i>Background:</i></b> Fractional exhaled nitric oxide (FeNO) is a surrogate marker for airway inflammation, supporting the diagnostic pathway and treatment decisions for asthma patients. <b><i>Objectives:</i></b> Aim of this study was to compare the new analyser Vivatmo pro (Bosch, BV) with NIOX VERO (Circassia, CN) and CLD (Ecomedics, EC). <b><i>Methods:</i></b> In 100 asthmatics (median 53 years [range 20–87], 62% female, 86% on inhaled corticosteroids [mean 1,300 μg beclomethasone dipropionate or equivalent], 35% treated with biologics) 2 FeNO measurements per device were performed. Additionally, the success rate…
Is Health-Related Quality of Life Associated with Upper and Lower Airway Inflammation in Asthmatics?
2013
Background.Allergic diseases impair health-related quality of life (HR-QoL). However, the relationship between airway inflammation and HR-QoL in patients with asthma and rhinitis has not been fully investigated. We explored whether the inflammation of upper and lower airways is associated with HR-QoL.Methods.Twenty-two mild allergic asthmatics with concomitant rhinitis (10 males, 38 ± 17 years) were recruited. The Rhinasthma was used to identify HR-QoL, and the Asthma Control Test (ACT) was used to assess asthma control. Subjects underwent lung function and exhaled nitric oxide (eNO) test, collection of exhaled breath condensate (EBC), and nasal wash.Results.The Rhinasthma Global Summary sc…
Performance of EasyBreath Decathlon Snorkeling mask for delivering continuous positive airway pressure
2021
AbstractDuring the COVID-19 pandemic, the need for noninvasive respiratory support devices has dramatically increased, sometimes exceeding hospital capacity. The full-face Decathlon snorkeling mask, EasyBreath (EB mask), has been adapted to deliver continuous positive airway pressure (CPAP) as an emergency respiratory interface. We aimed to assess the performance of this modified EB mask and to test its use during different gas mixture supplies. CPAP set at 5, 10, and 15 cmH2O was delivered to 10 healthy volunteers with a high-flow system generator set at 40, 80, and 120 L min−1 and with a turbine-driven ventilator during both spontaneous and loaded (resistor) breathing. Inspiratory CO2 par…
Physiological responses and parasympathetic reactivation in rescue interventions: The effect of the breathing apparatus.
2018
This study aimed to assess the effect of wearing a breathing apparatus during a simulated rescue intervention on psychophysiological responses and parasympathetic reactivation of firefighters. Thirty-four firefighters participated in this study which consisted of four experimental sessions conducted randomly: a maximal fitness test and three rescue interventions performed (a) with personal protective clothing (PPC); (b) with PPC and the full self-contained breathing apparatus (SCBA), including cylinder, full-face piece, and breathing regulator; and (c) with PPC and only the cylinder of the self-contained breathing apparatus (SCBAc). Physiological (heart rate [HR], breathing frequency [BF]) …
Reanimation of the Paralyzed Human Larynx With an Implantable Electrical Stimulation Device
2003
Objectives/Hypothesis Electrical stimulation of the posterior cricoarytenoid muscle, when paced with inspiration, offers a physiological approach to restore ventilation in bilateral laryngeal paralysis without any of the disadvantages associated with conventional treatment. Study Design A prospective study of six patients. Methods The patients were successfully implanted with an Itrel II stimulator (Medtronic, Inc). In postoperative sessions, stimulated vocal fold abduction, patient ventilation, and voice were assessed and compared with preoperative values. Results The optimum stimulus paradigm was a 1- to 2-second train of 1-millisecond pulses delivered at a frequency of 30 to 40 Hz and am…