Search results for "Breath tests"
showing 10 items of 68 documents
Quantitative evaluation of ethane and n-pentane as indicators of lipid peroxidation in vivo.
1983
The use of exhalation of ethane and n-pentane in experimental animals as parameters of lipid peroxidation led to an examination of pharmacokinetics of both compounds in rats. When rats were exposed, in a closed desiccator jar chamber, to a wide range of ethane concentrations, linear elimination pharmacokinetics were observed. n-Pentane, when concentrations higher than 100 ppm were applied, displayed saturation kinetics. These were formally explained by action of two competing metabolizing pathways or enzymes. Application of preexisting models could describe exhalation of both ethane and n-pentane by untreated control rats. Stimulation of lipid peroxidation by ferrous ions or by carbon tetra…
Comparison of isotope ratio mass spectrometry and nondispersive isotope-selective infrared spectroscopy for 13C-urea breath test.
1999
The 13C-urea breath test (UBT) is a sensitive and noninvasive method to diagnose Helicobacter pylori infection, but mass spectrometry (IRMS) is very expensive. The aims of this study were to compare the new low-priced infrared spectroscopy with IRMS in detecting the infection and to assess the influence of feeding on test accuracy.One hundred thirty-four patients with dyspeptic symptoms were recruited. Of these, 74 were infected and 60 uninfected on the basis of both CLO-test and histology. A subgroup of 37 patients (22 H. pylori-positive and 15 H. pylori-negative) was studied under fasting and nonfasting conditions on two different days. Duplicate breath samples were analyzed with two IRMS…
Repeatability of exhaled breath fingerprint collected by a modern sampling system in asthmatic and healthy children
2019
E-noses provide potential non-invasive metabolic biomarkers for diagnosing and monitoring pulmonary diseases. The primary aim of the present study was to assess the within-day and between-day repeatability of a modern breath sampling system (Pneumopipe® plus an array of e-nose sensors) in asthmatic and healthy children. The secondary aim was to compare the repeatability of the breath sampling system, spirometry and exhaled nitric oxide (eNO). Fifteen children (age 6-11 years) with asthma and thirty healthy children matched by age and gender (1:2 allocation) were recruited; of them, three healthy children did not complete the study. All measurements were collected twice during the baseline v…
Effect of nebulized beclomethasone on airway inflammation and clinical status of children with allergic asthma and rhinitis: a randomized, double-bli…
2012
We aimed to evaluate the therapeutic effect of nebulized beclomethasone dipropionate (nBDP) on both allergic asthma and rhinitis. In a randomized, double-blind, placebo-controlled study, 40 children (mean age 10.7 ± 2.1 years) with allergic asthma and rhinitis received either nBDP (daily dose of 800 µg, administered twice daily) or placebo for 4 weeks (with a face mask), after a 2-week run-in period of clinical assessment. Nasal and oral fractional exhaled nitric oxide (FeNO) measurements together with pulmonary function tests, nasal and oral exhaled breath condensate (EBC) collection for pH and interleukin-5 (IL-5) measurements as well as nasal and bronchial symptom scores were obtained at…
The insectivorous batPipistrellus nathusiiuses a mixed-fuel strategy to power autumn migration
2012
In contrast to birds, bats are possibly limited in their capacity to use body fat as an energy source for long migrations. Here, we studied the fuel choice of migratoryPipistrellus nathusii(approximate weight: 8 g) by analysing the stable carbon isotope ratio (δ13CV-PDB) of breath and potential energy sources. Breathδ13CV-PDBwas intermediate betweenδ13CV-PDBof insect prey and adipocyte triacylglycerols, suggesting a mixed-fuel use ofP. nathusiiduring autumn migration. To clarify the origin of oxidized fatty acids, we performed feeding experiments with captiveP. nathusii. After an insect diet, bat breath was enriched in13C relative to the bulk and fat portion of insects, but not deviating fr…
Negative Effect of Ranitidine on The Results of Urea Breath Test for The Diagnosis of Helicobacter Pylori
2001
In analogy with proton pump inhibitors, H2-antagonists may also be responsible for false-negative results on urea breath test for the detection of Helicobacter pylori. In this study we assessed the frequency and duration of false-negative urea breath tests in patients given different doses of ranitidine.A total of 120 consecutive dyspeptic patients infected with H. pylori on the basis of concomitant positive results of CLO-test, histology and urea breath test were recruited for this prospective, open, parallel-group study performed in an urban university gastroenterological clinic. They were randomized to receive an acute treatment with either ranitidine 300 mg once a day in the evening, ra…
Hydrogen- and Methane-Based Breath Testing and Outcomes in Patients With Heart Failure
2019
Background: Recent evidence endorses gut microbiota dysregulation in the pathophysiology of heart failure (HF). Small intestinal bacterial overgrowth (SIBO) might be present in HF and associated with poor clinical outcomes. Lactulose breath testing is a simple noninvasive test that has been advocated as a reliable indicator of SIBO. In patients with HF, we aimed to evaluate the association with clinical outcomes of the exhaled hydrogen (H-2) and methane (CH4) concentrations through the lactulose breath test. Methods and Results: We included 102 patients with HF in which lactulose SIBO breath tests were assessed. Cumulative gas was quantified by the area under the receiver operating characte…
A nanomaterial-based breath test for distinguishing gastric cancer from benign gastric conditions
2013
Background: Upper digestive endoscopy with biopsy and histopathological evaluation of the biopsy material is the standard method for diagnosing gastric cancer (GC). However, this procedure may not be widely available for screening in the developing world, whereas in developed countries endoscopy is frequently used without major clinical gain. There is a high demand for a simple and non-invasive test for selecting the individuals at increased risk that should undergo the endoscopic examination. Here, we studied the feasibility of a nanomaterial-based breath test for identifying GC among patients with gastric complaints. Methods: Alveolar exhaled breath samples from 130 patients with gastric …
Porous materials applied to biomarker sensing in exhaled breath for monitoring and detecting non-invasive pathologies
2020
International audience; Overview of the use of porous materials for gas sensing to analyze the exhaled breath of patients for disease identification.The quantification of specific gases among thousand of VOCs (Volatile Organic Compounds) present in the human breath at the ppm/ppb level can be used to evidence the presence of diseases in the human body. The detection of these biomarkers in human exhaled breath through a noninvasive approach is an important field of research which is still attracting important attention to this day. A portable device working at room temperature and usable directly on exhaled breath samples is still a challenge requiring a sensing material with high performanc…
Breath testing as a method for detecting lung cancer
2014
Early diagnosis of lung cancer is important due to high mortality in late stages of the disease. An ideal approach for population screening could be the breath analysis, due to its non-invasiveness, simplicity and cheapness. Using sensitive methods of analysis like gas chromatography/mass spectrometry in exhaled air of cancer patients were discovered some volatile organic compounds - possible candidates for cancer markers. However, these compounds were not specific for cancer cells. At the same time, integrative approaches used to analyze the exhaled breath have demonstrated high sensitivity and specificity of this method for lung cancer diagnosis. Such integrative approaches include detect…