Search results for "Bronchography"
showing 5 items of 5 documents
Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size
1999
Objectives: To determine whether individualized selection of double-lumen tubes or alternatives based on three-dimensional reconstruction of the tracheobronchial image from routine preoperative computed tomography (CT) scans leads to clinically appropriate choices. Design: Prospective observational study; comparison to historic controls. Setting: Anesthesia and radiology facilities of a university medical center. Participants: Forty-nine patients undergoing thoracic surgery requiring one-lung ventilation. Interventions: Three-dimensional image reconstruction of individual tracheobronchial anatomy was performed from routine preoperative spiral CT scans as well as from scans of five left-side…
Influence of pixel size on quantification of airway wall thickness in computed tomography.
2009
Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multidetector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes …
Three-dimensional helical CT of the tracheobronchial tree: evaluation of imaging protocols and assessment of suspected stenoses with bronchoscopic co…
1996
To assess the accuracy of three-dimensional (3D) helical CT of normal airways, we evaluated different imaging protocols in test objects and patients. The clinical value of 3D helical CT was composed with bronchoscopy in patients with suspected stenoses, especially before and after endobronchial procedures.Solid test objects--one of central airways and one of peripheral airways--were scanned and assessed for volume defects and stairstep artifacts. Fifty helical studies were performed in 36 patients. We evaluated these images for visualization of segmental bronchi; frequency of artifacts; and presence, localization, and degree of stenoses. Bronchoscopic correlation was available for 40 CT exa…
Reply: Air Bronchogram Is Not Specific for Pneumonia.
2016
IF 13.118; International audience
About Objective 3-D Analysis of Airway Geometry in Computerized Tomography
2008
The technology of multislice X-ray computed tomography (MSCT) provides volume data sets with approximately isotropic resolution, which permits a noninvasive 3-D measurement and quantification of airway geometry. In different diseases, like emphysema, chronic obstructive pulmonary disease (COPD), or cystic fribrosis, changes in lung parenchyma are associated with an increase in airway wall thickness. In this paper, we describe an objective measuring method of the airway geometry in the 3-D space. The limited spatial resolution of clinical CT scanners in comparison to thin structures like airway walls causes difficulties in the measurement of the density and the thickness of these structures.…