Comparison of the ventilating and injection bronchoscopes.
1973
Gastric insufflation pressure, air leakage and respiratory mechanics in the use of the laryngeal mask airway (LMA) in children.
2004
Summary Background : The objective of the present study was to evaluate the prelaryngeal position of the laryngeal mask airway (LMATM) in children, and to determine the influence of mask positioning on gastric insufflation and oropharyngeal air leakage. Methods : A total of 100 children, 3–11 years old, scheduled for surgical procedures in the supine position under general anaesthesia were studied. After clinically satisfactory LMA placement, tidal volumes were increased stepwise until air entered the stomach, airway pressure exceeded 30 cmH2O, or air leakage from the mask seal prevented further increases in tidal volume. LMA position in relation to the laryngeal entrance was verified using…
Easy removal of a large mucus plug with a flexible paediatric bronchoscope after administration of rhDNase (Pulmozyme).
2006
Mucoid impaction and plastic bronchitis are relatively rare disorders affecting patients of any age. Here we report the case of mucoid impaction developing in a four-year-old child as a complication of pneumonic infection treated four weeks prior. p.a. chest X-ray and fiberoptic bronchoscopy showed atelectasis and the location of a mucus cast in the left upper lobe. After extraction of the cast via the suction channel of the bronchoscope had failed, we administered 2.5 mg of undiluted recombinant human deoxyribonuclease (rhDNase) instilled directly over the affected area of occlusion for 15 minutes. This mucolytic agent mobilized the cast by reducing viscoelasticity and adherence of mucus. …
Transesophageal Endobronchial Ultrasound-Guided Fine-Needle Aspiration
2011
The ultra-thin bronchoscope in management of the difficult paediatric airway
1987
The use of an ultra-thin flexible fiberoptic bronchoscope with a single lumen diameter of 2.7 mm at the distal tip to assist intubation of paediatric patients with a difficult airway is reported. Two patients (ages 30 months and 18 months) with mandibular hypoplasia and one patient (three months) with the Pierre-Robin syndrome are reported. In each case two fiberoptic bronchoscopes were used. The first allowed introduction of topical local anaesthetic while the second and smaller one was used for tube placement.
Laryngeal Mask Airway Position and the Risk of Gastric Insufflation
1998
A potential risk of the laryngeal mask airway (LMA) is an incomplete mask seal causing gastric insufflation or oropharyngeal air leakage.The objective of the present study was to assess the incidence of LMA malpositions by fiberoptic laryngoscopy, and to determine their influence on gastric insufflation and oropharyngeal air leakage. One hundred eight patients were studied after the induction of anesthesia, before any surgical manipulations. After clinically satisfactory LMA placement, tidal volumes were increased stepwise until air entered the stomach, airway pressure exceeded 40 cm H2 O, or air leakage from the mask seal prevented further increases in tidal volume. LMA position in relatio…