Empirical BAC factors method application to two real case studies in South Italy
2021
Abstract The application of Building Automation and Control (BAC) systems has many advantages. One of these is the reduction of the end-user electricity consumption and, if applied to lighting systems, the achievement of well-acknowledged benefits from daylight, such as productivity, health, visual comfort and well-being. Concerning the first aspect, the international Standard EN 15232 proposes the so-called BAC Factors (BF) method to assess the impact of BAC systems on the final energy consumption. The method provides a simplified estimation of the energy savings due to automation in buildings and questions arise on its applicability in some situations. For this reason, the authors have ca…
L'oppidum arverne de Gondole (Le Cendre, Puy-de-Dôme).
2009
Optimal Design of Grid Integration of a Net Zero Energy Building trough Electrochemical Energy Storage and Fuel Cell Utilization
2018
The integration of electrochemical energy storage, renewable energy production, and fuel cell systems can play a key role in the development of more efficient eco-friendly systems, spanning all sectors of energy management, from stationary to mobile. In particular, residential sector consumed 19% of worldwide energy production in 2015, resulting the third energivorous sector after transport and industry. Distributed energy systems, which efficiently use local resources, can reduce problems in regions with lack of a stable network and more in general help the growth of a sustainable development. In this case, the impact of PV-Lithium Batteries-SOFC integration in a NZEB (Net Zero Energy Buil…
Assessing the Effect of Microclimate on Building Energy Performance by Co-Simulation
2011
To provide a more accurate prediction of building energy consumption, it is necessary to take into account the influence of the microclimate around a building establishing through the interaction with other buildings or the natural environment. This paper presents a method for the quantitative assessment of building performance under any given urban context by linking the urban microclimate model ENVI-met to the building energy simulation (BES) program EnergyPlus. The full microclimatic factors such as solar radiation, thermal radiation, outdoor air temperature, humidity, and wind speed have been considered in the proposed scheme. The method outlined in this paper could be useful for urban …
Hybrid Passive Control Strategies for Reducing the Displacements at the Base of Seismic Isolated Structures
2019
In this paper, the use of hybrid passive control strategies to mitigate the seismic response of a base-isolated structure is examined. The control performance of three different types of devices used for reducing base displacements of isolated buildings is investigated. Specifically, the Tuned Mass Damper (TMD), the New Tuned Mass Damper (New TMD) and the Tuned Liquid Column Damper (TLCD), each one associated to a Base Isolated structure (BI), have been considered. The seismic induced vibration control of base-isolated structures equipped with the TMD, New TMD or the TLCD is examined and compared with that of the base-isolated system without devices, using real recorded seismic signals as e…
Assessment of the tuned mass damper inerter for seismic response control of base‐isolated structures
2020
In this paper, the hybrid control of structures subjected to seismic excitation by means of tuned mass damper inerter (TMDI) and base-isolation subsystems is studied with the aim of improving the dynamic performance of base-isolated structures by reducing the displacement demand of the isolation subsystem. The seismic performance of TMDI hybrid controlled structures is investigated in a comparative study, considering simple isolated systems and systems equipped with other absorber devices such as the tuned mass damper (TMD) and the tuned liquid column damper (TLCD). The TMDI has been optimized by performing a simplified approach based on minimizing the base-isolation subsystem displacement …
Scope Oriented Thermoeconomic analysis of energy systems. Part II: Formation Structure of Optimality for robust design
2010
This paper represents the Part II of a paper in two parts. In Part I the fundamentals of Scope Oriented Thermoeconomics have been introduced, showing a scarce potential for the cost accounting of existing plants; in this Part II the same concepts are applied to the optimization of a small set of design variables for a vapour compression chiller. The method overcomes the limit of most conventional optimization techniques, which are usually based on hermetic algorithms not enabling the energy analyst to recognize all the margins for improvement. The Scope Oriented Thermoeconomic optimization allows us to disassemble the optimization process, thus recognizing the Formation Structure of Optimal…
Optimal design of CHCP plants in the civil sector by Thermoeconomics
2007
The optimization of design and operation of trigeneration plants for civil applications is a very complex task, because of the large number of internal and external variables affecting the energetic and economic results that may be achieved. Further, energy-saving and profit-oriented optimization processes usually lead to different solutions, in terms of plant lay-out, optimal size of components and operation strategy. Thermoeconomic methodologies are very effective theoretical structures for the optimization of industrial energy-systems characterised by regular energy-demand profiles; however, they are hard to use when approaching civil applications and energy systems in unsteady operating…
Optimal design of complex passive-damping systems for vibration control of large structures: An energy-to-peak approach
2014
Published version of an article in the journal: Abstract and Applied Analysis. Also available from the publisher at: http://dx.doi.org/10.1155/2014/510236 Open Access We present a new design strategy that makes it possible to synthesize decentralized output-feedback controllers by solving two successive optimization problems with linear matrix inequality (LMI) constraints. In the initial LMI optimization problem, two auxiliary elements are computed: a standard state-feedback controller, which can be taken as a reference in the performance assessment, and a matrix that facilitates a proper definition of the main LMI optimization problem. Next, by solving the second optimization problem, the …
Multicriteria-Oriented Optimization of Building Energy Performances: The Annex 72 IEA-EBC Experience
2021
International audience; This chapter describes the research experience of the International Energy Agency-Energy in Buildings and Communities Programme Annex 72 members on the application of multi-objective optimization processes for the selection of design or retrofit actions that allow for improving different aspects (energy, environmental, economic, etc.) of buildings in a life cycle perspective. Thirteen case studies were examined focussing on methodologies, applications and results and deriving generic conclusions and guidelines for building designers and decision-makers.