Architecture in iron in the city of XIX century Roof structures of theatres and covered markets in Palermo
2016
In post-unification Palermo, components manufactured abroad were usually used for complementary iron structures (greenhouses and skylights, projecting roofs, staircases…), whereas, for more demanding works, more weight was given to the contribution of producers with experience gained in the field of metal construction. Analysis is here carried out on the works of greatest importance, from the roofs of the two major theatres to the roofing of food market structures; the finest technicians were employed and a critical debate was triggered in the city with regard to formal, static and building aspects.
Strategies, Technologies and Novel Components for the Architectural Integration of Photovoltaics
2015
La ricerca riguarda l'integrazione architettonica del fotovoltaico (FV) per il retrofit energetico del patrimonio edilizio esistente e la costruzione di edifici a energia zero (ZEB). L'obiettivo è lo studio e la successiva definizione di strategie, tecnologie e componenti innovativi per l'involucro edilizio che integrino il fotovoltaico, con particolare attenzione verso le tecnologie fotovoltaiche di nuova generazione. Il lavoro si concentra anche sull'ottimizzazione energetica e sull'analisi delle prestazioni di un componente innovativo per il BIPV (Building Integrated Photovoltaics, letteralmente fotovoltaico integrato negli edifici) utile alla costruzione di involucri edilizi sostenibili…
The assessment of the reliability of an innovative 3rd generation solar cell integrated with “thermal belt” glass block
2017
Glass block is a building product widely used for the construction of translucent building façades and roofs. The need to adapt the product to the regulations in the field of energy saving and environmental sustainability has led to the design of innovative configurations, through the integration of different sub-components. These ones are able to improve its energy performance by means of the integration of a“thermal belt”, cold glued to the glass shells, which constitute the traditional glass block, and 3rd generation solar cells. This paper reports the first results of the experimental program designed to assess some durability components: inherent and critical reliability. <div id="g…
Sequestrati dalla vendetta: “rimanere chiusi fuori dall’oggetto”
2013
RiassuntoA partire dal loro lavoro di psicoterapeute e attraverso alcuni frammenti clinici che si riferiscono ad un gruppo di adolescenti svoltosi in un quartiere a rischio di Palermo, le Autrici analizzano la dimensione mafiosa non restringendola al solo comportamento criminale; piuttosto declinandola lungo alcuni significanti: non identità e gruppo mafioso che colonizza e sottomette lo psichismo del singolo; fantasmi familiari potenti e spietati che impediscono il costituirsi di sé originali e autonomi; personalità impastate di indifferenza emotiva e vendicatività. Significanti che rendono conto delle vaste aree di desertificazione e pietrificazione – resistenza al cambiamento – avvertita…
Hygrothermal conditions in Cross Laminated Timber (CLT) dwellings
2020
The use of CLT has been increasing the last decade, and a subsequently focus on documentation of the accompanying indoor climate and exposed wooden surfaces on human well-being. This study presents the results of a measurement campaign conducted over one year of a CLT apartment building in Grimstad, Norway. The apartment building consists of three floors with 35 apartments and comply with the Norwegian passive house standard and energy grade A. Measurements of the relative humidity (RH), indoor air temperature and wood moisture content (MC) were performed in the exposed CLT spruce panels in three apartments in two different floors. The results from the three apartments show a relatively sma…
A study of solar panel efficiency in Latvian climate conditions
2020
With solar panels increasingly used in nearly zero energy building solutions it is important to clarify if the panels can achieve the efficiency indicators specified by their producers in real operation conditions. To determine the efficiency of poly- and monocrystalline panels depending on their spatial orientation and the seasons a set of test panels was installed in 2018 in Riga, Latvia for long-term monitoring of the amount of generated power and produced energy. Here we summarize the results of the first year of monitoring. Data indicate that orientation has high significance, very small amounts of energy are generated in autumn/winter and that there is a good correspondence of the act…
The consequences of the inappropriate use of ventilation systems operating in indoor swimming pool conditions - analysis
2018
Increasingly more leisure facilities, such as water parks or indoor swimming pools are being built in Poland nowadays. In order to ensure the air quality required by standards for such leisure facilities it is necessary to fit them with effectively functioning ventilation. For the removal of excess humidity, as well as chlorine ions occurring as a result of the disinfection of water as well as the carbon dioxide emitted by people using the facility, the ventilation system needs to be appropriately designed and efficient. For this reason, studies into the air quality in such facilities were undertaken. The paper presents the causes and consequences of the inappropriate operation and maintena…
Hydro-mechanical behaviour of a sandy silt from a river embankment
2020
The paper presents the results of an experimental campaign aimed at characterizing the hydro-mechanical behaviour of a sandy silt from a river embankment. Due to continuous river level fluctuations and changing climatic and environmental conditions, flood embankment materials experience frequent variations in degree of saturation and suction values. Such variations strongly impact the earthwork performance both in terms of seepage and stability conditions. For these reasons, a detailed characterization of the material behaviour in unsaturated conditions was carried out. Experiments were designed in order to highlight the response of the involved soil in terms of changes in matric suction an…
Evaluating Safety Systems for Machine Tools with Computer Numerical Control using Analytic Hierarchy Process
2019
Computer numerical control (CNC) machine tools are complex production systems with fully automatic machine parts. Nowadays, high feed rates and machining speeds are used during the machining process. Human operators are still needed to set-up the machine, load/unload workpieces and parts, load the machining code, and supervise the machining process. The operators work in an environment where automated high-speed motions occur, and consequently, CNC machine tools have to be equipped with safety systems. The approach presented in this paper was to evaluate the main safety systems of CNC machine tools based upon the analytic hierarchy process (AHP). The analyzed systems were divided into six m…
The valuation error in the compound values
2013
In appraising the “valore di trasformazione” the valuation error is composed by the error on market value and the error on construction cost. In appraising the “valore complementare” the valuation error is composed by the error on market value of complex real property and on market value of the residual part. The final error is a function of the partial errors and it can be studied using estimative and market ratios. The application of the compounds values to real estate appraisal misleads unacceptable errors if carried out with the expertise.