Search results for "Building"
showing 10 items of 1985 documents
RC column externally strengthened with RC jackets
2013
In this paper the behaviour in compression of RC columns externally strengthened with concrete jacketing is analysed and a cross-section analysis of the jacketed member under axial load and bending moment is developed. The focus was to study the effect of confinement of concrete jacket on concrete core and the behaviour of compressed bars with buckling effects. Some other important aspects such as shrinkage, creep, old to new concrete surfaces and bond split effects were not included in the model because: the use of thick non-shrink grout jacket and a well-roughened surface of old-to-new concrete was supposed; long term effects were included though corrective coefficients for monolithic beh…
Effect of FRP Wraps on the Compressive Behaviour of Slender Masonry Columns
2017
In the last decade, Fibre Reinforced Polymer (FRP) wrapping technique has become a common method to retrofit masonry piers or columns with poor structural performances. The passive confinement effect induced by the external wrap allows increasing the compressive strength and ductility of the member. Several studies highlighted as the efficacy of this technique is affected by several key parameters, including the shape of the transverse cross section, stress intensification at the strength corner of sharp sections, amount and mechanical properties of adopted composite. Despite this technique has been widely studied from both theoretical and experimental point of view, most of studies focused…
Experimental performance evaluation of a vapour compression refrigerating plant when replacing R22 with alternative refrigerants
2011
Abstract This paper presents the results of an experimental analysis comparing the performance of a vapour compression refrigerating unit operating with R22, and its performance in comparison to a new HFC fluid, substituting the former according to Regulation No 2037/2000. In particular, the plant working efficiency was first tested with R22 and then with three new HFC fluids: R417A, R422A and R422D. The investigation verified that despite the case of substitution and the advantage of being able to continue to use mineral oil as a lubricant in the compressor, the performance with the new tested fluids did not result as efficient as when using R22.
Minimum bond length and size effects in FRP–substrate bonded joints
2009
Abstract The load transfer mechanism between the fibre-reinforced polymer (FRP) materials and the substrate plays a crucial role in the overall response of retrofitted structural members. The FRP–support material interface can be studied by using pull tests in which a reinforcement plate is bonded to a prism and subjected to a tensile force. The experimental results obtained regard the assembly (FRP strip-support block), then a central problem is how to carry out the interface constitutive laws and the related parameters. The principal objective of the present paper is to contrive a procedure which, for a fixed interface constitutive law, permits to derive the interface mechanical parameter…
A measurement methodology for monitoring a CHCP pilot plant for an office building
2003
Abstract In Mediterranean areas, climate conditions determine quite equal demand both for thermal and cooling energy. The possibility to convert a cooling demand in thermal one through an absorption chiller allows to extend widely the number of running hours of a cogeneration plant. A trigeneration pilot plant for two office building is described, in which an integrated lay-out includes a NG prime mover with heat exchanger, an absorption chiller and a reversible heat pump. The pilot plant is completed and pre-running test were performed. Different fluid dynamics parameters will be monitored, in order to build the actual cumulative curve for thermal power. The measurement methodology is also…
Smart renewable generation for an islanded system. Technical and economic issues of future scenarios
2012
The subject addressed in this paper is the analytical study of the transition of an energy generation system for a real MV/LV distribution system from one that is “fuel-based” to a distributed and smart “renewables-based” system. The paper outlines both the technical and the economic issues related to such a transition from one type of system to the other. The study is carried out for a real islanded network located in the Island of Pantelleria (Mediterranean Sea). The results obtained are presented and discussed, putting into evidence the technical, environmental and economic benefits of using smart technologies and renewable energy sources.
Single thermal zone balance solved by Transfer Function Method
2005
We present an algorithm that uses the Z-transform operator to face the problem of heat transmission in a single thermal zone composed by multilayered walls. The method is very flexible and could be adopted to calculate the transfer function coefficients able to simulate the thermal behaviour of a room in free floating. Knowing the transfer function coefficients, it is possible to simulate the dynamic profile of each inner surfaces temperature and furthermore of the inner air temperature. The proposed algorithm is fully described granting maximum clarity. The explicitness of all steps of the calculus make possible the definition of a method that is able to vary all of the calculus parameters…
A cellular automaton based model simulating HVAC fluid and heat transport in a building. Modeling approach and comparison with experimental results
2010
A discrete model characterizing heat and fluid flow in connection with thermal fluxes in a building is described and tested against experiment in this contribution. The model, based on a cellular automaton approach, relies on a set of a few quite simple rules and parameters in order to simulate the dynamic evolution of temperatures and energy flows in any water or brine based thermal energy distribution network in a building or system. Using an easy-to-record input, such as the instantaneous electrical power demand of the heating or cooling system, our model predicts time varying temperatures in characteristic spots and the related enthalpy flows whose simulation usually requires heavy comp…
Combination of modal responses consistent with seismic input representation
2004
The well-known modal superposition method for the evaluation of seismic response by the complete quadratic modal combination rule (CQC) is revisited. The most widely used version of the CQC rule utilizes correlation coefficients derived for white-noise excitation and neglects the influence of peak factor variation on the response. Here a simplified procedure for evaluation of correlation coefficients and peak factors consistent with the power spectral density of seismic excitation is proposed. The procedure is based on an approximate analytic expression for direct evaluation of the power spectral density of the excitation consistent with any prefixed response spectrum, and the evaluation of…
Applicability of over-coring technique to loaded RC columns
2014
Stress determination is a very important step in the assessment of the safety of existing reinforced concrete structures. In rock mechanic this goal is achieved with the over-coring technique. The main idea behind such a technique is to isolate a material sample from the stress field in the surrounding mass and monitor its re-equilibrium deformation response. If the materials remains elastic, and elastic properties are known, stresses may be obtained from the corresponding measured strains. The goal of this paper is to evaluate if the over-coring technique is applicable to reinforced concrete members. The results of an experimental investigation on the behaviour of compressed concrete colum…