Search results for "Building"
showing 10 items of 1985 documents
Impact analysis of MPL and PEM thickness on temperature distribution within PEFC operating at relatively higher temperature
2020
Abstract In Japan, it is recommended to operate Polymer Electrolyte Fuel Cell (PEFC) at temperature around 90 °C for stationary applications during the period from 2020 to 2025. However, the present PEFC is using Nafion polymer electrolyte membrane (PEM) and operated within the temperature range from 60 °C to 80 °C. It is important to understand the temperature distribution in a cell of PEFC for improving the performance and to realize the long life span. This study focuses on use of micro porous layer (MPL), which can promote the moisture transfer in order to control the temperature distribution. The aim of this study is to analyze the impact of MPL on temperature distribution at reaction …
La dimensione tecnologica del museo: forme, tecniche, "identità mutanti" tra storia e contemporaneità
2005
Nella cultura contemporanea il tema della conservazione dell’eredità storica, della rappresentazione e della trasmissibilità dell’arte è argomento ampiamente dibattuto. La forza culturale del museo, detentore dell’eredità, può essere interpretata secondo diverse traiettorie di forme. La memoria intende esprimersi sulle origini e sul significato della "macchina museale" attraverso l’analisi critica dell’oggetto, sia esso contenitore, palco di rappresentazione o scena interattiva. Sonda i processi di comunicazione relativamente alla forma architettonica, alla funzione ed alla fruizione del prodotto espositivo. Tenendo conto delle diverse scuole di pensiero sulla spettacolarizzazione dell’arte…
Experimental calibration of flat jacks for in-situ testing of masonry
2018
Flat-jack testing method is one of the most commonly used techniques for the structural assessment of existing masonry structures. Single and double flat jacks are usually adopted to evaluate the acting normal stress, or the compressive behaviour of masonry material. Test procedures are codified by international standards (e.g., A.S.T.M D4729-87; C1196-04; C1197-04, R.I.L.E.M TC 177–MDT D.4; R.I.L.E.M. TC 177–MDT D.5), which provide the preliminary calibration of an experimental coefficient (km) and of the effective area (Aeff), which determination influences significantly the reliability of the test. This article presents the result of an experimental study on the calibration of flat jacks…
Comparative Assessment of Mould Growth Risk in Lightweight Insulating Assemblies Via Analysis of Hygrothermal Data and In Situ Evaluation
2019
In order to assess the sustainability of buildings with different types of insulating assemblies in the Latvian climate, a long-term test building monitoring experiment has been underway since 2013. There are a total of five test buildings on site with roughly six years’ worth of accumulated temperature and humidity readings in the key parts of assemblies. This study is meant to quantify the mould presence in building walls, floor and ceiling by performing laboratory tests, assessing the number of colony-forming units, and comparing the results with mould risk predictions due to the isopleth model developed by Sedlbauer, using both the hygrothermal data derived from the sensors within build…
Integrazione di celle solari di terza generazione nel vetromattone per la realizzazione di pannelli traslucidi fotovoltaici. Analisi prestazione e st…
2013
L’articolo illustra i primi risultati ottenuti nell’ambito dell’analisi prestazionale del vetromattone fotovoltaico, un prodotto edilizio innovativo derivato dall’integrazione di celle fotovoltaiche di terza generazione (DSSC) nel vetromattone, ideato per la realizzazione di involucri traslucidi energeticamente effi cienti ed “attivi”, in grado di ridurre i consumi energetici degli edifi ci e di produrre, al contempo, energia verde. L’analisi è stata condotta su quattro differenti ipotesi di integrazione. Attraverso simulazioni numeriche si è effettuata una valutazione dell’energia assorbita dagli strati attivi oltre che delle prestazioni ottiche complessive del dispositivo. Lo studio anali…
Do irresponsible corporate activities prevent membership in sustainable stock indices? The case of the Dow Jones Sustainability Index world
2021
Abstract The study analyses the real-life results from the DJSI World selection process and investigates whether companies are treated differently because of sectoral or geographical diversification needs of the index; furthermore, the question whether its methodology penalises ESG-related irresponsible corporate activities is investigated. The last is an important issue, as it is not unusual to find constituents of sustainable indices implicated in corporate scandals. This is a striking fact, contradicting the ethical and sustainable imperative such companies are supposed to comply with. The authors scrutinise data from a data panel containing 2872 firms between 2011 and 2016 and estimate …
Reti: CIB W78: 32nd international conference in “Information Technology for Construction”, Eindhoven, Netherlands, October 2015
2016
Building Information Modeling (BIM) is an emerging methodology in the building industry, since the intelligent digital three-dimensional model-based process of BIM can be used to plan, design, structure, manage, and analysis buildings. The aim of this report paper is to provide information about the latest related topic in BIM field connecting to CIB W78 conferenece.
Macroelement Model for the Progressive-Collapse Analysis of Infilled Frames
2021
A new multistrut macromodel for the analysis of the progressive-collapse response of infilled reinforced concrete (RC) frames is presented in this paper. The model consists of three struts: two outer infinitely rigid and resistant struts and one inner fiber-section strut. The inclination of the struts as well as the stress-strain response are modulated by two parameters that are obtained by means of analytical correlations provided in the paper. The latter link the geometric and mechanical properties of an infilled frame to the geometric configuration and mechanical response of the equivalent strut model. This confers the model the capability to adapt to consider different collapse configur…
IFC and Buildings Lifecycle Management
2008
International audience; This paper presents an extension of the BIM technology that allows to manage information during the entire lifecycle of an AEC project. Usually, AEC projects and facility management are dissociated. Our building information system plays a central role in the improvement of the design and the management process. The building activity generates a great number of data and information of various kinds. The management and the communication of these data by the various participants is complex. Our design and management methods use IFC files to facilitate the sharing process for a better qualification and validation of data.
Towards a Framework for Building Theory from ISD Practices
2011
The paper presents a framework for building theory from ISD practices. The framework locates ISD practices in a learning loop that is situated in a development context. The framework recognizes that ISD practices are related to their learned rationale that may come from previous experiences, i.e. observed impacts of practices, or from existing theory. These concepts recognized by the framework are needed for building theory from ISD practices, for designing research approaches for studying ISD, for evaluating existing research on ISD practices and for evaluating ISD methods. The framework is also used in the analysis of three recent studies on ISD practices and a discussion about the uses o…