An Improved Load Flow Method for MV Networks Based on LV Load Measurements and Estimations
2019
A novel measurement approach for power-flow analysis in medium-voltage (MV) networks, based on load power measurements at low-voltage level in each secondary substation (SS) and only one voltage measurement at the MV level at primary substation busbars, was proposed by the authors in previous works. In this paper, the method is improved to cover the case of temporary unavailability of load power measurements in some SSs. In particular, a new load power estimation method based on artificial neural networks (ANNs) is proposed. The method uses historical data to train the ANNs and the real-time available measurements to obtain the load estimations. The load-flow algorithm is applied with the e…
A simplified approach for load flow analysis in MV smart grids based on LV power measurements
2017
This paper presents a simplified approach for load flow analysis in medium voltage (MV) distribution networks. It is a power summation Backward/Forward (B/F) algorithm, based on measurements of active and reactive powers at low voltage (LV) side of MV/LV distribution substations. The proposed solution allows achieving good accuracy, computational efficiency and fast convergence. In order to verify the algorithm performances, simulation studies are carried out in the case of a real test system, i.e. the distribution grid of Favignana Island (Mediterranean Sea, Italy). The compatibility between simulations results and power measurements at the MV bus bars of the generating substation shows th…
Secondary substation power line communications for medium voltage smart grids
2012
In this paper a performance analysis is carried out, in order to evaluate the possibility to employ power line communication (PLC) between secondary substations of a medium voltage (MV) distribution networks in a smart grid. The study is focused on the analysis of PLC technologies and the evaluation of the influence quantities on the communication performance in the most common case of by-pass connection at MV bus-bars of secondary substations. Different quantities have been analyzed as modulation techniques, requested bandwidth and bitrate, coupling device and system attenuation versus frequency in order to find the best solution for a reliable communication system. A complete model of a r…
Measurement uncertainty impact on simplified load flow analysis in MV smart grids
2018
This work is focused on the measurement uncertainty impact on load flow analysis in medium voltage (MV) distribution networks. In more detail, the paper presents the uncertainty evaluation of a simplified load flow algorithm, which is based on the load power measurements at each secondary substation and one voltage measurement at the slack bus (i.e. the voltage at the MV bus bars of the primary substation). To reduce the costs of the monitoring system, the load flow algorithm makes use of LV load power measurements for all the substations except those of MV users, where MV transducers are usually already installed. The uncertainties on the algorithm input quantities (load powers and slack b…
Development of integrated superconducting quadrupole doublet modules for operation in the SIS100 accelerator
2015
The FAIR project (Facility for Antiproton and Ion Research) evolves and builds an international accelerator- and experimental facility for basic research activities in various fields of modern physics. Within the course of this project, integrated quadrupole doublet modules are in development. The quadrupole doublet modules provide a pair of superconducting main quadrupoles (focusing and defocusing), corrector magnets, cryogenic collimators and beam position monitors as integrated sets of ion-optical elements. Furthermore LHe cooled beam pipes and vacuum cold-warm transitions are used as ultra-high vacuum components for beam transportation. Superconducting bus bars are used for 13 kA curren…
Economical evaluations of reactive power supply as an ancillary service offered by distributors
2006
Reactive power supply is one of the most important ancillary services in the field of transmission systems safety. In the current market assets, at international level, this service is differently regulated and sometimes with criteria that are not market driven. The present work is focused on the perspective to realise a reactive power market to which also the distributors can take part injecting reactive power into HV/MV connection bus bar. Under this hypothesis, the paper proposes a methodology to evaluate the economic convenience limits that the system operator would have buying the capacitive reactive power offered by distributors.
Power Bus Management Techniques for Space Missions in Low Earth Orbit
2021
In space vehicles, the typical configurations for the Solar Array Power Regulators in charge of managing power transfer from the solar array to the power bus are quite different from the corresponding devices in use for terrestrial applications. A thorough analysis is reported for the most popular approaches, namely Sequential Switching Shunt Regulation and parallel-input Pulse Width Modulated converters with Maximum Power Point Tracking. Their performance is compared with reference to a typical mission in low Earth orbit, highlighting the respective strengths and weaknesses. A novel solar array managing technique, the Sequential Maximum Power Tracking, is also introduced in the trade-off a…
Distributed optimal power flow for islanded microgrids: An application to the Smart Polygeneration Microgrid of the Genoa University
2016
In this work, the application of an original distributed optimal power flow method to test a microgrid in the Savona area, Italy is proposed. The microgrid shows different types of Distributed Energy Resources (DERs) and is connected to the main grid through a fixed power bus. Due to the high computational speed, the applied distributed Optimal Power Flow can be performed almost in real time, i.e. every 5 minutes or less. The operating solution found for generators, simply using local information, corresponds to a suboptimal condition with reduced losses, bus voltages and line currents within constrained intervals. The distributed optimization algorithm is iterative, but also fast. It is ba…