Search results for "CAMERA"
showing 10 items of 290 documents
BALDONE OBSERVATORY IN THE CIRCLES OF TIME
2019
1957 – The first laboratory building, known as the White House, was built near Baldone on the Riekstu hill, in the territory of the next Observatory. 01.01.1958 – The Astronomy Sector was separated from the Institute of Physics and commenced independent activi- ty as the Laboratory of Astrophysics at the Latvian Acade- my of Sciences (LAS). In 1967, with the decision of the Presidium of the Latvian SSR LAS the Laboratory of As- trophysics was transformed into the Radioastrophysic Ob- servatory at LAS. Under the leadership of the first director, Janis Ikaunieks, an instrumental observation base develops – a 1.2m Schmidt telescope was installed in 1966 for opti- cal observations. The project …
WiseEye: A Platform to Manage and Experiment on Smart Camera Networks
2016
International audience; Embedded vision is probably at the edge of phenomenal expansion. The smart cameras are embedding some processing units which are more and more powerful. Last decade, high-speed image processing can be implemented on specifically designed architectures [1] nevertheless the designing time of such systems was quite high and time to market therefore as well. Since, powerful chips (i.e System On Chip) and quick prototyping methodologies are contently emerging [2],[3],[4] and enable more complex algorithms to be implemented faster. Moreover, smart cameras which are embedding flexible and powerful multi-core processors or Graphic Processors Unit (GPU) are now available and …
Density and activity patterns of Pallas's cats, Otocolobus manul, in central Mongolia
2021
Abstract Context. The ranges of many small, at-risk felid species occur almost entirely in unprotected areas, where research efforts are minimal; hence data on their density and activity patterns are scare. Aims. We estimated density and activity patterns of Pallas’s cats on unprotected lands in central Mongolia during two periods (May–August and September–November) in 2019. Methods. We used spatially explicit capture–recapture models to estimate population density at 15.2 ± 4.8 individuals per 100 km2. Key results. We obtained 484 Pallas’s cat images from 153 detections during 4266 camera-days. We identified Pallas’s cats using pelage markings and identified 16 individuals from 64 detectio…
Self-calibration of a PTZ Camera Using New LMI Constraints
2013
In this paper, we propose a very reliable and flexible method for self-calibrating rotating and zooming cameras - generally referred to as PTZ (Pan-Tilt-Zoom) cameras. The proposed method employs a Linear Matrix Inequality (LMI) resolution approach and allows extra tunable constraints on the intrinsic parameters to be taken into account during the process of estimating these parameters. Furthermore, the considered constraints are simultaneously enforced in all views rather than in a single reference view. The results of our experiments show that the proposed approach allows for significant improvement in terms of accuracy and robustness when compared against state of the art methods.
3D Reconstruction of Dynamic Vehicles using Sparse 3D-Laser-Scanner and 2D Image Fusion
2016
International audience; Map building becomes one of the most interesting research topic in computer vision field nowadays. To acquire accurate large 3D scene reconstructions, 3D laser scanners are recently developed and widely used. They produce accurate but sparse 3D point clouds of the environments. However, 3D reconstruction of rigidly moving objects along side with the large-scale 3D scene reconstruction is still lack of interest in many researches. To achieve a detailed object-level 3D reconstruction, a single scan of point cloud is insufficient due to their sparsity. For example, traditional Iterative Closest Point (ICP) registration technique or its variances are not accurate and rob…
Single-chain variable fragment (scFv) antibodies against rotavirus NSP4 enterotoxin generated by phage display.
2004
The rotavirus non-structural NSP4 protein causes membrane destabilization as well as an increase in intracellular calcium levels in eukaryotic cells and induces diarrhea in young mice, acting as a viral enterotoxin. In this study the phage display technique was used to generate a panel of single-chain variable fragment (scFv) antibodies specific for the NSP4 protein of the human rotavirus strain Wa from a human semi-synthetic scFv library. After several rounds of panning and selection on NSP4 adsorbed to polystyrene tubes, individual scFv were isolated and characterised by fingerprinting and by sequencing the VH and VL genes. The isolated scFv antibodies specifically recognize NSP4 in enzym…
Gone before its known? Camera-trapping shows alarming levels of putative hybrids in the wildcat (Felis silvestris) population of the Gargano National…
2022
Abstract The European wildcat is a small carnivore widespread across Europe and hybridization with the domestic cat is one of the major threats to wildcats. We estimate the population density of wild-living cats (both wildcats and putative hybrids based on pelage) in the Gargano National Park (Southern Italy). We sampled 20 stations for 540 camera days. We obtained 23 images from 17 detections at 10 cameras, and we identified 10 individuals (6 wildcats and 4 putative hybrids). Population density was estimated at 0.34 ± 0.15 SE wild-living cats/km2. The proportion of putative hybrids indicates an alarming hybridization for this population.
Simple and convenient remote photoplethysmography system for monitoring regional anesthesia effectiveness
2017
Simple and inexpensive remote photoplethysmography system for monitoring the effectiveness of regional anesthesia was developed and tested. The system involves surgical lamp as light source, compact video camera and computer with custom developed software. Data from eight patients were processed and the effectiveness of regional anesthesia was calculated. The results showed that the standard surgical lamp can be used as a light source together with camera for remote monitoring of regional anesthesia effectiveness.
Monitoring SO2 degassing on Stromboli using a permanent UV Camera network
2020
A low-cost multispectral imaging system for the characterisation of soil and small vegetation properties using visible and near-infrared reflectance
2022
Current Proximal Sensing technologies are based on multispectral imaging systems able to capture images in a few spectral bands, usually centred in VIS and NIR regions, to derive vegetation indices. However, most of such systems lack an internal radiometric calibration to estimate the actual reflectance of the observed target, making them sensitive to the local radiative environment and requiring a per-session calibration against a reference target. To overcome such dependence, the instrument described adopts an active illumination of the target surface, allowing the monitoring of soil and low vegetation surfaces by a radiometrically pre-calibrated imaging camera. The system, driven by a mi…