Search results for "CAVI"
showing 10 items of 827 documents
Intraoperative microvascular Doppler monitoring of blood flow within a spinal dural arteriovenous fistula: a precious surgical tool. Case report.
2001
The authors describe a case of spinal arteriovenous fistula (AVF) treated by a microvauscular Doppler–assisted surgical interruption of the arterialized vein. Microvascular Doppler monitoring represents a valid, widely available, non-invasive tool that enables identification, through flow spectrum analysis, of components of this type of vascular malformation. In this case because the location of the fistula was identified prior to opening the dura only minimally invasive surgery was required. Direct recordings of the arterialized draining vein and the nidus of the fistula demonstrated a pathological spectrum caused by the arterial supply and the disturbed venous outflow in which a high-resi…
Marginal integrity of class V restorations: SEM versus dye penetration.
2006
To perform an in vitro investigation on the marginal integrity of different adhesives (Optibond FL, Scotchbond 1XT, Clearfil SE Bond, Adper Prompt L-Pop, S(3) Bond, iBond exp., Adper Prompt L-Pop) in combination with Tetric Ceram as well as an experimental silorane-restorative (Hermes, Hermes Bond; 3M ESPE) using SEM and dye penetration (2% methylene blue) in a comparative manner.Standardized class V-cavities (3 mm x 1.5 mm) were prepared in 70 extracted human teeth (n=10). The adhesives were applied according to manufacturers' instructions. The cavities were restored with three increments. After finishing and polishing (Sof-Lex discs) and thermocycling (5000x, 5/55 degrees C), replicas wer…
Surface debris of canal walls after post space preparation in endodontically treated teeth: A scanning electron microscopic study
2004
Abstract Purpose To evaluate surface cleanliness of root canal walls along post space after endodontic treatment using 2 different irrigant regimens, obturation techniques, and post space preparation for adhesive bonding. Study design Forty teeth, divided into 4 groups, were instrumented, using Ni-Ti rotary files, irrigated with NaOCl or NaOCl + EDTA and obturated with cold lateral condensation (CLC) or warm vertical condensation (WVC) of gutta-percha. After post space preparation, etching, and washing procedure, canal walls were observed using a scanning electron microscope (SEM). Amount of debris, smear layer, sealer/gutta-percha remnants, and visibility of open tubules were rated. Result…
Carbon dioxide diffuse emission and thermal energy release from hydrothermal systems at Copahue-Caviahue Volcanic Complex (Argentina)
2015
Fil: Chiodini, Giovanni. Istituto Nazionale di Geofisica e Vulcanologia, Sezione di Bologna. Bologna, Italia. Fil: Cardellini, Carlo. Università degli Studi di Perugia, Dipartimento di Fisica e Geologia. Perugia, Italy. Fil: Lamberti, María C. Universidad de Buenos Aires. Instituto de Estudios Andinos. Buenos Aires, Argentina. Fil: Agusto, Mariano. Universidad de Buenos Aires. Instituto de Estudios Andinos. Buenos Aires, Argentina. Fil: Caselli, Alberto Tomás Universidad Nacional de Río Negro. Instituto de Investigación en Paleobiología y Geología. Río Negro. Argentina. Fil: Liccioli, Caterina. Universidad de Buenos Aires. Instituto de Estudios Andinos. Buenos Aires, Argentina. Fil: Tambure…
Impairment of leaf hydraulics in young plants of Citrus aurantium (sour orange) infected by Phoma tracheiphila.
2007
Phoma trachephila (Petri) Kantschaveli et Gikachvili causes dieback of several Citrus species. The impact of this fungus on leaf hydraulics was studied in Citrus aurantium L. (sour orange) with the aim of identifying the primary mechanism of damage to leaves. Leaves inoculated with a conidial suspension were measured for conductance to water vapor (gL) and specific hydraulic conductance (Kleaf) every 3 days after inoculation. The earliest symptom of infection consisted of vein chlorosis. Functional vein density (FVD) was monitored and microscopic observations were made of major vein conduits. Impairment of vein hydraulics started 25 days after inoculation with a losses of Kleaf of 40% and g…
A Novel Technique for Deembeding the Unloaded Resonance Frequency from Measurements of Microwave Cavities
2006
[EN] A novel technique to extract the influence of coupling networks on the resonant frequency of cavities in one-port measurements is presented. The determination of the unloaded resonant frequency is performed directly from measurements without either the need to obtain the electromagnetic fields in the resonator or to deembed the delay of transmission lines from the measuring equipment to the resonator. The importance of the Foster's form on the modeling of the frequency detuning of the resonators is also discussed and a criterion for the choice of the appropriate Foster's form is suggested. The procedure is validated with simulations and experimental measurements of manufactured cavities
A new empirical method for extracting unloaded resonant frequencies from microwave resonant cavities
2003
Equivalent circuits traditionally used to model resonators and coupling networks in the vicinity of a resonance provide values of unloaded resonant frequencies which usually do not agree with experimental results. A new empirical method for the extraction of influence of coupling networks on resonant cavities is presented. The characterization of coupling structures is performed directly from measurements without the need of obtaining the electromagnetic fields inside the cavity, which is very interesting from a practical point of view. Results are validated with simulations and experimental measurements. The accuracy of some cavity applications, such as dielectric characterization techniqu…
Spontaneous emission of an atom near an oscillating mirror
2019
We investigate the spontaneous emission of one atom placed near an oscillating reflecting plate. We consider the atom modeled as a two-level system, interacting with the quantum electromagnetic field in the vacuum state, in the presence of the oscillating mirror. We suppose that the plate oscillates adiabatically, so that the time-dependence of the interaction Hamiltonian is entirely enclosed in the time-dependent mode functions, satisfying the boundary conditions at the plate surface, at any given time. Using time-dependent perturbation theory, we evaluate the transition rate to the ground-state of the atom, and show that it depends on the time-dependent atom-plate distance. We also show t…
Quasi-Normal Frequencies in Open Cavities: An Application to Photonic Crystals
2005
The electromagnetic field in an optical open cavity is analyzed in the framework of the Quasi-Normal Modes theory. The role of the complex quasi-normal frequencies in the transmission coefficient and their link with the density of quasi-modes function is clarified. An application to a quarter-wave symmetric one-dimensional photonic crystals is discussed to illustrate the usefulness and the meaning of our results.
Field fluctuations near a conducting plate and Casimir-Polder forces in the presence of boundary conditions
2006
We consider vacuum fluctuations of the quantum electromagnetic field in the presence of an infinite and perfectly conducting plate. We evaluate how the change of vacuum fluctuations due to the plate modifies the Casimir-Polder potential between two atoms placed near the plate. We use two different methods to evaluate the Casimir-Polder potential in the presence of the plate. They also give new insights on the role of boundary conditions in the Casimir-Polder interatomic potential, as well as indications for possible generalizations to more complicated boundary conditions.