Search results for "CDT"
showing 10 items of 32 documents
Improved electroless platinum contacts on CdZnTe X- and γ-rays detectors
2020
AbstractPlatinum is a promising candidate for the realization of blocking electrical contacts on cadmium-zinc-telluride (CdZnTe or CZT) radiation detectors. However, the poor mechanical adhesion of this metal often shortens the lifetime of the final device. In this work, a simple and effective procedure to obtain robust platinum contacts by electroless deposition is presented. Microscopical analysis revealed the final thickness and composition of the contact layer and its adhesion to the bulk crystal. The blocking nature of the Pt-CdZnTe junction, essential to obtain low noise devices, was confirmed by current–voltage measurements. The planar Pt-CdZnTe-Pt detectors showed good room temperat…
1q gain and CDT2 overexpression underlie an aggressive and highly proliferative form of Ewing sarcoma
2012
12 páginas, 6 figuras, 1 tabla.-- et al.
Development of a 3D CZT detector prototype for Laue Lens telescope
2010
We report on the development of a 3D position sensitive prototype suitable as focal plane detector for Laue lens telescope. The basic sensitive unit is a drift strip detector based on a CZT crystal, (similar to 19x8 mm(2) area, 2.4 mm thick), irradiated transversally to the electric field direction. The anode side is segmented in 64 strips, that divide the crystal in 8 independent sensor (pixel), each composed by one collecting strip and 7 (one in common) adjacent drift strips. The drift strips are biased by a voltage divider, whereas the anode strips are held at ground. Furthermore, the cathode is divided in 4 horizontal strips for the reconstruction of the third interaction position coord…
Experimental results from Al/p-CdTe/Pt X-ray detectors
2013
Recently, Al/CdTe/Pt detectors have been proposed for the development of high resolution X-ray spectrometers. Due to the low leakage currents, these detectors allow high electric fields and the pixellization of anodes with the possibility to realize single charge carrier sensing detectors. In this work, we report on the results of electrical and spectroscopic investigations on CdTe diode detectors with Al/CdTe/Pt electrode configuration (4.1×4.1×0.75 and 4.1×4.1×2 mm3). The detectors are characterized by very low leakage currents in the reverse bias operation: 0.3 nA at 25 °C and 2.4 pA at -25 °C under a bias voltage of -1000 V. The spectroscopic performance of the detectors at both low and…
The DNA-binding subunit p140 of replication factor C is upregulated in cycling cells and associates with G 1 phase cell cycle regulatory proteins
1999
The DNA-binding subunit of replication factor C (RFCp140) plays an important role in both DNA replication and DNA repair. The mechanisms regulating activation of RFCp140 thereby controlling replication and cellular proliferation are largely unknown. We analyzed protein expression of RFCp140 during cell cycle progression and investigated the association of RFCp140 with cell cycle regulatory proteins in cell lines of various tissue origin and in primary hematopoietic cells. Western and Northern blot analyses of RFCp140 from synchronized cells showed downregulation of RFCp140 when cells enter a G0-like quiescent state and upregulation of RFCp140 in cycling cells. Translocation from the cytopla…
Escherichia coli cytolethal distending toxin blocks the HeLa cell cycle at the G2/M transition by preventing cdc2 protein kinase dephosphorylation an…
1997
Cytolethal distending toxins (CDT) constitute an emerging heterogeneous family of bacterial toxins whose common biological property is to inhibit the proliferation of cells in culture by blocking their cycle at G2/M phase. In this study, we investigated the molecular mechanisms underlying the block caused by CDT from Escherichia coli on synchronized HeLa cell cultures. To this end, we studied specifically the behavior of the two subunits of the complex that determines entry into mitosis, i.e., cyclin B1, the regulatory unit, and cdc2 protein kinase, the catalytic unit. We thus demonstrate that CDT causes cell accumulation in G2 and not in M, that it does not slow the progression of cells th…
Factors associated with mild cognitive impairment in a population-based cohort
2017
Il lavoro non prevede abstract
CdTe Detectors
2014
Cadmium telluride (CdTe) compound semiconductors for x-ray detectors have experienced a rather rapid development in the last few years, due to their appealing performance. In this chapter we review the physical properties of semiconductor detectors for x-ray and γ ray spectroscopy. In particular, we focus on compound semiconductor detectors. We also review the principles of operation of both the semiconductor detectors and the electronic chains, with special emphasis on the digital techniques. CdTe detectors’ characteristics and performance enhancements are discussed in depth. Finally, we present some original results on CdTe detectors for medical applications.
CdTe Nanocrystal Synthesis in SiO 2 /Si Ion‐Track Template: The Study of Electronic and Structural Properties
2020
Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy.
2006
We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detecto…