Search results for "CEDU"
showing 10 items of 2453 documents
Patients with acute chest pain, elevated troponin and normal coronary arteries, could be the Cardiovascular Magnetic Resonance advantageous?
2013
Langzeitverlauf über 10 Jahre nach Ballondilatation bei stabiler und instabiler Angina pectoris
2008
OBJECTIVE To assess the cardiac status of patients ten years after percutaneous transluminal coronary artery angioplasty (PTCA). PATIENTS AND METHODS Data of 534 patients (436 men, 98 women; mean age 53.2 +/- 8 years) in whom a PTCA had been performed between 1983 and 1986 were analysed, based on a questionnaire answered 121 +/- 11 months after the initial procedure. At the time of PTCA 184 patients (35%) had unstable angina, 350 (65%) stable angina. RESULTS 116 patients (63%) with unstable angina and 164 (47%) with stable angina had at least one cardiac event after the initial PTCA (repeat PTCA, bypass operation, myocardial infarction, death). None of these events occurred in 68 patients (…
The interaction between circadian rhythms of endothelial function: resting versus recruitable endothelial function
2013
Algunas reflexiones acerca de la stjue de 9 de julio de 2020 sobre los pactos novatorios en materia de cláusulas suelo
2021
The Sentence of the Court of Justice of the European Union of July 9, 2020 comes to answer the five questions that, in its preliminary question, the Court of First Instance and Instruction No. 3 of Teruel asks about the validity of the new agreements in the context of the floor clauses, establishing jurisprudential doctrine on this matter about which our Supreme Court had previously ruled in its Judgments of October 16, 2017, in the sense of considering the agreed floor clause null as a consequence of the novation agreement and, subsequently, those of April 11, 2018 and September 13, 2018 in the opposite direction, declaring that the novation agreement was valid. It is a long-awaited and in…
External stenting with a new polyester mesh reduces neointimal hyperplasia of vein grafts in a sheep model.
2007
Objective External stents placed around vein grafts have demonstrated effectiveness in reducing neointimal hyperplasia by preventing distension of the thin-walled vein grafts when exposed to arterial pressure. However, the ideal stent material has yet to be defined. The following study investigates the short- and long-term effects of an innovative polyester mesh stent designed with optimized adaptation of circumferential compliance. Methods Following in vitro definition of the ideal macro-porous polyester stent material, a total of 12 sheep underwent implantation of bilateral carotid artery vein graft bypasses. In six sheep, the short-term outcome (four weeks of implantation) was investigat…
Implantation of a polycaprolactone scaffold with subchondral bone anchoring ameliorates nodules formation and other tissue alterations
2015
Purpose: Articular cartilage has limited repair capacity. Two different implant devices for articular cartilage regeneration were tested in vivo in a sheep model to evaluate the effect of subchondral bone anchoring for tissue repair. Methods: The implants were placed with press-fit technique in a cartilage defect after microfracture surgery in the femoral condyle of the knee joint of the sheep and histologic and mechanical evaluation was done 4.5 months later. The first group consisted of a biodegradable polycaprolactone (PCL) scaffold with double porosity. The second test group consisted of a PCL scaffold attached to a poly(L-lactic acid) (PLLA) pin anchored to the subchondral bone. Result…
Under Pressure: Comparison of Aspiration Techniques for Endovascular Mechanical Thrombectomy.
2018
BACKGROUND AND PURPOSE: Blood flow should be interrupted during mechanical thrombectomy to prevent embolization of clot fragments. The purpose of our study was to provide a handy overview of the most common aspiration devices and to quantify their flow characteristics. MATERIALS AND METHODS: We assessed volumetric flow rates generated by a 60-mL VacLok vacuum pressure syringe, a Pump MAX aspiration pump, and a Dominant Flex suction pump connected to the following: 1) an 8F long sheath, 2) an 8F balloon-guide catheter, 3) an ACE 64 distal aspiration catheter, and 4) an AXS Catalyst 6 Distal Access Catheter. We used a water/glycerol solution, which was kept at a constant temperature of 20°C (…
L'Europa dopo Lisbona: cosa cambia
2010
Sommario: 1. Un primo, sintetico, quadro generale; 2. Due Corti a confronto; 2.1 Storia, competenze ed ambito d’azione della Corte di giustizia; 2.1.1 Quali novità nel sistema giudiziario europeo dopo l’entrata in vigore del Trattato di Lisbona? Una panoramica; 2.2 Il funzionamento della Corte europea dei diritti dell’uomo;3. I rapporti tra le Corti sul piano interpretativo; 4. Interazione tra Carta dei diritti fondamentali e Convenzione all’indomani dell’adesione dell’Unione alla CEDU; 5. Un nuovo scenario su cui riflettere: l’esecuzione delle sentenze in caso di condanna dell’Unione; 6. Gli Stati e il problema della doppia appartenenza: lo “spartiacque” Lisbona; 7. Nelle maglie della “ret…
Esperienze finalizzate alla gestione conservativa dei boschi di faggio in Sicilia
2009
Con riferimento ai boschi di faggio del Parco naturale dei Nebrodi, in Sicilia, vengono esposti i risultati di un particolare intervento di conversione di un ceduo in fustaia. Il metodo prescelto è quello della matricinatura intensiva con rilascio del materiale di risulta triturato sul posto.
Polyphosphate, the physiological metabolic fuel for corneal cells: a potential biomaterial for ocular surface repair
2019
The regeneration of the epithelium, covering the avascular cornea, involves the processes of differentiation, proliferation and migration of cells originating from the corneal epithelial stem cells. We ask the question if these energy-consuming processes can be fueled by the physiological, inorganic polyphosphate (polyP), the main energy storage/donor molecule in the extracellular space. The ex vivo results reveal that addition of polyP, in the form of soluble Na-polyP, to the culture medium elicits a strong stimulatory effect on cell viability/growth and migration of corneal epithelial cells. Microscopic analyses of partially denuded cornea specimens show that in the presence of polyP, but…