nEDM experiment at PSI : data-taking strategy and sensitivity of the dataset
2018
We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and shaped by a series of precision field coils. In addition to details of the setup itself, we describe the chosen path to realize an appropriate balance between achieving the highest statistical sensitivity alongside the necessary control on systematic effects. The resulting irreducible sensitivity is …
Spatial distribution of air kerma rate and impact of accelerating voltage on the quality of an ultra soft X-ray beam generated by a cold cathode tube…
2015
Abstract Ultrasoft X-ray characteristic aluminum K alpha line (Al Kα with energy of 1.5 keV) is used in radiobiological experiments to study the effect of radiation on biological matter. A simple method to generate a continuous beam of those X-ray radiations is to bombarding an aluminum target with accelerated electrons using high voltage (HV). In this work, by varying the HV we study the characteristics of a photon beam generated by means of a cold cathode transmission X-ray tube. The anode is a thin (16 μm) aluminum foil supported by a copper grid. The spatial distribution of air kerma is measured using gafchromic films of HD-810 calibrated with a parallel plate free-air ionization chambe…
SU-E-T-218: Octavius 4D: Commissioning and Clinical Implementation of a New Device for VMAT Verifications
2013
Purpose: To commission a new device for pre‐treatment patient specific verification of VMAT plans, which is capable of reconstructing 3D dose with high resolution. Methods: Octavius 4D system (PTW) consists of an ion chamber array embedded in a cylindrical phantom which, assisted by an inclinometer, rotates synchronously with the gantry. For VMAT plans, it measures planar dose distributions as a function of gantry angle in order to compute the resulting 3D dose distribution. There are two options for the ion chamber array: Octavius 729 (general purpose) and Octavius 1000 SRS (small field size, high resolution). We have used three linacs: two Varian Clinac iX and one TrueBeam with MLC HD 120…
Improved measurement of theB 0 andB + meson lifetimes
1996
The lifetimes of the B 0 and B + mesons have been measured with the Aleph detector at LEP, using approximately 3 million hadronic Z decays collected in the period 1991 1994. In the first of three methods, semileptonic decays of B 0 and B + mesons were partially reconstructed by identifying events containing a lepton with an associated D*- orbar D^0 meson. The second method used fully reconstructed B 0 and B + mesons. The third method, used to measure the B 0 lifetime, employed a partial reconstruction technique to identify B 0→ D*- π + X decays. The combined results are begin{gathered} tau _0 = 1.55 ± 0.06 ± 0.03 ps, \ tau _ + = 1.58 ± 0.09 ± 0.03 ps, \ tfrac{{tau _ + }}{{tau _0 }} = 1.03 ±…
Three-prong τ decays with charged kaons
1998
Final states with charged kaons in three-prong τ decays are studied by exploiting the particle identification from the dE/dx measurement. The results are based on a sample of about 1.6 × 105 detected τ pairs collected with the ALEPH detector between 1991 and 1995 around the Z peak. The following branching ratios have been measured: B(τ- → K−K+π−ντ) = (1.63 ± 0.21 ± 0.17) × 10−3, B(τ− → K−π+π−ντ) = (2.14 ± 0.37 ± 0.29) × 10−3, B(τ− → K−K+π−π0ντ) = (0.75 ± 0.29 ± 0.15) × 10−3, and B(τ− → K−π+π−π0ντ) = (0.61 ± 0.39 ± 0.18) × 10−3. The first two measurements are more precise than the current world averages, while the last two channels are investigated for the first time. The 95% C.L. upper limi…
SU-E-T-343: Valencia Applicator Commissioning Using a Micro-Chamber Array
2014
Purpose: In the commissioning and QA of surface isotope-based applicators, source-indexer distance (SID) has a great influence in the flatness, symmetry and output. To these purposes, methods described in the literature are the use of a special insert at the entrance of dwell chamber or radiochromic films. Here we present the experience with a micro-chamber array to perform the commissioning and QA of Valencia applicators. Methods: Valencia applicators have been used, the classic and the new extra-shielded version. A micro-chamber array has been employed, 1000 SRS (PTW), with 977 liquid filled, 2.3×2.3×0.5 mm3 sized ion chambers covering 11×11 cm2, which spacing is 2.5 mm in the central 5.5…
Calibration of the NEXT-White detector using 83m Kr decays
2018
The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterr'aneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using 83mKr decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for …
Neutrinoless double beta decay with 82 SeF 6 and direct ion imaging
2018
We present a new neutrinoless double beta decay concept: the high pressure selenium hexafluoride gas time projection chamber. Combining techniques pioneered in high pressure xenon gas such as topological discrimination, with the high Q-value afforded by double beta decay isotope $^{82}$Se, a promising new detection technique is outlined. Lack of free electrons in SeF$_6$ mandates the use of an ion TPC. The microphysics of ion production and drift, which have many nuances, are explored. Background estimates are produced suggesting such a detector may achieve background indices of better than 1 count per ton per year in the region of interest at the 100~kg scale, and still better at the ton-s…
The RICH counter in the CERN hyperon beam experiment
1992
Abstract The hyperon beam experiment WA89 at the CERN-SPS uses a ring imaging Cherenkov counter (RICH) for identification of secondaries from ∑ − N reactions. Cherenkov photons are generated in a 5 m long radiator volume filled with nitrogen at atmospheric pressure and detected in drift chambers. The drift chambers cover an active surface of 1.6 × 0.75 m 2 , with a maximum drift path of 41 cm. Photoelectrons are counted on 1280 wires with a pitch of 2.54 mm, equipped with multihit TDCs. The counting gas is ethane saturated with TMAE at 30°C. The counter was operated in two beam periods in 1990 and 1991. The spatial resolution of the chambers is better than 2 mm and under normal running cond…
High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach
2010
Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the respon…