Search results for "CHAMBER"
showing 10 items of 359 documents
Przywracanie pamięci... Rzecz o pasjach zbieraczych Konrada Mientusa
2019
The attention of the writer was attracted by the person of Konrad Mientus, who impressed with his passion of collecting all souvenirs, „props”, which passion became concrete in the form of an extremely valued and constantly visited regional chamber. A passion that was vivid from childhood was emphasized, and many examples of the Silesian regional chamber were referred to. Museum exhibits show the Opole region as a „smali homeland” of Poles and Germans - with all the complexity of the fate of its community, as well as the specificity of the Silesian culture, visible especially in tradition, dia- lect, customs and folk customs.
Correction factors for ionization chamber measurements with the ‘Valencia’ and ‘large field Valencia’ brachytherapy applicators
2018
Treatment of small skin lesions using HDR brachytherapy applicators is a widely used technique. The shielded applicators currently available in clinical practice are based on a tungsten-alloy cup that collimates the source-emitted radiation into a small region, hence protecting nearby tissues. The goal of this manuscript is to evaluate the correction factors required for dose measurements with a plane-parallel ionization chamber typically used in clinical brachytherapy for the 'Valencia' and 'large field Valencia' shielded applicators. Monte Carlo simulations have been performed using the PENELOPE-2014 system to determine the absorbed dose deposited in a water phantom and in the chamber act…
In vitro contamination of hair by marijuana smoke.
2004
Abstract Background: The deposition of cannabinoids on/into hair from environmental smoke can be considered as a potential source of drug findings in hair. We studied external uptake of cannabinoids from marijuana smoke, investigating possible influencing factors on drug uptake and the efficiency of decontamination procedures. Methods: Strands of a natural hair sample were moistened with water, greased with sebum or sebum/sweat, or bleached or permed. Treated and untreated samples were exposed to marijuana smoke for 60 min. Aliquots of each hair strand were either kept unwashed or were washed with methanol, dichloromethane, or 5 g/L dodecyl sulfate in water. Cannabinoid concentrations in un…
Digital Hydraulic Technology for Linear Actuation:A State of the Art Review
2020
This paper analyses the current state of the art in linear actuation with digital hydraulics. Based on the differences in their aims the paper partitions the area into four actuation concepts – parallel valve solutions, single switching valve solutions, multi-chamber cylinders, and multi-pressure cylinders. The concepts are evaluated based on accuracy and smoothness of motion, switching load, reliability, efficiency and the number of components required.
Posting for Consensus, Sharing Consensus. The Case of Migrants on Facebook, Ideological Views and Echo Chambers
2018
This study analyses posts and comments on a popular social network (Facebook) in order to investigate how web-users take advantage of participative platforms to post ideologically-driven comments, and how the exchanges create echo chambers. In particular, the study addresses populism expressed in online debates concerning migrants and used as a pretext to show group identities and ideologies. Facebook is thus taken as an example and considered a participatory platform (Boyd 2014) of political (populist) activism and the milieu for consensus-finding. The dialogic structure of comments is studied within Conversation Analysis adapted to online written texts (Antaki et al. 2005; Giles et al. 20…
Microphones’ Directivity for the Localization of Sound Sources
2011
In a recent paper [P. Rizzo, G. Bordoni, A. Marzani, and J. Vipperman, "Localization of Sound Sources by Means of Unidirectional Microphones, Meas. Sci. Tech., 20, 055202 (12pp), 2009] the proof-of-concept of an approach for the localization of acoustic sources was presented. The method relies on the use of unidirectional microphones and amplitude-based signals' features to extract information about the direction of the incoming sound. By intersecting the directions identified by a pair of microphones, the position of the emitting source can be identified. In this paper we expand the work presented previously by assessing the effectiveness of the approach for the localization of an acoustic…
Yttria-stabilized zirconia in-flight particle characteristics under vacuum plasma spray conditions
2009
This paper deals with the diagnostic yttria-stabilized zirconia (YSZ) in-flight particles in Vacuum Plasma Spray (VPS) process using an optical measurement device. Particle velocity, temperature and diameter were correlated to spray distance under a fixed chamber pressure of about 14 kPa. Experiments were carried out with a two-color pyrometer. Results show that correlations can be satisfactory described with linear relationships. Particle velocity and temperature decrease when increasing spray distance whereas particle diameter exhibits a linear increase with the spray distance.
Implementation of a global P-recovery system in urban wastewater treatment plants
2019
[EN] Current wastewater treatment plants (WWTPs) paradigm is moving towards the so-called water resource recovery facilities in which sewage is considered a source of valuable resources. In particular, urban WWTPs are crucial systems to enhance phosphorus (P) recycling. This paper evaluates the implementation of a P-recovery system in Calahorra WWTP combining the operation of a new sludge line configuration coupled to a struvite crystallisation reactor at demonstration-scale. This new configuration consisted in the elutriation in the gravity thickener of the mixed sludge contained in the mixing chamber in order to reduce the phosphate load to the anaerobic digestion. The results indicated t…
Commissioning of the ATLAS Muon Spectrometer with cosmic rays
2010
The ATLAS detector at the Large Hadron Collider has collected several hundred million cosmic ray events during 2008 and 2009. These data were used to commission the Muon Spectrometer and to study the performance of the trigger and tracking chambers, their alignment, the detector control system, the data acquisition and the analysis programs. We present the performance in the relevant parameters that determine the quality of the muon measurement. We discuss the single element efficiency, resolution and noise rates, the calibration method of the detector response and of the alignment system, the track reconstruction efficiency and the momentum measurement. The results show that the detector i…
Improved tau polarisation measurement
1996
Using 22 pb−1 of data collected at LEP in 1992 on the peak of the Z resonance, the ALEPH collaboration has measured the polarisation of the tau leptons decaying into $$ev\bar v, \mu v\bar v$$ ,πν, ρν and a1 ν from their individual decay product distributions. The measurement of the tau polarisation as a function of the production polar angle yields the two parametersN τ andN e, where, in terms of the axial and vector couplingsg Al andg Vl,N l=2g Vl gAl/(g Vl 2 +g 2 ). This analysis follows to a large extent the methods devised for the 1990 and 1991 data but with improvements which bring a better understanding of the systematic uncertainties. Combining the 1992 measurements with our previous…