Search results for "CHAMBER"
showing 10 items of 359 documents
Agreement between 2 swept-source OCT biometers and a Scheimpflug partial coherence interferometer
2020
PURPOSE To evaluate the agreement between different parameters obtained with 2 swept-source optical coherence tomography (SS-OCT)-based biometers and 1 Scheimpflug camera with partial coherence interferometry (PCI). SETTING Single center, Oftalvist, Alicante, Spain. DESIGN Prospective case series. METHODS Biometry was performed in 49 eyes using 3 optical biometers: ANTERION SS-OCT, IOLMaster 700 SS-OCT, and Pentacam AXL PCI. Keratometry (K), J0 and J45 vectors, anterior chamber depth (ACD), central corneal thickness (CCT), white-to-white (WTW), lens thickness (LT), and axial length (AL) were measured with each device. Bland-Altman analysis was applied. RESULTS This study comprises 49 eyes o…
Determining postoperative anterior chamber depth
2003
Abstract Purpose: To compare measured and calculated postoperative anterior chamber depths (ACDs). Setting: Department of Ophthalmology and Institute of Medical Physics, University of Vienna, Vienna, Austria, and Department of Ophthalmology, University of Mainz, Mainz, Germany. Methods: The postoperative ACD was measured in 189 pseudophakic eyes using a laboratory prototype of partial coherence interferometry (PCI). In 6 intraocular lens (IOL) groups, the mean ACD was calculated by ray tracing based on the best-known A-constants of the SRK formulas. In addition, for each IOL type, each measured ACD was compared with a value calculated using the individual spherical equivalent of the postope…
Complications Through the Use of Viscoelastics
2000
Viscoelastic material retained behind the IOL may cause a capsular bag distension in the early postoperative period. These eyes accumulate a transparent substance in the closed chamber inside the capsular bag from the IOL blocking the capsular opening. The capsular bag distension was first discribed by Davison in 1990. Miyake et al. proposed a new classification of capsular block syndrome and supposed viscoelastic material to cause early-postoperative capsular block syndrome (Miyake et al., 1999). Capsular bag distension after optic capture of a sulcus-fixated IOL was described by Basti et al. (1999).
Osmolality of various viscoelastic substances: comparative study.
2000
Abstract Purpose To determine the osmolality of various viscoelastic substances. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, and Institute for Medical Device Testing, Memmingen, Germany. Methods The analysis was carried out according to the European Pharmacopoeia by means of a calibrated osmometer using the freezing-point depression method. Each syringe was analyzed as a duplicate analysis. Results Mean osmolalities (mOsmol/kg) of the sodium hyaluronate viscoelastic substances were Allervisc® 299; Allervisc® Plus 307; Amvisc® Plus 335; AMO Vitrax® 284; Biolon® 279; Dispasan® 311; Dispasan® Plus 314; Healon® 295; Healon GV® 312; Healon®5 322; HYA-Ophtal® 376; M…
Optical analysis to predict outcomes after implantation of a double intraocular lens magnification device.
2007
Purpose To analyze the effect of different optical parameters of the eye on the outcomes of implantation of a double intraocular lens (IOL) magnification device in patients with low vision. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The eye's refraction and magnification before and after surgery were evaluated using a theoretical eye model based on paraxial optics approximation. Four parameters on which refraction and magnification are dependent were evaluated: anterior chamber depth (ACD), axial length (AL), mean keratometry (Km), and the distance between the 2 implanted IOLs. The 4 variables were analyzed separately in the first stage. Next, different combi…
Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes
2006
Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…
Lens implant selection with absence of capsular support.
2001
If contact lens or spectacle correction is not viable, little debate exists that the secondary placement of an intra-ocular lens (IOL) is the method of choice in the absence of capsular support. The choice of IOL mainly depends on the preoperative status of the eye (eg, aphakia in children) and the selected location for the implant. Theoretically, there are several IOL implantation approaches in cases without capsular support: an angle-supported anterior chamber (AC) IOL, an iris-fixated ACIOL, an iris-sutured or iris-fixated posterior chamber (PC) IOL and a transsclerally sutured PCIOL. No consensus exists, however, on the indications as well as on the relative safety and efficacy of these…
Preliminary in vivo positional analysis of a posterior chamber phakic intraocular lens by optical coherence tomography and its correlation with clini…
2012
Purpose: To analyze by spectral-domain optical coherence tomography the anatomical relationship of a specific type of posterior chamber phakic intraocular lens (pIOL) implanted in cases of high to moderate myopia with the adjacent intraocular structures and to correlate it with clinical outcomes. Methods: Prospective observational case series including 18 eyes with high to moderate myopia (spherical equivalent between −5.88 and −15.75 D) of 9 patients (age range, 29–49 years) undergoing bilateral Phakic Refractive Lens (PRL, Zeiss) implantation. Postoperative visual acuity, refraction, contrast sensitivity (CS), and ocular higher order aberrations (HOA) were evaluated. Furthermore, the in v…
The "sandwich technique" for iris-fixated phakic intraocular lens implantation.
2006
ABSTRACT PURPOSE: To describe a new technique of implantation of the Artisan/Verisyse phakic intraocular lens (PIOL). METHODS: After PIOL insertion into the anterior chamber, a bolus of a high viscosity ophthalmic viseosurgical device (OVD) is placed over the optic, separating it widely from the endothelium. RESULTS: The technique decreases the chance of endothelial damage during enclavation. CONCLUSIONS: A bolus of a high viscosity OVD placed on the anterior surface of the Artisan/Verisyse PIOL may make enclavation safer. [J Refract Surg. 2006;22:96-98.]
Anterior chamber depth measurement in teenagers. Comparison of two techniques
2013
Purpose: The aim of this study is to determine the anterior chamber depth (ACD) in teenagers using two different devices: partial coherence interferometry IOLMaster (Carl Zeiss Meditec) and anterior segment optical coherence tomography (Visante TM OCT, Carl Zeiss Meditec) and to evaluate the degree of agreement between ACD measurements carried out by both instruments. Methods: In this prospective study 68 eyes of 34 emmetropic Caucasic patients (18 girls and 16 boys) were analysed. ACD was measured from the anterior corneal surface to anterior surface of the crystalline lens. For each age the ACD size was calculated and the difference between IOLMaster and Visante-OCT measurements was analy…