Search results for "CLEAR"
showing 10 items of 27042 documents
EPR dosimetry intercomparison using smart phone touch screen glass
2014
International audience; This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogene…
Cytogenetics of the land snails Cantareus aspersus and C. mazzullii (Mollusca: Gastropoda: Pulmonata).
2004
A cytogenetic study was carried out on the chromosomes and nuclear DNA contents of the land snails Cantareus aspersus and C. mazzullii (Gastropoda: Pulmonata). Chromosomes were studied using Giemsa staining, banding methods and fluorescent in situ hybridization (FISH) with three repetitive DNA probes [18S rDNA, (GATA)n and (TTAGGG)n]. Results were very similar in the two species both showing (1) 54 bi-armed chromosomes [submetacentrics (SM) C metacentrics (M) C subtelocentrics (ST)]; (2) 10 terminal NORs after sequential application of rDNA FISH and silver staining; (3) uniform DNA fluorescence with CMA3 and DAPI staining and (4) genomic composition considerably enriched both in highly- and…
Up-to-date imaging review of paediatric soft tissue vascular masses, focusing on sonography
2019
The purpose of this article is to provide an up-to-date overview on imaging of paediatric vascular soft tissue masses, including both neoplastic and non-neoplastic lesions. We describe the-often challenging-imaging diagnosis-mainly performed by ultrasound (and secondarily by MRI) and differential diagnosis of vascular soft tissue lesions in children. We underline how important it is to determine whether a vascular anomaly has a regional vascular origin, or if there are other entities, ranging from benign to malignant lesions, which have flow-signal or blood degradation products. Even though clinical examination and patient's history are the first and indispensable steps in the initial diagn…
Primary intra and extradural solitary fibrous tumor/hemangiopericytoma of thoracic spine with paravertebral intrathoracic spread: Case report and rev…
2020
Abstract Solitary fibrous tumors/hemangiopericytomas (SFTs/HPCs), constitute 1% of all CNS tumors. Spinal SFTs/HPCs are extremely rare. To date, few retrospective studies and case reports of primary spinal SFTs/HPCs have been published in the literature. We report clinical and radiological presentation, surgical treatment, and post-operative outcome at three years follow-up of a rare case of primary spinal intra and extradural SFT/HPC of thoracic spine with dumbbell shaped paravertebral intrathoracic spread and multidirectional erosion of the bone. A 73-year-old female presented with progressive lower limbs weakness and hypoesthesia below the rib cage. MRI showed an irregular isointense T5-…
A new resonant Laser-SNMS system for environmental ultra-trace analysis: Installation and optimization
2017
Abstract Localization, analysis and mobility of radioactive contaminated particles is of major concern for assessment of contamination threads and nuclear forensics. For this purpose, a new resonant Laser-SNMS system was developed and set up at the Institute for Radioecology and Radiation Protection for spatially resolved ultra-trace analysis of low concentrated radionuclides directly on environmental samples. This paper describes the adaption and combination of a dedicated Ti:sapphire laser system with a commercial TOF-SIMS instrument for resonant Laser-SNMS. The project includes computer simulations for optimization of the TOF analyzer. Results on synthetic uranium and technetium samples …
Spiral-CT und 3 D-Rekonstruktion des Tracheobronchialbaumes zur Auswahl geeigneter Doppellumentuben vor Einzellungenbeatmung
1997
Purpose To assess the potential of 3-D spiral CT in the selection of adequate double-lumen tubes (DLT) for one-lung-ventilation. Materials and methods 3-D spiral CT of eight different DLTs was performed with standardized acquisition parameters: section thickness 4 mm, table speed 6 mm/s, increment 3 mm and standardised thresholds, window settings and magnification zoom. The accuracy was confirmed by measuring 3-D objects on screen and original DLTs by vernier caliper. 3-D spiral CT was performed in 20 patients preoperatively with slice thickness 4-8 mm, pitch 1-1.5, increment 4-8 mm. To select the adequate DLT size the 3-D reconstructions of the patient's tracheobronchial tree and of the DL…
A low threshold to ECG-gated repeat CTA reduces the risk of false-positive diagnosis of type A dissection in interhospital referrals: a case series s…
2018
Angela Kornberger,1 Iris Burck,2 Hazem El Beyrouti,1 Nancy Halloum,1 Andres Beiras-Fernandez,1 Christian-Friedrich Vahl1 1Department of Cardiothoracic and Vascular Surgery, University Hospital of Johannes Gutenberg University, Mainz, Germany; 2Department of Diagnostic and Interventional Radiology, University Hospital of Johann Wolfgang Goethe University, Frankfurt am Main, Germany Background: False-positive diagnosis of acute Stanford type A aortic dissection (AAD) on computed tomography angiography (CTA) is still an issue and may lead to substantial consequences. Given that electrocardiography (ECG)-gated CTA provides greater diagnostic safety, it may be assumed that interhospital referral…
Stereotactic body radiation therapy for liver oligometastases: predictive factors of local response by 18F-FDG-PET/CT
2018
Objective:To investigate metabolic parameters as predictive of local response after stereotactic body radiation therapy (SBRT) for liver-oligometastases.Methods:Inclusion criteria of the present re...
Infrared thermal imaging in the diagnosis of musculoskeletal injuries: a systematic review and meta-analysis.
2014
OBJECTIVE. Musculoskeletal injuries occur frequently. Diagnostic tests using ionizing radiation can lead to problems for patients, and infrared thermal imaging could be useful when diagnosing these injuries. CONCLUSION. A systematic review was performed to determine the diagnostic accuracy of infrared thermal imaging in patients with musculoskeletal injuries. A meta-analysis of three studies evaluating stress fractures was performed and found a lack of support for the usefulness of infrared thermal imaging in musculoskeletal injuries diagnosis.