Search results for "COMPOSITE"
showing 10 items of 4584 documents
Composite femoro-tibial bypass as alternative solution in complicated revascolarization: Case report
2021
Introduction Peripheral Arterial Disease (PAD) in diabetic patients is a significant cause of Morbility. Long arterial occlusion in patient previously treated can require unusual and complex solution. Herein we report a case of complicated bypass in diabetic patient with history of bypass for bilateral popliteal aneurysm. Presentation of case A 51-year-old male, smoker, with hypertension and diabetes mellitus was referred to our hospital for rest pain in left limb and peripheral cyanosis. Ultrasound doppler (US) showed an occlusion after common femoral artery with patency of Anterior-tibial artery (ATA) two centimeters after the origin. The unavailability of adequate autologous conduit nece…
Facial transplantation: A concise update
2012
Objectives: Update on clinical results obtained by the first worldwide facial transplantation teams as well as review of the literature concerning the main surgical, immunological, ethical, and follow-up aspects described on facial transplanted patients. Study design: MEDLINE search of articles published on “face transplantation” until March 2012. Results: Eighteen clinical cases were studied. The mean patient age was 37.5 years, with a higher prevalence of men. Main surgical indication was gunshot injuries (6 patients). All patients had previously undergone multiple conventional surgical reconstructive procedures which had failed. Altogether 8 transplant teams belonging to 4 countries part…
Spring constants of capsular tension rings.
2004
Purpose To determine the spring constants of several types of capsular tension rings (CTRs). Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Fourteen models of CTRs provided by 9 companies were tested; all were 11.0 mm in diameter. The CTRs were positioned in a special retainer of a material-testing machine and compressed at a constant speed of 10.0 mm per minute. The distance and force values were recorded, and each CTR model was tested 3 times using a new specimen each time. The resulting measurements were used to calculate a mean spring constant for each CTR model. Results All tested CTRs showed linear proportionality between force and compress…
Healon5 viscoadaptive formulation: Comparison to Healon and Healon GV
2001
Abstract Purpose To compare the rheological characteristics of a viscoadaptive viscoelastic formulation with those of 2 standard ophthalmic viscosurgical devices (OVDs). Setting Department of Ophthalmology, Johannes Gutenberg-University, and Max Planck-Institute for Polymer Research, Mainz, Germany. Methods An independent comparative study of 3 OVDs of sodium hyaluronate (Healon®, Healon GV®, and Healon®5) was performed using the Advanced Rheometric Expansion System to analyze rheologic behavior (eg, dynamic frequency dependence of the complex viscosity) as well as rheological parameters (eg, viscosity at zero shear rate, pseudoplasticity, relaxation time, elastic and viscous modulus). Resu…
Bond strength of cemented fiber posts to teeth with simulated internal root resorption
2020
Made available in DSpace on 2021-06-25T10:58:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-03-01 Background: Teeth with internal root resorption (IRR) have guarded prognosis, considering that IRR defect could influence on the post bond strength. The aim of this study was to evaluate the bond strength and the bond interface between different glass fiber-reinforced posts (FRP) after cementation in teeth with simulated internal root resorption (IRR). Material and Methods: Forty-five (45) human premolar roots with simulated IRR were embedded in acrylic resin blocks and cross-sectioned into two segments, enabling them to be re-approximated by screws. Intracanal medication was inserte…
The Effect of surface topographical changes of two different surface treatments rotary instrument
2018
Background One of the major innovations in endodontics has been the introduction of nickel-titanium (NiTi) alloy. This study evaluated the surface topographical changes of two different surface treatments rotary instrument after instrumentation and sterilization. Material and Methods 240 Extracted teeth were included in this study. 90 new AlphaKite and Revo-S NiTi rotary instruments were selected and divided into two groups (Group A 45 AlphaKite and group B 45 Revo-S). Each group were divided into three subgroups: (A1, B1) n=5 files were used as a control, (A2,B2) n=20 files were used to prepare three root canals using endodontic rotary motor then sterilized by autoclave for one cycle under…
Advances in surfaces and osseointegration in implantology. Biomimetic surfaces
2015
The present work is a revision of the processes occurring in osseointegration of titanium dental implants according to different types of surfaces -namely, polished surfaces, rough surfaces obtained from subtraction methods, as well as the new hydroxyapatite biomimetic surfaces obtained from thermochemical processes. Hydroxyapatite’s high plasma-projection temperatures have proven to prevent the formation of crystalline apatite on the titanium dental implant, but lead to the formation of amorphous calcium phosphate (i.e., with no crystal structure) instead. This layer produce some osseointegration yet the calcium phosphate layer will eventually dissolve and leave a gap between the bone and …
Teaching the placement of posterior resin-based composite restorations in Spanish dental schools
2012
Objectives: In an area of esthetic dentistry such as posterior composites, in which new materials and techniques are being devolved continuously, it is important to confirm that dental students have a clear understanding of the basic principles of clinical application of this knowledge. Considering that the preparation of dental graduates in Spain may be of interest to competent dental authorities and employers with whom they can work worldwide, this study investigated the teaching of posterior composite restorations in Spanish dental schools. Study design: In late 2009/ early 2010, a questionnaire seeking information on the teaching of posterior composites was emailed to the professor resp…
Perfluoroalkylated amphiphilic MUC1 glycopeptide antigens as tools for cancer immunotherapy.
2010
The synthesis of perfluoroalkylated glycopeptide antigens and their specific binding to anti-MUC1 mouse antibodies is reported.