Search results for "COMPOSITION"

showing 10 items of 2675 documents

A study on the essential oil of Ferulago campestris : How much does extraction method influence the oil composition?

2011

The essential oil of different parts of Ferulago campestris (Bess.) collected in Sicily has been extracted by microwave-assisted hydrodistillation (MAHD) and by classic hydrodistillation (HD). A comparative qualitative-quantitative study on the composition of the oils was carried out. A total of 100 compounds were identified in the oils obtained by MAHD, whereas 88 compounds characterized the HD oils. The most prominent components were, in all different parts of F. campestris and in both extraction methods, 2,4,5-trimethylbenzaldehyde and 2,4,6-trimethylbenzaldehyde isomers; the latter was not previously found. The attempt to evaluate where the oil components are located in all parts of the…

ChromatographyChemistrylawFiltration and SeparationComposition (visual arts)Extraction methodsFerulago campestrisEssential oilAnalytical Chemistrylaw.inventionJournal of Separation Science
researchProduct

Free fatty acids and other volatile compounds for the characterisation of “Vastedda della valle del Belìce” cheese Acidos grasos libres y otros const…

2010

The analysis of the volatile constituents of “Vastedda della valle del Belice”, a typical Sicilian pasta filata cheese, was performed using solid phase microextraction and high-resolution gas chromatography/mass spectrometry. The research aimed to verify if the volatile fraction, determinant for cheese flavor, differs among producers and/or production seasons. The samples were provided by four producers from the area of the Protected Designation of Origin (PDO) production, during two different seasons of production. A total of 42 volatile components were identified: the main components were found to be butanoic, hexanoic, octanoic, and decanoic acid. Free fatty acids were quantified using t…

ChromatographyGeneral Chemical EngineeringCheese FlavorGeneral ChemistryDecanoic acidSolid-phase microextractionIndustrial and Manufacturing Engineeringchemistry.chemical_compoundchemistryStandard additionFood scienceGas chromatographyGas chromatography–mass spectrometryChemical compositionFood ScienceCyTA - Journal of Food
researchProduct

Evolution of phenolic compounds virgin olive oil during storage

1997

Phenolic compounds are of fundamental importance to the shelf life of virgin olive oils because of their antioxidative properties. In this paper, the evolution of simple and complex olive oil phenols during 18 mon of storage is studied by high-performance liquid chromatography (HPLC) analysis. The olive oils under examination were from various olive cultivars, harvested in two sectors in the same region at different stages of ripeness. The findings indicate that it is not the variety but rather the ripeness of the olives and the soil and climate that influence the phenol composition of virgin olive oil. In addition, a positive correlation was found between the age of the oils and the tyroso…

ChromatographyGeneral Chemical EngineeringOrganic Chemistryfood and beveragesRipenessShelf lifeTyrosolchemistry.chemical_compoundchemistryOleuropeinCaffeic acidHydroxytyrosolComposition (visual arts)PhenolsFood science
researchProduct

High-performance liquid chromatographic determination of Maillard compounds in store-brand and name-brand ultra-high-temperature-treated cows' milk.

2000

Furosine and furfural products of the Maillard reaction are used as specific indicators of the effect of heating treatments on milk quality. Their contents were measured in representative samples of store- and name-brand ultra-high-temperature-treated milks using RP-HPLC with UV detection. Furosine contents ranged from 40.32 to 50.67 and from 65.48 to 310.58 mg/100 g protein in name- and store-brand milks, respectively. Of the furfurals, only hydroxymethylfurfural was detected. The free hydroxymethylfurfural contents of store-brand milks ranged from 0.22 to 1.70 mg/100 g protein. Total hydroxymethylfurfural contents ranged from 0.29 to 0.41 and from 0.72 to 2.21 mg/100 g protein, for name- …

ChromatographyHot TemperatureOrganic ChemistryFood composition dataGeneral MedicineReversed-phase chromatographyFurfuralBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryMaillard Reactionchemistry.chemical_compoundMaillard reactionsymbols.namesakeMilkchemistrysymbolsAnimalsCattleSpectrophotometry UltravioletUv detectionQuantitative analysis (chemistry)HydroxymethylfurfuralChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

Robust interpretive optimisation in high-performance liquid chromatography considering uncertainties in peak position.

2005

In the context of interpretive chromatographic optimisation, robustness is usually calculated by introducing deliberated shifts in the nominal optimal conditions and evaluating their effects on the monitored objective function, mimicking thus the experimental procedures used in method validation. However, such strategy ignores a major source of error: the uncertainties associated to the modelling step, that may give rise to deceiving results when conditions that were expected to yield baseline separation are reproduced in the chromatograph. Two approaches, based on the peak purity concept, are here proposed to evaluate the robustness of the objective function under the perspective of measur…

ChromatographyObservational errorComputer simulationChemistryComputationOrganic ChemistryGeneral MedicineModels TheoreticalBiochemistryAnalytical ChemistryRobustness (computer science)Phase compositionAmino AcidsMonte Carlo MethodChromatography High Pressure LiquidSpectral purityJournal of chromatography. A
researchProduct

Infrared biospectroscopy for a fast qualitative evaluation of sample preparation in metabolomics.

2014

Liquid chromatography-mass spectrometry (LC-MS) has been increasingly used in biomedicine to study the dynamic metabolomic responses of biological systems under different physiological or pathological conditions. To obtain an integrated snapshot of the system, metabolomic methods in biomedicine typically analyze biofluids (e.g. plasma) that require clean-up before being injected into LC-MS systems. However, high resolution LC-MS is costly in terms of resources required for sample and data analysis and care must be taken to prevent chemical (e.g. ion suppression) or statistical artifacts. Because of that, the effect of sample preparation on the metabolomic profile during metabolomic method d…

ChromatographyPlasma samplesChemistryPlasma compositionIon suppression in liquid chromatography–mass spectrometryBlood ProteinsMass spectrometryMethod developmentMass SpectrometryAnalytical ChemistryMice Inbred C57BLExploratory data analysisMetabolomicsSpectroscopy Fourier Transform InfraredAnimalsMetabolomicsSample preparationFemaleChromatography LiquidTalanta
researchProduct

Liquid/Gas and Liquid/Liquid Phase Behavior of n-Butane/1,4-Polybutadiene versus n-Butane/1,2-Polybutadiene

2005

Solutions of 1,4-polybutadiene (1,4-PB, 98% cis) and of 1,2-polybutadiene (1,2-PB) in n-butane (n-C 4 ) were studied with respect to their vapor pressure and to their demixing into two liquid phases under isochoric conditions within the temperature range from 25 to 75 °C. 1,2-PB mixes homogeneously with n-C 4 at any ratio, in contrast to 1,4-PB, which exhibits a miscibility gap extending from practically pure solvent to approximately 40 wt % polymer. Corresponding to these solubility differences, the vapor pressures for the system n-C 4 /1,4-PB are considerably higher than for n-C 4 /1,2-PB at the same concentration and temperature. The experimental results are modeled accurately and consis…

ChromatographyPolymers and PlasticsIsochoric processSpinodal decompositionVapor pressureOrganic ChemistryThermodynamicsButaneMiscibilityInorganic Chemistrychemistry.chemical_compoundPolybutadienechemistryPhase (matter)Materials ChemistrySolubilityMacromolecules
researchProduct

Volatile compounds extracted from polypropylene pellets by hot water: influence of the level of the peroxide agents

1992

To improve the quality level of plastic packaging materials, we determined the influence of chemical degradation of polypropylene (PP) upon the amount of volatile components extracted by hot water from PP pellets. Two formulations were analyzed and compared: PP CR (degraded) and PP (not degraded). After Likens-Nickerson's extraction of the pellets and concentration of the extract, an HPLC fractionation was made to collect three fractions of different poiarities: a pentane (A), a dichloromethane (B), and an ether (C) fraction. Fractions (B) and (C) were olfactively evaluated by GC sniffing to be most interesting. Their analysis by GC/MS coupling allowed the identification of different compon…

ChromatographyPolymers and PlasticsNonanal[SDV]Life Sciences [q-bio]010401 analytical chemistryPellets02 engineering and technologyGeneral ChemistryDecanal021001 nanoscience & nanotechnology01 natural sciencesPeroxide0104 chemical sciencesSurfaces Coatings and FilmsPentane[SDV] Life Sciences [q-bio]chemistry.chemical_compoundchemistryMaterials ChemistryPhenols0210 nano-technologyChemical decompositionComputingMilieux_MISCELLANEOUSDichloromethane
researchProduct

Determination of water-soluble vitamins in energy and sport drinks by micellar electrokinetic capillary chromatography

2016

Abstract A method for the determination of water-soluble vitamins in several energy and sport drinks by micellar electrokinetic chromatography (MEKC) has been developed in this work. The separation of vitamins was studied in terms of background electrolyte composition (borate content, pH, surfactant type and content) and in other MEKC parameters. A study of the possible compounds found in the vitamin-enriched drinks that could interfere in vitamin determination was also performed, and a modified procedure with enhanced resolution was developed. The proposed method was successfully applied to the analysis of water-soluble vitamins in a variety of energy and sport drinks and also in fruit nec…

ChromatographyResolution (mass spectrometry)Chemistry010401 analytical chemistry04 agricultural and veterinary sciences040401 food science01 natural sciencesMicellar electrokinetic chromatography0104 chemical sciences0404 agricultural biotechnologyPulmonary surfactantReagentWater-Soluble VitaminSample preparationElectrolyte compositionSoft drinkFood ScienceBiotechnologyFood Control
researchProduct

On the Measurement of Dead Time in Micellar Liquid Chromatography

1996

Abstract Modelling of the retention of solutes in micellar liquid chromatography allows the optimization of the resolution of a mixture of solutes and the determination of physico-chemical retention parameters. Both tasks imply the calculation of capacity factors, which are severely affected by the value of dead time. However, the determination of the dead time is not easy when a micellar mobile phase is used owing to the wide and variable perturbations that appear at the heads of the chromatograms. Four different criteria of determination of a reference time in the chromatograms are proposed and compared. The criteria are applied to mobile phases containing a varying concentration of surfa…

ChromatographyResolution (mass spectrometry)ChemistryClinical BiochemistryAnalytical chemistryPharmaceutical ScienceDead timeBiochemistryCapacity factorAnalytical ChemistryPulmonary surfactantMicellar liquid chromatographyPhase compositionPhase (matter)Retention timeJournal of Liquid Chromatography & Related Technologies
researchProduct