Vergleich radiologischer Verfahren zur präoperativen Beurteilung der Verankerungsfestigkeit von Wirbelsäulenimplantaten

1997

PURPOSE To compare three techniques with regards to their ability to estimate pull out strength of spinal fusion hardware. MATERIAL AND METHODS VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pull out force measurement. Bone quality was assessed by Dual X-ray Absorptiometry (DXA). Quantitative Computed Tomography (QCT) and T2*-relaxation time. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS Highest correlation was found for cancellous bone density measured by QCT (r = 0.72; p < 0.001). Immediately followed by DXA (r = 0.70; p < 0.001), which involves all bone components. Inverted T2*-relax…

musculoskeletal diseasesMaterials sciencemedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentmedicine.anatomical_structureNuclear magnetic resonanceSpinal fusionBone qualitymedicineRadiology Nuclear Medicine and imagingCortical boneDual x-ray absorptiometryQuantitative computed tomographyCadaveric spasmNuclear medicinebusinessCancellous boneFixation (histology)RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Influence of Drilling Technique on the Radiographic, Thermographic, and Geomorphometric Effects of Dental Implant Drills and Osteotomy Site Preparati…

2020

The aim of this comparative study is to analyze the influence of drilling technique on the radiographic, thermographic, and geomorphometric effects of dental implant drills and osteotomy site preparations. One hundred and twenty osteotomy site preparations were performed on sixty epoxy resin samples using three unused dental implant drill systems and four drilling techniques performed with a random distribution into the following study groups: Group A: drilling technique performed at 800 rpm with irrigation (n = 30)

musculoskeletal diseasesOsteotomy siteCone beam computed tomographymedicine.medical_treatmentRadiographyeducationlcsh:MedicineOsteotomyArticle03 medical and health sciences0302 clinical medicineotorhinolaryngologic diseasesmedicineheat generationdrill coolingDental implantOrthodonticsDrillbusiness.industrylcsh:RDrilling030206 dentistryGeneral Medicinedental implants drillsequipment and supplieslow drilling speed030220 oncology & carcinogenesisHeat generationbusinessosteotomyJournal of Clinical Medicine
researchProduct

Uso de la tomografía computarizada en el diagnóstico de la anquilosis de la articulación temporomandibular: Presentación de dos casos clínicos

2006

La anquilosis de la articulación temporomandibular es definida como la abolición o limitación de los movimientos de dicha articulación. Radiográficamente la anquilosis demuestra aspectos bien característicos que facilitan el diagnóstico, sin embargo, su análisis en las técnicas radiográficas convencionales, en la mayoría de las veces, no se presenta de forma clara. Con la evolución de las técnicas radiográficas, la tomografía computarizada pasó a ser un examen de gran importancia en el diagnóstico de las anquilosis temporomandibulares. En vista de ello, el presente trabajo se propone mostrar y describir imágenes tomográficas de la anquilosis de esta articulación, presentando dos casos clíni…

musculoskeletal diseasesarticulación temporomandibularAnquilosistomografía computarizada por rayos XAnkylosisUNESCO::CIENCIAS MÉDICAStemporomandibular jointcomputed tomography:CIENCIAS MÉDICAS [UNESCO]
researchProduct

Bestimmung der Knochenqualität vor Wirbelsäuleninstrumentation - Stellenwert verschiedener in vivo-Methoden

2008

OBJECTIVE: The present investigation should elucidate which assessment technique for bone quality is most appropriate to estimate preoperatively fixation strength of instrumental spine fusions. METHODS: VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pullout force assessment. Bone quality was assessed by Dual Energy X-ray Absorptiometry (DEXA), Quantitative Computed Tomography (QCT), MRT and histomorphometry. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS: Highest correlation was found for cancellous bone density (QCT) (r = 0.72; p < 0.001) and DEXA (r = 0.70; p < 0.001). MRT, cortical bo…

musculoskeletal diseasesmedicine.medical_specialtymedicine.diagnostic_testBone densitybusiness.industrymedicine.medical_treatmentmusculoskeletal systemSurgerymedicine.anatomical_structureSpinal fusionmedicineOrthopedics and Sports MedicineSurgeryCortical boneQuantitative computed tomographyNuclear medicinebusinessCadaveric spasmCancellous boneDual-energy X-ray absorptiometryFixation (histology)Zeitschrift für Orthopädie und ihre Grenzgebiete
researchProduct

Transcranial Magnetic Stimulation and Neuroimaging Coregistration

2013

The development of neuroimaging techniques is one of the most impressive advancements in neuroscience. The main reason for the widespread use of these instruments lies in their capacity to provide an accurate description of neural activity during a cognitive process or during rest. This important advancement is related to the possibility to selectively detect changes of neuronal activity in space and time by means of different biological markers. Specifically, functional magnetic resonance imaging (fMRI), positron emission tomography (PET), single-photon emission computed tomography (SPECT), and nearinfrared spectroscopy (NIRS) use metabolic markers of ongoing neuronal activity to provide a…

neuroimagingmedicine.diagnostic_testComputer sciencemedicine.medical_treatmentCognitionElectroencephalographyTranscranial magnetic stimulationNeuroimagingPositron emission tomographymedicinePremovement neuronal activityFunctional magnetic resonance imagingNeuroscienceEmission computed tomographynon presenti
researchProduct

Diseño y puesta a punto de un método cefalométrico en 3D para el estudio de la población ortodóncica

2011

Introducción: La introducción de la tomografía computarizada de haz cónico (CBCT) y su aplicación clínica a la imagen craneofacial tridimensional (3D) supone una herramienta diagnóstica esencial para el clínico. Objetivos: 1-Evaluar la reproducibilidad en la localización de puntos cefalométricos pertenecientes a tejidos duros del cráneo sobre imágenes escaneadas con un equipo CBCT 2-Comprobar si los valores de diferentes mediciones de las reconstrucciones 3D del CBCT se pueden comparar a las mediciones realizadas sobre imágenes 2D de la telerradiografía lateral de cráneo y comparar también si existen diferencias entre dos tipos diferentes de software de CBCT. 3-Diseñar un método cefalométri…

ortodonciareliabilityCBCT; cefalometría 3D; ortodonciatomografía computarizada de haz cónico3D cephalometryCBCTFacultat de Medicina i Odontologia616.3plano de referencia:CIENCIAS MÉDICAS [UNESCO]cefalometría 3DCone Beam Computed TomographyreproducibilidadlandmarkUNESCO::CIENCIAS MÉDICASorthodonticsanálisis cefalométrico 3D
researchProduct

Comparison of 99mTc-Labeled Colloid SPECT/CT and Planar Lymphoscintigraphy in Sentinel Lymph Node Detection in Patients with Melanoma: A Meta-Analysis

2020

We compared the detection rate (DR) for sentinel lymph nodes (SLNS), the number of SLNs and the subjects with additional SLNs of single-photon emission computed tomography (SPECT/CT) and planar lymphoscintigraphy (PL) in patients with melanoma. Furthermore, we evaluated the impact of SPECT/CT on surgical plans. Articles containing head-to-head comparisons between SPECT/CT and PL were searched in Pubmed/MEDLINE and Scopus. The literature search was updated until December 31st, 2019. DR was calculated on a per-patient-based analysis; the studies were pooled by their odds ratios (ORs) with a random effects model to assess the significance of difference (p &lt; 0.05). The number of additional S…

planar lymphoscintigraphySentinel lymph nodelcsh:MedicineSingle-photon emission computed tomography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinesentinel lymph node99mTc-labeled colloidsmedicinemelanomamedicine.diagnostic_testbusiness.industryMelanomalcsh:RGeneral MedicineOdds ratiomedicine.diseaseConfidence intervalbody regionsmeta-analysis<sup>99m</sup>Tc-labeled colloids030220 oncology & carcinogenesisRelative riskMeta-analysis99mTc-labeled colloids; melanoma; meta-analysis; planar lymphoscintigraphy; sentinel lymph node; single photon emission/computed tomographysingle photon emission/computed tomographyNuclear medicinebusinessEmission computed tomographyJournal of Clinical Medicine
researchProduct

Intravenous Contrast Material for Cardiac Computed Tomography

2023

Purpose: The Italian Registry of Contrast Material use in Cardiac Computed Tomography (iRCM-CCT) is a multicenter, multivendor, observational study on the use of contrast media (CM) in patients undergoing cardiac computed tomography (CCT). The aim of iRCM-CCT is to assess image quality and safety profile of intravenous CM compounds. Materials and methods: iRCM-CCT enrolled 1842 consecutive patients undergoing CCT (≥50 per site) at 20 cluster sites with the indication of suspected coronary artery disease. Demographic characteristics, CCT, and CM protocols, clinical indications, safety markers, radiation dose reports, qualitative (ie, poor vascular enhancement) and quantitative (ie, HU attenu…

safetyPulmonary and Respiratory MedicineSettore MED/36 - Diagnostica per Immagini e Radioterapiacoronary arteriecomputed tomography angiography; contrast media; coronary arteries; image enhancement; safetyRadiology Nuclear Medicine and imagingcomputed tomography angiography; contrast media; coronary arteries; image enhancement; safety;image enhancementcontrast mediacomputed tomography angiographycoronary arteriesimage enhancement contrast media safetycomputed tomography angiographycoronary arteriesimage enhancementcontrast mediasafetyJournal of Thoracic Imaging
researchProduct

Relationship between volume of submandibular salivary stones in vivo determined with cone-beam computer tomography and in vitro with micro-computer t…

2021

Background Successful removal of salivary stones depends on exact pretreatment information of the location, the size and shape of the stones. This study aimed to compare the volume of submandibular sialoliths determined by preoperative Cone-Beam Computer Tomography (CBCT) scans with the volume of the removed stones on micro-Computer Tomography (micro-CT) scans. Material and Methods In this study, using twenty-one submandibular sialoliths, the pretreatment volumes in-vivo measured on CBCT were compared to the volumes of removed stones determined by micro-CT scans. The volume measured on micro-CT scans served as the gold standard. Pre-operative CBCT’s and in-vitro micro-CT’s were converted in…

stomatognathic systemdental implantsMedicineHumansSalivary stoneMicro ctGeneral DentistryUNESCO:CIENCIAS MÉDICASSalivary Gland CalculiOral Medicine and Pathologybusiness.industryComputersResearchchlorhexidineMicro tomographyCone-Beam Computed TomographySoftware packageOtorhinolaryngologySurgeryStone removalTomographybiofilmserythritolNuclear medicinebusinessperi-implantitisVolume (compression)Medicina Oral, Patologia Oral y Cirugia Bucal
researchProduct

Evaluation of alveolar cortical bone thickness and density for orthodontic mini-implant placement.

2013

Objective: Mini-implant stability is primarily related to bone quality and quantity. This study evaluated alveolar cortical bone thickness and density differences between interradicular sites at different levels from the alveolar crest, and assessed the differences between adolescents (12-18 years of age) and adults (19-50 years of age), males and females, upper and lower arch, anterior and posterior region of jaws and buccal and oral side. Study Design: In this retrospective study, 48 Computed Tomography scans, performed for oral surgery purposes were selected from dental records of 3,223 Caucasian orthodontic patients. The SimPlant software (Materialise, Leuven, Belgium) was used to measu…

temporary anchorage devicesDentistryComputed tomographyOdontologíaOrthodonticsAlveolar crestcortical bone thickness; computed tomography; cortical bone density; orthodontics; mini-implant; temporary anchorage devicesmedicinemini-implantStatistical analysisGeneral Dentistrymedicine.diagnostic_testbusiness.industryResearchMandiblecomputed tomography:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludmedicine.anatomical_structureMini implantscortical bone thicknessMaxillaUNESCO::CIENCIAS MÉDICAScortical bone densityCortical boneCrestbusinessJournal of clinical and experimental dentistry
researchProduct