Search results for "CONTRACTION"

showing 10 items of 1092 documents

Positive inotropic response to 5-HT in human atrial but not in ventricular heart muscle

1992

The effects of 5-hydroxytryptamine (5-HT) on force of contraction (FC), action potential (AP) and calcium current (ICa) were studied in human right atrial and left ventricular heart muscle. 5-HT exerted a concentration-dependent increase in FC in multicellular atrial preparations; the EC50 was approximately 3 x 10(-7) mol/l. Maximal increases in FC (252 +/- 58% of control values; mean +/- SEM, n = 6) were obtained at 5-HT 10(-5) mol/l. At this concentration, ICa was increased four- to sevenfold in enzymatically isolated atrial myocytes. In contrast, ventricular preparations did not respond to 5-HT; FC, AP and ICa remained unaffected. In the same preparations, FC was increased by isoprenalin…

AdultMaleInotropeSerotoninmedicine.medical_specialtyHeart VentriclesIn Vitro TechniquesAdenylyl cyclasechemistry.chemical_compoundInternal medicineIsoprenalineHumansMedicineHeart AtriaAtrium (heart)ReceptorAgedPharmacologybusiness.industryMyocardiumIsoproterenolGeneral MedicineMiddle AgedPapillary Musclesmedicine.diseaseMyocardial Contractionmedicine.anatomical_structureEndocrinologychemistryVentricleHeart failureCirculatory systemcardiovascular systemFemaleCalcium Channelsbusinessmedicine.drugNaunyn-Schmiedeberg's Archives of Pharmacology
researchProduct

Modulation of intracortical inhibition induced by low- and high-frequency repetitive transcranial magnetic stimulation.

2001

We studied the changes of duration of subsequent silent periods (SPs) during repetitive magnetic stimulation (rTMS) trains of ten stimuli delivered at low (1 Hz) and high (7 Hz) frequencies. The effects at different intensities of stimulation (motor threshold, MT, 115% and 130% above the MT) were also evaluated. rTMS was performed in eight healthy subjects with a figure-of-eight coil placed over the hand motor area. The SP was recorded from abductor pollicis brevis (APB) muscle during a voluntary contraction of 30% of maximum effort. rTMS at 1-Hz frequency progressively decreased the duration of SP, whereas an alternating pattern of smaller and larger values was observed during trains at 7-…

AdultMaleInterneuronmedicine.medical_treatmentMovementStimulationStimulus (physiology)H-ReflexNuclear magnetic resonanceNeural PathwaysmedicineReaction TimeHumansMuscle SkeletalMotor NeuronsChemistryElectromyographyGeneral NeuroscienceMotor CortexMotor controlNeural InhibitionEvoked Potentials MotorTranscranial Magnetic StimulationElectric StimulationTranscranial magnetic stimulationElectrophysiologymedicine.anatomical_structureSilent periodFemaleNeuroscienceMotor cortexMuscle ContractionExperimental brain research
researchProduct

Human isometric force production and electromyogram activity of knee extensor muscles in water and on dry land.

1999

This study was designed to determine trial-to-trial and day-to-day reproducibility of isometric force and electromyogram activity (EMG) of the knee extensor muscles in water and on dry land as well as to make comparisons between the two training conditions in muscle activity and force production. A group of 20 healthy subjects (12 women and 8 men) were tested three times over 2 weeks. A measurement session consisted of recordings of maximal and submaximal isometric knee extension force with simultaneous recording of surface EMG from the vastus medialis, vastus lateralis and biceps femoris muscles. To ensure identical measurement conditions the same patient elevator chair was used in both th…

AdultMaleKnee JointPhysiologyVastus medialisIntraclass correlationIsometric exerciseElectromyographyBicepsIsometric ContractionMedicineHumansMuscle SkeletalHydrotherapyReproducibilityKnee extensorsmedicine.diagnostic_testbusiness.industryElectromyographyPublic Health Environmental and Occupational HealthReproducibility of ResultsWaterAnatomyElectrophysiologyFemalebusinessBiomedical engineeringEuropean journal of applied physiology and occupational physiology
researchProduct

Electromechanical behaviour of human muscles in vertical jumps

1982

The relationships of muscle structure to the potentiation of myoelectrical activity and to the use of prestretching in five lower limb muscles were studied in different vertical jumping conditions. The subjects for the study were six male students, divided according to the muscle fiber distribution in m. vastus lateralis into “fast” and “slow” groups. The subjects performed vertical jumps (1) from a static squatting position (SJ), (2) with a preliminary counter movement (CMJ) and (3) after dropping (DJ) from five different heights. Myoelectrical (EMG) activity was recorded from mm. gluteus maximus, vastus lateralis, vastus medialis, rectus femoris and gastrocnemius in each jumping condition…

AdultMaleKnee JointPhysiologyVastus medialisMovementElectromyographyConcentricSports Medicinemedicine.disease_causeJumpingPhysiology (medical)medicineHumansEccentricOrthopedics and Sports MedicineMuscle fibreLegmedicine.diagnostic_testElectromyographyChemistryMusclesTrack and FieldPublic Health Environmental and Occupational HealthGeneral MedicineAnatomymusculoskeletal systemVertical jumpingbody regionsSquatting positionMuscle ContractionEuropean Journal of Applied Physiology and Occupational Physiology
researchProduct

Effects of a 21 days space flight on the mechanical performance and the EMG power spectrum of the leg muscles

2002

AdultMaleLegMaterials scienceElectromyographyWeightlessnessBiomedical EngineeringSpectral densitySignal Processing Computer-AssistedSpace Flightmaximal power; space fligth; microgravitySpaceflightmicrogravitylaw.inventionLeg musclespace fligthlawReference Valuesmaximal powerIsometric ContractionExercise TestHumansMuscle SkeletalSimulation
researchProduct

Electromechanical delay in human skeletal muscle under concentric and eccentric contractions.

1979

In contraction of skeletal muscle a delay exists between the onset of electrical activity and measurable tension. This delay in electromechanical coupling has been stated to be between 30 and 100 ms. Thus, in rapid movements it may be possible for electromyographic (EMG) activity to have terminated before force can be detected. This study was designed to determine the dependence of the EMG-tension delay upon selected initial conditions at the time of muscle activation. The right forearms of 14 subjects were passively oscillated by a motor-driven dynamometer through flexion-extension cycles of 135 deg at an angular velocity of approximately equal to 0.5 rad/s. Upon presentation of a visual s…

AdultMaleLightPhysiologyMovementBrachioradialisIsometric exerciseConcentricBicepsPhysiology (medical)medicineEccentricHumansOrthopedics and Sports MedicinePhysicsMusclesPublic Health Environmental and Occupational HealthSkeletal muscleGeneral MedicineAnatomyElectrophysiologyElectrophysiologymedicine.anatomical_structuremedicine.symptomBiomedical engineeringMuscle contractionMuscle ContractionEuropean journal of applied physiology and occupational physiology
researchProduct

Muscle kinematics during isometric contraction: Development of phase contrast and spin tag techniques to study healthy and atrophied muscles

2004

Purpose To develop and compare phase-contrast (PC) and spin-tag (ST) MR imaging techniques for accurate quantification of velocity and displacement distribution in the muscle tendon complex of the lower leg during isometric contractions under in vivo conditions, in healthy subjects and subjects with atrophy. Materials and Methods Techniques were developed to acquire PC and ST dynamic images, gated to the force exerted by a subject during isometric contraction. Algorithms were optimized for correction of phase shading errors. Flow velocity quantification was validated in phantoms and ex vivo rabbit muscles. Trajectories of pixels calculated from PC images were compared with those in ST image…

AdultMaleMagnetic Resonance Imaging CineIsometric exerciseKinematicsDisplacement (vector)In vivoIsometric ContractionImage Processing Computer-AssistedmedicineAnimalsHumansRadiology Nuclear Medicine and imagingMuscle SkeletalPhysicsLegPhantoms ImagingBiomechanicsAnatomyMuscle atrophyBiomechanical PhenomenaHindlimbTendonMuscular Atrophymedicine.anatomical_structureFlow velocityFemaleRabbitsmedicine.symptomBiomedical engineeringJournal of Magnetic Resonance Imaging
researchProduct

Muscle tone in different joint positions and at submaximal isometric torque levels

2007

The aim was to evaluate the tone and electric activity of the quadriceps muscle at rest and different torque levels. The second aim was to study whether thickness of soft tissues and change in the joint position would affect muscle tone. Eighteen healthy subjects participated. Computerized muscle tonometer (CMT) and surface electromyography (sEMG) measurements were performed: seated, first at rest with leg straight and then with the knee at 60 degrees . Thereafter measurements were obtained at levels of 80, 60, 40 and 20% of the maximum isometric torque at the same knee angle. Thickness of skin, subcutis and muscle was measured by ultrasound. The CMT values taken were the depth the indenter…

AdultMaleManometryPhysiologyBiomedical EngineeringBiophysicsElectromyographyTone (musical instrument)Muscle toneIsometric ContractionPhysiology (medical)medicineHumansTorqueMuscle Skeletalmedicine.diagnostic_testElectromyographybusiness.industryUltrasoundWork (physics)Soft tissueRepeatabilityAnatomyBiomechanical PhenomenaElectrophysiologyCross-Sectional Studiesmedicine.anatomical_structureData Interpretation StatisticalMuscle TonusFemaleJointsbusinessBiomedical engineeringPhysiological Measurement
researchProduct

Effects of different electrical stimulation currents and phase durations on submaximal and maximum torque, efficiency, and discomfort: a randomized c…

2021

Abstract Background Neuromuscular electrical stimulation (NMES) is an important therapeutic tool for rehabilitation. However, best stimulation parameters remain to be determined. Objective To determine the influence of different electrical stimulation currents and phase durations on torque, efficiency, and discomfort. Methods Using a cross-over design, kHz frequency alternating currents (KFAC) and pulsed currents (PC) with narrow (200 µs) or wide (500 µs) phase durations were randomly applied on knee extensor muscles of healthy participants with a minimum of seven days between sessions. The NMES-evoked torque, NMES-efficiency, and discomfort (visual 0−10 cm analogue scale) were measured for…

AdultMaleMaterials scienceAdolescentPhase (waves)Physical Therapy Sports Therapy and RehabilitationStimulationElectric Stimulation TherapyQuadriceps Muscle03 medical and health sciencesYoung Adult0302 clinical medicineIsometric ContractionTorqueHumansOrthopedics and Sports MedicineKneeMuscle SkeletalOriginal ResearchCross-Over StudiesKnee extensorsRehabilitation030229 sport sciencesCrossover studyElectric StimulationIntensity (physics)Phase durationTorqueMaximum torque030217 neurology & neurosurgeryBiomedical engineeringBrazilian journal of physical therapy
researchProduct

Contribution of the tendinous tissue to force enhancement during stretch–shortening cycle exercise depends on the prestretch and concentric phase int…

2005

When the prestretch intensity and concentric work are increased in stretch-shortening cycle (SSC) exercises, the utilization of the elastic energy can increase during the concentric phase. In order to further understand this process during SSC exercises, the interaction between fascicle-tendinous tissues (TT) of the vastus lateralis (VL) muscle was examined under different prestretch and rebound intensity drop jumps. Ten male subjects participated in the study. Direct VL fascicle lengths (N = 10) and in vivo patellar tendon force (N = 1) were measured together with the electromyographic (EMG) activity of VL during the trials. With increasing drop height but the same rebound height condition…

AdultMaleMaterials scienceKnee JointMovementPhysical ExertionBiophysicsNeuroscience (miscellaneous)Phase (waves)ConcentricTendonsHumansExercise physiologyMuscle SkeletalExerciseTension (physics)Work (physics)AnatomyFascicleAdaptation PhysiologicalIntensity (physics)body regionsStretch-Shortening Cycle ExerciseStress MechanicalNeurology (clinical)Muscle ContractionBiomedical engineeringJournal of Electromyography and Kinesiology
researchProduct