Search results for "CONTRAST"
showing 10 items of 1162 documents
Transarterial Chemoembolization in Patients Not Eligible for Liver Transplantation: Single-Center Results
2008
OBJECTIVE. The purpose of this study was to evaluate the effectiveness of transarterial chemoembolization in the care of patients not eligible for liver transplantation.CONCLUSIONS. Prognosis depends on local response, Okuda score, α-fetoprotein level, and tumor size and is independent of the presence of portal venous thrombosis.
Evaluation of posttreatment response of hepatocellular carcinoma: comparison of ultrasonography with second-generation ultrasound contrast agent and …
2010
We evaluated the ability of one-month follow-up contrast-enhanced ultrasound (CEUS) with second-generation contrast agent in monitoring radio frequency ablation (RFA) and transcatheter arterial chemoembolization (TACE) treatments of hepatocellular carcinoma (HCC). One-hundred forty-eight HCCs were studied using CEUS: 110 nodules were treated with RFA [41/110 RFA were performed using a pretreatment and an immediate postablation evaluation using CEUS (group 1); 69/110 using only US guidance (group 2)] and 38 nodules treated with TACE. For statistical analysis, McNemar test was used. Overall complete response was observed in 107/148 nodules (92/110 treated with RFA and 15/38 with TACE). A bett…
Contrast echocardiography of the left ventricle an independent predictor of pulmonary artery pressure?
1994
To test the hypothesis that left heart opacification is dependent on pulmonary artery pressure, we analyzed consecutively 12 patients with normal and 8 patients with abnormal pulmonary artery pressure with a new lung capillary stable echo contrast agent. Patients underwent contrast echocardiographic examination within 6 hours before right and left heart catheterization with 200 mg/ml and 400 mg/ml SHU 508A intravenously. The mean pulmonary artery pressure was 15.4 mmHg in the patients with normal pulmonary artery pressures and 46.4 mmHg in the patients with pulmonary hypertension (p0.000). Echocardiograms were video-intensitometrically analyzed for intensity maximum (MAX), half-time of vide…
Parametric assessment of myocardial perfusion during interventional cardiac catheterization by means of X-ray densitometry-short-and long-term result…
1990
X-ray densitometric evaluation of digital subtraction angiocardiograms allows an assessment of myocardial perfusion by means of the parameter 'MEAN RISE TIME' (MRT), defined as the time from the onset of local myocardial contrast medium opacification to the point of maximum opacification. Best results are obtained when the response of that parameter is compared before and after stimulation of coronary flow by papaverine. A prolongation of this parameter, especially after papaverine, was indicative of an impairment of myocardial perfusion, when compared to the results of TL-201 scintigraphy. In 50 patients with single vessel coronary artery disease the results of MRT pre and post papaverine …
The effect of balloon dilatation on post-stenotic myocardial perfusion before and after stimulation of coronary flow reserve: evaluation by the densi…
1988
From densitometric evaluation of digital subtraction cineangiocardiograms the parameter 'Mean Rise Time' (MRT), defined as the time from the onset of local myocardial contrast medium opacification to the point of maximal opacification can be derived; this parameter revealed a close correlation with the results on myocardial perfusion obtained by Thallium-201 scintigraphy. A prolonged 'Mean Rise Time' was indicative of an impairment of myocardial perfusion. We have developed a heart-phase gated real-time digitization procedure and computer-supported method for the densitometric estimation of the MRT to obtain information about the effect of coronary balloon dilatation on myocardial perfusion…
Colorectal Polyps: Detection with Dark-Lumen MR Colonography versus Conventional Colonoscopy
2005
To prospectively compare dark-lumen magnetic resonance (MR) colonography with conventional colonoscopy in the detection of colorectal polyps.Local ethical committee approval and informed consent were obtained. One hundred consecutive patients (56 men, 44 women; mean age +/- standard deviation, 67.7 years +/- 14.7; range, 25-82 years) who were referred for conventional colonoscopy from January 2003 to January 2004 underwent MR colonography and conventional colonoscopy after standard precolonoscopic bowel cleansing. Colonoscopy was performed immediately after MR colonography. For MR colonography, the colon was filled with approximately 2000 mL of tap water. Imaging was performed with a 1.5-T …
A multicenter, site-independent, blinded study to compare the diagnostic accuracy of contrast-enhanced magnetic resonance angiography using 1.0M gado…
2007
Abstract Purpose Prospective evaluation of diagnostic accuracy of single field-of-view contrast-enhanced MR Angiography (ceMRA) with 1.0 M gadobutrol compared to intraarterial DSA in body arteries. Materials and methods In an European multicenter study 179 patients underwent ceMRA and DSA. For each indication five prospectively defined vessel segments were evaluated by local investigators onsite and by three site-independent blinded readers (BR) independently. Results The agreement between ceMRA and DSA diagnosis was statistically significant in the onsite (96.6%) and blinded reader (86.6–90.2%) evaluation. Sensitivity, specificity, accuracy, positive (PPV) and negative predictive values (N…
Resovist enhanced MR imaging of the liver: Does quantitative assessment help in focal lesion classification and characterization?
2009
Purpose: To improve characterization of focal liver lesions by a prospective quantitative analysis of percentage signal intensity change, in dynamic and late phases after slow (0.5 mL/s) Resovist administration. Materials and Methods: Seventy-three patients were submitted on clinical indication to MR examination with Resovist. Signal intensity of 92 detected focal lesions (5–80 mm) were measured with regions of interest and normalized to paravertebral muscle in arterial, portal, equilibrium and T1/T2 late phases, by two observers in conference. Five values of percentage variations per patient were obtained and statistically evaluated. Results: The enhancement obtained on dynamic study is mo…
Diagnostic performance of gadobenate dimeglumine enhanced MR angiography of the iliofemoral and calf arteries: a large-scale multicenter trial
2007
OBJECTIVE. The purpose of this study was to compare gadobenate dimeglumine–enhanced MR angiography and unenhanced time-of-flight MR angiography for the detection of significant peripheral arterial occlusive disease using digital subtraction angiography as our reference standard. SUBJECTS AND METHODS. Two hundred seventy-two patients underwent MR angiography and digital subtraction angiography of the iliofemoral arteries. MR angiography was performed before (2D time-of-flight acquisitions) and after (spoiled gradient-echo acquisitions) the administration of 0.1 mmol/kg of gadobenate dimeglumine at 1–2 mL/s. Contrast-enhanced MR angiography and digital subtraction angiography of the calf arte…
Assessment of the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level in patients with emphysema.
2006
Abstract Purpose To assess the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level using CT and MRI in patients with emphysema. Material and methods Forty-five patients with severe emphysema (GOLD III and IV) underwent inspiratory 3D-HRCT and contrast-enhanced MR-perfusion (1.5T; 3.5 mm × 1.9 mm × 4 mm). 3D-HRCT data was analyzed using a software for detection and visualization of emphysema. Emphysema was categorized in four clusters with different volumes and presented as overlay on the CT. CT and lung perfusion were visually analyzed for three lobes on each side using a four-point-score to grade the abnormalities on CT (1: predominantly smal…