Search results for "CONTRAST"

showing 10 items of 1162 documents

CEUS in the differential diagnosis between biliary sludge, benign lesions and malignant lesions

2017

Abstract PURPOSE: Conventional grayscale ultrasound (US) is accurate in the diagnosis of gallbladder disease (GD), but in some cases, it is not decisive. Contrast-enhanced ultrasound (CEUS) improves the diagnostic accuracy of US. The primary objective of this study is to assess the reliability of CEUS in the diagnosis of sludge; the secondary objective is to assess the ability of CEUS to diagnose cancer. METHODS: We retrospectively reviewed the US of 4137 patients positive for GD. In 43/4137 (1.04%), the use of could not discriminate between sludge and neoplasms. Then, we evaluated CEUS in only 39 of these patients, and in 4/43 (9%) cases it was not performable. After CEUS, the absence of e…

AdultMalemedicine.medical_specialtySettore MED/09 - Medicina InternaGallbladder diseaseContrast MediaGallbladder DiseasesMalignancySensitivity and SpecificitySludge030218 nuclear medicine & medical imagingDiagnosis Differential03 medical and health sciences0302 clinical medicineUltrasoundInternal MedicinemedicineBileHumansRadiology Nuclear Medicine and imagingBiliary sludgeMalignant diseaseAgedRetrospective StudiesUltrasonographybusiness.industryGallbladderCarcinomaUltrasoundBenign diseaseReproducibility of ResultsGallbladderWashoutCancerGeneral MedicineMiddle Agedmedicine.diseasemedicine.anatomical_structure030220 oncology & carcinogenesisCEUSFemaleOriginal ArticleRadiologyDifferential diagnosisbusinessJournal of Ultrasound
researchProduct

Imaging findings of hepatic focal nodular hyperplasia in men and women: are they really different?

2014

Purpose This study was undertaken to compare the imaging findings of focal nodular hyperplasia (FNH) in men and women, as seen on multidetector computed tomography (MDCT), magnetic resonance imaging (MRI) and contrast-enhanced ultrasound (CEUS). Materials and methods Two radiologists reviewed 195 imaging studies (17 MDCT, 81 MRI and 97 CEUS examinations) pertaining to 111 FNHs (mean size 3 cm) in 91 patients (mean age 39 years). For each lesion, the readers assessed size, location, echogenicity, attenuation, or signal intensity in comparison with adjacent liver parenchyma on both unenhanced and postcontrast images. Results Eighty-nine FNHs (mean size 3.1 cm) were observed in 73 women (mean …

AdultMalemedicine.medical_specialtySulfur HexafluorideContrast MediaSettore MED/01 - Statistica MedicaMeglumineSex FactorsSex factorsMultidetector computed tomographyMultidetector Computed TomographyOrganometallic CompoundsMedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesPhospholipidsNeuroradiologyAgedmedicine.diagnostic_testbusiness.industryUltrasoundFocal nodular hyperplasiaMagnetic resonance imagingInterventional radiologyGeneral MedicineMiddle Agedmedicine.diseaseMagnetic Resonance ImagingFocal nodular hyperplasia liver Computed tomographyMagnetic resonance imagingContrast-enhanced ultrasoundIopamidolFocal Nodular Hyperplasiacardiovascular systemFemaleRadiologybusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaContrast-enhanced ultrasound
researchProduct

Ultrasonic evaluation with second harmonic imaging and SonoVue in the assessment of cerebral perfusion in diabetic patients: a case-control study

2004

The purpose was to compare human brain tissue perfusion in diabetic patients and healthy subjects with second harmonic imaging ultrasound and SonoVue to test the hypothesis that brain tissue perfusion differences are present in these two groups of patients. In a prospective case-control study, second harmonic examinations performed in 20 patients with type II diabetes mellitus and in 20 matched control patients were compared. After administration of 2.5 ml of SonoVue, 60 time-triggered images were recorded. Time-intensity curves, including peak intensity and positive gradient normalized to the middle cerebral artery, were calculated to quantify ultrasound intensity in a region of interest. …

AdultMalemedicine.medical_specialtySulfur Hexafluoridemedicine.arteryInternal medicineUltrasoundHumansMedicineRadiology Nuclear Medicine and imagingProspective StudiesCerebral perfusion pressurePhospholipidsAgedUltrasonographyNeuroradiologyHarmonic studybusiness.industryContrast mediaUltrasoundCase-control studyBrainGeneral MedicineBlood flowBlood flowMiddle AgedSurgeryIntensity (physics)PerfusionDiabetes Mellitus Type 2Case-Control StudiesCerebrovascular CirculationMiddle cerebral arteryCardiologyFemaleRadiologybusinessPerfusion
researchProduct

Plantar fascia evaluation with a dedicated magnetic resonance scanner in weight-bearing position: our experience in patients with plantar fasciitis a…

2010

Purpose. This study assessed the usefulness of upright weight-bearing examination of the ankle/hind foot performed with a dedicated magnetic resonance (MR)imaging scanner in the evaluation of the plantar fascia in healthy volunteers and in patients with clinical evidence of plantar fasciitis. Materials and methods. Between January and March 2009, 20 patients with clinical evidence of plantar fasciitis (group A) and a similar number of healthy volunteers (group B) underwent MR imaging of the ankle/hind foot in the upright weight-bearing and conventional supine position. A 0.25-Tesla MR scanner (G-Scan, Esaote SpA, Genoa, Italy) was used with a dedicated receiving coil for the ankle/hind foot…

AdultMalemedicine.medical_specialtySupine positionPlantar fasciitisContrast Mediamedicine.disease_causePatient PositioningWeight-bearingWeight-BearingPlantar fascia · MRI · Weight-bearingImage Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingNeuroradiologymedicine.diagnostic_testbusiness.industryUltrasoundMagnetic resonance imagingGeneral MedicineMiddle AgedMagnetic Resonance Imagingbody regionsmedicine.anatomical_structureFasciitis PlantarPlantar fasciaFemaleRadiologyAnklemedicine.symptombusinessLa Radiologia medica
researchProduct

Centrifugal (inside-out) enhancement of liver hemangiomas: a possible atypical appearance on contrast-enhanced US.

2007

Abstract Objective To report the prevalence and to describe the atypical centrifugal (inside-out) appearance of contrast-enhancement of liver hemangiomas on contrast-enhanced sonography. Materials and methods Baseline and SonoVue ® -enhanced ultrasonography of 92 patients with 158 liver hemangiomas – considered atypical at grey-scale examination and confirmed by computed tomography, magnetic resonance imaging and ultrasound follow-up – were reviewed in consensus by two experienced radiologists, who evaluated baseline echogenicity and the dynamic enhancement pattern of each lesion looking for the presence of central enhancing foci in the arterial phase followed by a centrifugal (inside-out) …

AdultMalemedicine.medical_specialtyTime FactorsSecond-harmonic imaging microscopySulfur HexafluorideContrast MediaAngiomaHepatic ArterymedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingUltrasonography Doppler ColorPhospholipidsAgedMicrobubblesmedicine.diagnostic_testbusiness.industryVascular diseasePortal VeinUltrasoundLiver NeoplasmsEchogenicityMagnetic resonance imagingUltrasonography DopplerGeneral MedicineMiddle Agedmedicine.diseaseImage EnhancementMagnetic Resonance ImagingUltrasonography Doppler PulsedLiver HemangiomaFemaleRadiologyTomographybusinessHemangiomaTomography X-Ray ComputedFollow-Up StudiesEuropean journal of radiology
researchProduct

Choice of spatial frequency for contrast sensitivity evaluation after corneal refractive surgery.

2002

ABSTRACT PURPOSE: To study the utility of measurements of contrast sensitivity at different spatial frequencies as an index of visual recovery following refractive surgery. METHODS: Contrast sensitivity at 1.5, 3, 6, 12, and 18 c/deg was measured with the Stereo Optical FACT chart in 20 patients after photorefractive keratectomy (PRK) using the Nidek EC-5000 excimer laser system, and in 18 patients following laser in situ keratomileusis (LASER). Contrast sensitivity was measured preoperatively and 1, 3, 6, and 12 months after surgery. RESULTS: Results showed a statistically significant reduction (P<01) in contrast sensitivity at all spatial frequencies in PRR patients during the first an…

AdultMalemedicine.medical_specialtyTime Factorsgenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityKeratomileusisExcimerPhotorefractive Keratectomylaw.inventionContrast SensitivityCornealawOphthalmologyRefractive surgerymedicineMyopiaContrast (vision)Humansmedia_commonbusiness.industryLASIKLasereye diseasesPhotorefractive keratectomySurgeryOphthalmologySurgeryFemaleLasers Excimersense organsSpatial frequencybusinessJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Differences in visual performance of AcrySof ReSTOR IOL in high and low myopic eyes.

2009

PURPOSE To determine the differences in refractive and visual results obtained in eyes with high and low myopia after multifocal intraocular lens (IOL) implantation. METHODS Monocular visual acuity for distance and near, with and without distance correction, and photopic and mesopic contrast sensitivity were measured at 6 months after surgery in 152 myopic eyes implanted with the AcrySof ReSTOR Natural (SN60D3) IOL. Two groups were created: high and low myopia (76 eyes in each). RESULTS Monocular best distance-corrected visual acuity was 0.02+/-0.06 logMAR for low myopes and 0.05+/-0.09 logMAR for high myopes. Monocular best distance-corrected near visual acuity was 0.04+/-0.05 and 0.07+/-0…

AdultMalemedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiaMesopic visionmedia_common.quotation_subjectProsthesis DesignRefraction OcularSeverity of Illness IndexContrast Sensitivity03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaContrast (vision)HumansProspective Studiesmedia_commonAgedLenses IntraocularMonocularbusiness.industryGeneral MedicineMultifocal intraocular lensMiddle AgedDistance correctioneye diseasesOphthalmologyTreatment Outcome030221 ophthalmology & optometryFemalesense organsSpatial frequencymedicine.symptombusiness030217 neurology & neurosurgeryPhotopic visionEuropean journal of ophthalmology
researchProduct

Visual quality differences between orthokeratology and LASIK to compensate low-moderate myopia.

2013

PURPOSE: To assess the differences in visual performance between orthokeratology (ortho-k) and laser in situ keratomileusis (LASIK) for the treatment of low-to-moderate myopia. METHODS: An adaptive optics visual simulator (Imagine Eyes) was used to simulate the wavefront aberration patterns induced by ortho-k and LASIK for low and moderate myopia on 10 healthy eyes. Visual acuity (VA) at 100%, 50%, and 10% contrast levels and contrast sensitivity (CS) at 10, 20 and 25 cycles per degree (cpd) were then measured for 3- and 6-mm pupil sizes. RESULTS: Differences in VA for 3-mm pupil diameter were not found between ortho-k and LASIK. For 6-mm pupil size, LASIK provided significantly better VA v…

AdultMalemedicine.medical_specialtyVisual acuitymedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityKeratomileusisPupilCycles per degreeContrast SensitivityYoung AdultOphthalmologyMyopiaMedicineContrast (vision)Humansmedia_commonAnalysis of Variancebusiness.industryOrthokeratologyPupil sizeLASIKOphthalmologyFemalemedicine.symptombusinessOrthokeratologic ProceduresCornea
researchProduct

Vision evaluation in people with Down's syndrome.

1994

We tested the colour vision of 72 people with Down's syndrome using the Ishihara test and an anomaloscope. We found that 13 of the subjects, 6 males and 7 females, had defective colour vision according to Pickford's classification. In monocular vision 10 eyes were protan (five simple, three extreme and two deviant), one eye was simple deuteranomalous and the remaining eyes were normal: in binocular vision four of the subjects were protan (two simple and two deviant), two subjects were deutan (one simple and one deviant) and the rest were normal. Many of our subjects had lens opacities, strabismus, nystagmus, hypermetropia, high myopia and astigmatism, confirming literature reports. The cont…

AdultMalemedicine.medical_specialtygenetic structuresAdolescentColor visionColor Vision DefectsNystagmusAstigmatismAudiologyCataractNystagmus PathologicDevelopmental psychologyVision disorderContrast SensitivityVision MonocularmedicineHumansStrabismusChildVision Binocularmedicine.diseaseRefractive Errorseye diseasesSensory SystemsAnomaloscopeStrabismusOphthalmologyFemalemedicine.symptomDown SyndromePsychologyBinocular visionMonocular visionOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lens

2007

To assess visual results after symmetrical bilateral implantation of a distance-dominant bifocal diffractive intraocular lens (IOL).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Fifty patients had bilateral implantation of a distance-dominant diffractive bifocal 447D IOL (Acri.Tec GmbH) in a prospective study. Monocular and binocular best corrected distance visual acuities and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 6-month postoperative visit, the mean binocular best corrected distance acuity and…

AdultMalemedicine.medical_specialtygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensContrast SensitivityNear acuityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularDepth PerceptionVision BinocularPhacoemulsificationMonocularbusiness.industryDistance PerceptionPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyPostoperative visitOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct