Search results for "CPA"
showing 10 items of 53 documents
The mutagenicity of MCPA and its soil metabolites, chlorinated phenols, catechols and some widely used slimicides in Finland
1977
Acute and subchronic toxicity of 2-methyl-4-chlorophenoxyacetic acid (MCPA) in male rat. I. Light microscopy and tissue concentrations of MCPA.
1977
Magnetic molecularly imprinted polymer for the simultaneous selective extraction of phenoxy acid herbicides from environmental water samples
2022
[EN] A selective magnetic molecularly imprinted polymer (MMIP) was synthetized with 4-chloro-2-methylphenoxyacetic acid as template and 4-vinylpiridine as monomer in presence of vinylized magnetite nanoparticles. Scanning electron microscopy, nitrogen adsorption-desorption isotherms, Fourier transform infrared spectrometry and vibrating sample magnetometry were applied to characterize the resulting material. The synthesized MMIP was applied as sorbent in magnetic molecularly imprinted solid-phase extraction (MMISPE) for selective extraction of a mixture of the five herbicides 4-chloro-2-methylphenoxyacetic acid (MCPA), 4-(4-chloro-2-methylphenoxy)butyric acid (MCPB), mecoprop (MCPP), fenoxa…
A comparison of the effects of ?-ketotriazole, MCPA and carbaryl on the plasma membrane Mg2+-ATPase activity and lipid composition of rice shoots (Or…
1993
The effect of γ-ketotriazole, MCPA and carbaryl on the lipid composition and ATPase activity associated with plasma membrane fractions from rice (Oryza sativa cv Bahia) shoots was investigated. With γ-ketotriazole and MCPA treatments the relative amount of δ5-avenasterol (%) was reduced in the plasma membrane, whereas with γ-ketotriazole a reduction was also found in the sitosterol content, expressed as a percentage of the total free sterol composition. The fatty acyl chain length of phosphatidylcholine fractions from MCPA-treated plants was also reduced. The plasma membrane Mg2+-ATPase activity was only stimulated in MCPA-treated plants. No changes were observed in lipid composition or ATP…
Proceedings of the Ninth International Conference on Soft Computing and Pattern Recognition (SoCPaR 2017)
2018
This book presents 18 carefully selected papers from the ninth edition of the International Conference on Soft Computing and Pattern Recognition (SoCPaR 2017), which was held in Marrakesh, Morocco from December 11 to 13, 2017. A premier conference in the Soft Computing field, SoCPaR brings together the world’s leading researchers and practitioners interested in advancing the state of the art in Soft Computing and Pattern Recognition, allowing them to exchange notes on a broad range of disciplines. The book offers a valuable reference guide for all researchers, students and practitioners in the fields of Computer Science and Engineering
Noninvasive respiratory support in the hypoxaemic peri-operative/periprocedural patient: A joint ESA/ESICM guideline.
2020
Hypoxaemia is a potential life-threatening yet common complication in the peri-operative and periprocedural patient (e.g. during an invasive procedure at risk of deterioration of gas exchange, such as bronchoscopy). The European Society of Anaesthesiology (ESA) and the European Society of Intensive Care Medicine (ESICM) developed guidelines for the use of noninvasive respiratory support techniques in the hypoxaemic patient in the peri-operative and periprocedural period. The panel outlined five clinical questions regarding treatment with noninvasive respiratory support techniques [conventional oxygen therapy (COT), high flow nasal cannula, noninvasive positive pressure ventilation (NIPPV) a…
Treatment options in obstructive sleep apnea
2022
AbstractTreatment of OSA with CPAP is currently the recommended treatment and has the greatest evidence of efficacy on AHI, symptoms and comorbidities. Symptomatic patients with moderate-severe OSA generally have good adherence to CPAP therapy, while those with mild OSA, female, young and generally paucisymptomatic, have lower CPAP adherence, especially in the medium and long term. The recent identification of different clinical and pathophysiological phenotypes of OSA has paved the way for alternative treatments to CPAP, leading to an increasingly personalized therapy. Weight loss and lifestyle modifications are highly recommended in all obese or overweight patients. Mandibular advancement…
A New Configuration for Helmet Continuous Positive Airway Pressure Allowing Tidal Volume Monitoring
2020
We performed a bench and human study to test the hypothesis that a ventilator can accurately estimate Vt when a helmet is used in CPAP mode in a single limb configuration with an intentional leak port placed at the helmet expiratory port. We have recently demonstrated the effectiveness of this setup in bilevel mode
Performance of helmet CPAP using different configurations: Turbine-driven ventilators vs Venturi devices
2023
Background Traditionally, Venturi-based flow generators have been preferred over mechanical ventilators to provide continuous positive airway pressure (CPAP) through the helmet (h-CPAP). Recently, modern turbine-driven ventilators (TDVs) showed to be safe and effective in delivering h-CPAP. We aimed to compare the pressure stability during h-CPAP delivered by Venturi devices and TDVs and assess the impact of High Efficiency Particulate Air (HEPA) filters on their performance. Methods We performed a bench study using an artificial lung simulator set in a restrictive respiratory condition, simulating two different levels of patient effort (high and low) with and without the interposition of t…
Effectiveness and safety of a new helmet CPAP configuration allowing tidal volume monitoring in patients with COVID-19.
2021
Abstract Background High generated tidal volumes (Vt) have been correlated with higher risk of self-induced lung injury and worse clinical outcome. This study aimed to evaluate the effectiveness and safety of a new helmet continuous positive airway pressure delivered (h-CPAP) configuration allowing Vt monitoring in patients affected by COVID-19. Methods This prospective observational study was performed in the respiratory intermediate care unit of University Hospital in Turin, Italy, between March 24th, and June 15th, 2020. Included patients were treated with CPAP via a single-limb intentional leak configuration by a turbine-driven ventilator, provided with a dedicated patch. Effectiveness …