Search results for "CUF"

showing 10 items of 63 documents

Ultrasound-guided musculoskeletal interventional procedures around the shoulder

2021

Ultrasound is a fast, accessible, reliable, and radiation-free imaging modality routinely used to assess the soft tissues around the shoulder. It enables to identify a wide range of pathological conditions. Furthermore, most ultrasound-guided musculoskeletal interventional procedures around the shoulder produce better results in terms of accuracy and clinical efficacy than those performed in a blinded fashion. Indeed, intra-articular and peri-articular interventional procedures can be easily performed under continuous ultrasound monitoring to ensure the correct position of the needle and to deliver the medication to a specific target. Several technical approaches and medications can be used…

medicine.medical_specialtyDry needlingRadiological and Ultrasound TechnologyBursitismedicine.diagnostic_testbusiness.industryshoulderultrasoundUltrasoundInterventional radiologyOsteoarthritisSuprascapular nervemedicine.diseaseCapsulitismedicine.anatomical_structureinterventional radiologymedicineMedicineRadiology Nuclear Medicine and imagingRotator cuffRadiologybusinessinjectionsJournal of Ultrasonography
researchProduct

Niederfeld MR-Arthrographie der Schulter: Erste Ergebnisse mit einem offenen 0,2 T MR-System

1998

PURPOSE To assess the practicability and image quality of doing MR arthrography of the shoulder using a 0.2T system. PATIENTS AND METHOD 60 patients (24 with chronic instability, 36 with impingement syndrome) were examined in an open 0.2T MR apparatus (Magnetom Open, Siemens). After the intra-articular injections of 15-20 ml of a 2 mmol Gd-DTPA solution, coronary STIR, T1-weighted, sagittal and axial T2*-weighted FLASH 2D sequences were performed. 21 patients subsequently underwent surgery. RESULTS Image quality of the T1- and T2*-weighted FLASH 2D sequences was regarded as good or adequate and movement artifacts were minor or moderate. STIR sequences were statistically significantly worse …

medicine.medical_specialtyLabrummedicine.diagnostic_testbusiness.industryImage qualityImpingement syndromeMagnetic resonance imagingmedicine.diseaseSagittal planeSurgerymedicine.anatomical_structuremedicineRotator cuff ruptureRadiology Nuclear Medicine and imagingShoulder jointRotator cuffNuclear medicinebusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Correlation of skeletal muscle blood oxygenation level-dependent MRI and skin laser doppler flowmetry in patients with systemic sclerosis

2013

Purpose To investigate the origin of skeletal muscle BOLD MRI alterations in patients with systemic sclerosis (SSc) by correlating BOLD MRI T2* signal of calf muscles with microcirculatory blood flow of calf skin measured by laser Doppler flowmetry (LDF). Materials and Methods BOLD MRI (3T) and LDF measurements were performed in 12 consecutive SSc patients (6 women, 6 men; mean age 54.0 ± 10.0 years) and 12 healthy volunteers (4 men, 8 women; mean age 44.7 ± 13.1 years). For both modalities, the same cuff compression paradigm at mid-thigh level was used. LDF datasets were acquired using a PeriScan PIM II Imager (Perimed AB, Stockholm, Sweden) at the upper calf corresponding to the level of …

medicine.medical_specialtyPathologyintegumentary systembusiness.industryBlood oxygenation level dependentSkeletal muscleBlood flowLaser Doppler velocimetryCorrelationmedicine.anatomical_structureInternal medicineCuffmedicineCardiologyRadiology Nuclear Medicine and imagingIn patientbusinessPerfusionJournal of Magnetic Resonance Imaging
researchProduct

Steep blood pressure increase in low birth weight newborns

2004

medicine.medical_specialtyPregnancyObstetricsbusiness.industryBirth weightmedicine.diseaseCatheter cuffsLow birth weightBlood pressureInternal Medicinemedicinemedicine.symptomBlood pressure increasebusinessAmerican Journal of Hypertension
researchProduct

Reliability of isokinetic assessment of shoulder-rotator strength: a systematic review of the effect of position.

2011

Context:Isokinetic assessment of shoulder internal- (IR) and external-rotator (ER) strength is commonly used with many different postures (sitting, standing, or supine) and shoulder positions (frontal or scapular plane with 45° or 90° of abduction).Objective:To conduct a systematic review to determine the influence of position on the intersession reliability of the assessment of IR and ER isokinetic strength, to identify the most reliable position, and to determine which isokinetic variable appears to be most stable in intersession reliability.Evidence Acquisition:A systematic literature search through MEDLINE and Pascal Biomed databases was performed in October 2009. Criteria for inclusion…

medicine.medical_specialtyShoulderSupine positionIntraclass correlationPostureBiophysicsPhysical Therapy Sports Therapy and RehabilitationContext (language use)Sitting03 medical and health sciencesRotator Cuff0302 clinical medicinePhysical medicine and rehabilitationMedicineHumansOrthopedics and Sports MedicineMuscle Strength10. No inequalityReliability (statistics)030222 orthopedicsbusiness.industry[SCCO.NEUR]Cognitive science/NeuroscienceRehabilitation[SCCO.NEUR] Cognitive science/NeuroscienceReproducibility of Results030229 sport sciencesPosition (obstetrics)Coronal plane[ SCCO.NEUR ] Cognitive science/NeurosciencebusinessEvidence synthesisMuscle ContractionJournal of sport rehabilitation
researchProduct

Internal Fixation of Proximal Humeral Fractures: Current Concepts

2003

Fractures of the proximal humerus are an increasingly common type of injury. Mainly elderly patients with osteoporotic bone are affected. Whereas non-displaced and stable fractures are managed successfully with conservative treatment, there is no general agreement on the surgical strategy for displaced and unstable two- to four-part fractures. The clinical outcome is influenced by the fracture type and concomitant injury to the rotator cuff. Extensive surgical manipulation of the soft tissues, non-anatomic and/or unstable fixation as well as technical errors are important contributing factors to poor clinical results. Goals of surgical treatment are to restore anatomy, to achieve fixation t…

medicine.medical_specialtySports medicinebusiness.industrymedicine.medical_treatmentSoft tissueAvascular necrosismedicine.diseaseSurgerylaw.inventionIntramedullary rodFixation (surgical)medicine.anatomical_structurelawmedicineInternal fixationSurgeryRotator cuffHumerusbusinessEuropean Journal of Trauma
researchProduct

Association Between COL5a1, COL11a1, and COL11a2 Gene Variations and Rotator Cuff Tendinopathy in Young Athletes

2021

Objective Tendinopathy is a prevalent condition in young athletes and in older nonathletic people. Recent tendinopathy research has shown a growing interest in the role played by genetic factors, basically genes involved in collagen synthesis and regulation, in view of collagen disorganization typically present in tendon pathologies. Design A case-control, genotype-phenotype association study. Setting La Ribera Hospital, Valencia, Spain. Participants A group of 137 young athletes (49 with rotator cuff tendon pathology and 88 healthy counterparts) who played upper-limb-loading sports were clinically and ultrasound (US) assessed for rotator cuff tendinopathy were included. Intervention Geneti…

medicine.medical_specialtybiologyAthletesbusiness.industryPhysical Therapy Sports Therapy and RehabilitationSingle-nucleotide polymorphismmedicine.diseasebiology.organism_classificationTendonsymbols.namesakemedicine.anatomical_structureInternal medicineGenotypemedicinesymbolsOrthopedics and Sports MedicineRotator cuffTendinopathybusinessPathologicalFisher's exact testClinical Journal of Sport Medicine
researchProduct

Orthotope arterialisierte Lebertransplantation bei Ratten mit Stenttechnik der supra- und infrahepatischen v. cava

2003

The aim of this study was to establish a liver transplant model with a reduced warm ischemic period between cold preservation and completed anastomosis. Male brown Norway rats were used. A cuff was fixed in the portal vein, stents were inserted in the A. hepatica, the suprahepatic and infrahepatic v. cava and in the bile duct. After cross clamping of the recipient liver, another stent, occluded by a small pin, was introduced in the recipient suprahepatic v. cava. After ligation of this recipient suprahepatic caval stent the recipient liver was removed and the cold prepared donor liver was pushed forward along the pin and both suprahepatic stents of recipient and donor were connected. Then c…

medicine.medical_specialtybusiness.industryBile ductmedicine.medical_treatmentPortal veinStentAnastomosisSurgerymedicine.anatomical_structureCuffcardiovascular systemmedicineCold preservationcardiovascular diseasesLiving donor liver transplantationLigationbusiness
researchProduct

Bedeutung der Kalkdepot-elimination bei Tendinosis calcarea der Schulter

2000

Aim: To evaluate the effect of complete elimination of the calcific deposit on the clinical outcome in patients with a recalcitrant calcifying tendinitis of the shoulder. Patients and methods: 50 patients with a chronic calcifying tendinitis of the shoulder (Type Gartner I or II) underwent a single application of extracorporeal shock waves (3000 impulses, energy flux density 0.60mj/ mm 2 ). After one year 45 patients were evaluated radiologically and clinically. Results: Radiologically a complete absorption of the calcific deposit was observed in 21 patients (47%). In 9 patients there was no radiological change. The radiological success was closely related to the radiomorphology of the depo…

medicine.medical_specialtybusiness.industryRadiographymedicine.medical_treatmentLithotripsymedicine.diseaseExtracorporealSurgerymedicine.anatomical_structureTendinitisCalcifying tendinitisMedicineUpper limbOrthopedics and Sports MedicineSurgeryRotator cuffbusinessCalcificationZeitschrift für Orthopädie und ihre Grenzgebiete
researchProduct

Subglottic stenosis imitating the carina – a case report of airway mimicry

2021

Summary We present a case of awake tracheal intubation with flexible bronchoscopy which resulted in incorrect tracheal tube placement. The presence of a stenotic subglottic lesion with an appearance similar to the carina led to the tube being positioned with only the tip within the trachea whilst the cuff was located between the vocal cords. A capnography trace was identified before induction of anaesthesia; however, visual confirmation of the carina was undertaken in a rushed manner due to the patient becoming agitated. Once the incorrect tracheal tube placement was identified, the decision was made to wake the patient. Thereafter, a more experienced operator successfully performed awake t…

medicine.medical_specialtyfailed intubation: treatmentmedicine.medical_treatmentSubglottic stenosisSubglottic lesion610 MedizinEnergy Engineering and Power TechnologyCase ReportCase ReportsTracheal tube610 Medical sciencesmedicinedifficult airway algorithmCapnographymedicine.diagnostic_testbusiness.industryTracheal intubationpredictors of difficult intubationrespiratory systemmedicine.diseaseSurgeryFuel TechnologyCuffTube placementbusinessAirwayAnaesthesia Reports
researchProduct