Search results for "CURVE"
showing 10 items of 1693 documents
Discovery of a soft X-ray 8 mHz QPO from the accreting millisecond pulsar IGR J00291+5934
2016
In this paper, we report on the analysis of the peculiar X-ray variability displayed by the accreting millisecond X-ray pulsar IGR J00291+5934 in a 80 ks-long joint NuSTAR and XMM-Newton observation performed during the source outburst in 2015. The light curve of the source was characterized by a flaring-like behavior, with typical rise and decay time scales of ~120 s. The flares are accompanied by a remarkable spectral variability, with the X-ray emission being generally softer at the peak of the flares. A strong quasi periodic oscillation (QPO) is detected at ~8 mHz in the power spectrum of the source and clearly associated with the flaring-like behavior. This feature has the strongest po…
The size of juxtaluminal hypoechoic area in ultrasound images of asymptomatic carotid plaques predicts the occurrence of stroke
2013
Abstract OBJECTIVE: To test the hypothesis that the size of a juxtaluminal black (hypoechoic) area (JBA) in ultrasound images of asymptomatic carotid artery plaques predicts future ipsilateral ischemic stroke. METHODS: A JBA was defined as an area of pixels with a grayscale value 10 mm(2) (P 8 mm(2)) was still significant after adjusting for other plaque features known to be associated with increased risk, including stenosis, grayscale median, presence of discrete white areas without acoustic shadowing indicating neovascularization, plaque area, and history of contralateral TIA or stroke. Plaque area and grayscale median were not significant. Using the significant variables (stenosis, discr…
A new hybrid procedure for the definition of seismic vulnerability in Mediterranean cross-border urban areas
2016
Assessment of seismic vulnerability of urban areas provides fundamental information for activities of planning and management of emergencies. The main difficulty encountered when extending vulnerability evaluations to urban contexts is the definition of a framework of assessment appropriate for the specific characteristics of the site and providing reliable results with a reasonable duration of surveys and post-processing of data. The paper proposes a new procedure merging different typologies of information recognized on the territories investigated and for this reason called “hybrid.” Knowledge of historical events influencing urban evolution and analysis of recurrent building technologie…
Effects of dead time losses on terrestrial gamma ray flash measurements with the Burst and Transient Source Experiment
2010
[1] Measurements from the Burst and Transient Source Experiment (BATSE) instrument on the Compton Gamma Ray Observatory (CGRO) are the only ones where characteristics of single terrestrial gamma ray flashes (TGFs) have been obtained thus far. However, it has been reported that the measurements suffer from significant dead time losses which complicates the analysis and raises question about earlier BATSE studies. These losses are due to the high-intensity flux combined with limitations of the time resolution of the instrument. Since these losses will affect both the spectrum and the temporal distribution of the individual TGFs, results based on BATSE data need to be revisited, including our …
Une méthode rapide et simple pour l'estimation de la position de la courbe de dissociation de l'oxyhémoglobine
1989
The methods currently available for assessing the oxyhaemoglobin dissociation curve parameters are expensive, lengthy, require a large volume of blood, and the results obtained are modified by anaesthetic gases. The equipment required for the method described includes: a microtonometre, microcuvettes, 3 gas bottles containing different oxygen, carbon dioxide and nitrogen mixtures (4.5%, 5.6%, 89.9%; 3.5%, 5.6%, 90.9%; 2.5%, 5.6%, 91.9% respectively), a microxymetre, and a micropHmetre. The samples in the microcuvettes are incubated at 37 degrees C in a gas flow of 45 ml.min-1 from the bottles. SO2 is then read using the microxymetre. P50, i.e. PO2 at 50% saturation, is calculated, as well a…
HEp-2 intensity classification based on deep fine-tuning
2020
The classification of HEp-2 images, conducted through Indirect ImmunoFluorescence (IIF) gold standard method, in the positive / negative classes, is the first step in the diagnosis of autoimmune diseases. Since the test is often difficult to interpret, the research world has been looking for technological features for this problem. In recent years the methods of deep learning have overcome the other machine learning techniques in their effectiveness and robustness, and now they prevail in artificial intelligence studies. In this context, CNNs have played a significant role especially in the biomedical field. In this work we analysed the capabilities of CNN for fluorescence classification of…
Novel M. tuberculosis specific IL-2 ELISpot assay discriminates adult patients with active or latent tuberculosis
2018
Background Tuberculosis (TB) still is a major worldwide health problem, with 10.4 million new cases in 2016. Only 5–15% of people infected with M. tuberculosis develop TB disease while others remain latently infected (LTBI) during their lifetime. Thus, the absence of tests able to distinguish between latent infection and active tuberculosis is one of the major limits of currently available diagnostic tools. Methods A total of 215 patients were included in the study as active TB cases (n = 73), LTBI subjects (n = 88) and healthy persons (n = 54). Peripheral blood mononuclear cells (PBMCs) were isolated from each patient and the LIOSpot® TB anti-human IL-2 ELISpot assay was performed to test …
Effects of mixed reality head-mounted glasses during 90 minutes of mental and manual tasks on cognitive and physiological functions
2018
Background We evaluated the effects of a mixed reality (MR) head-mounted deviceon some cognitiveand physiological functions during 90 min tasks in an attempt to determine their safety for workers. Methods A total of 12 volunteers performed 90-min intellectual and manual tasks with and without MR glasses. Balance, Stroop, and memory tests were conducted before, during and after these tasks. Heart rate and electromyographic activity of some muscles were recorded. A survey was used to determine subjective fatigue, pain, or discomfort. Results Balance, heart rate, rate of perceived exertion, memory, and attention were unaffected by wearing MR glasses. Electromyographic activity increased with …
Experimental observations of upstream overdeepening
2005
The issue of morphodynamic influence in meandering streams is investigated through a series of laboratory experiments on curved and straight flumes. Both qualitative and quantitative observations confirm the suitability of the recent theoretical developments (Zolezzi & Seminara 2001) that indicate the occurrence of two distinct regimes of morphodynamic influence, depending on the value of the width ratio of the channel β. The threshold value βR separating the upstream from the downstream influence regimes coincides with the resonant value discovered by Blondeaux & Seminara (1985). Indeed it is observed that upstream influence may occur only in relatively wide channels, while narrower stream…
Historical Part—Calculus of Variations
2018
The calculus of variations is an old mathematical discipline and historically finds its origins in the introduction of the brachistochrone problem at the end of the 17th century by Johann Bernoulli to challenge his contemporaries to solve it. Here, we briefly introduce the reader to the main results.