ARC FAULT DETECTION EQUIPMENT AND METHOD USING LOW FREQUENCY HARMONIC CURRENT ANALYSIS

2012

An arc fault detection circuit includes a current sensing circuit coupled to a line conductor carrying a current. The current sensing circuit operates to sense current and output data indicative of the sensed current. A processing circuit implements a frequency transform algorithm to transform the output data to frequency data in a low frequency range and with a high spectral resolution where a minimum short time observation window is concerned. The processing circuit identifies an arc fault condition on the line conductor by identifying differences in said frequency data between at least two subsequent observation windows and identifying characteristics which exceed thresholds.

Settore ING-INF/07 - Misure Elettriche E Elettronichearc faults detection home protection photovoltaic systems electrical safety series arcs arc fault circuit interrupter (AFCI) harmonic analysis chirp-z transform (CZT)
researchProduct

Fabrication of CZTSe/CIGS Nanowire Arrays by One-Step Electrodeposition for Solar-Cell Application

2021

The paper reports some preliminary results concerning the manufacturing process of CuZnSnSe (CZTSe) and CuInGaSe (CIGS) nanowire arrays obtained by one-step electrodeposition for p-n junction fabrication. CZTSe nanowires were obtained through electrodeposition in a polycarbonate membrane by applying a rectangular pulsed current, while their morphology was optimized by appropriately setting the potential and the electrolyte composition. The electrochemical parameters, including pH and composition of the solution, were optimized to obtain a mechanically stable array of nanowires. The samples were characterized by scanning electron microscopy, Raman spectroscopy, and energy-dispersion spectros…

Technologynanowires solar cellsFabricationMaterials scienceScanning electron microscope020209 energytemplate electrodepositionNanowireCZTSe solar cell02 engineering and technologyArticlelaw.inventionsymbols.namesakelawSettore ING-IND/17 - Impianti Industriali MeccaniciSolar cellnanostructures0202 electrical engineering electronic engineering information engineeringGeneral Materials ScienceThin filmMicroscopyQC120-168.85business.industryTCZTSe solar cell nanostructures nanowires solar cells template electrodepositionQH201-278.5Engineering (General). Civil engineering (General)021001 nanoscience & nanotechnologyCopper indium gallium selenide solar cellsTK1-9971Settore ING-IND/23 - Chimica Fisica ApplicataDescriptive and experimental mechanicssymbolsOptoelectronicsElectrical engineering. Electronics. Nuclear engineeringTA1-20400210 nano-technologybusinessRaman spectroscopyChemical bath depositionMaterials
researchProduct

Roads, travelling and communication in the Polish – Lithuanian Commonwealth in the 18th century. Russian and West European visitors’ perspective

2020

W artykule przedstawiony został stan techniczny dróg lądowych i rzecznych, mostów, grobli oraz pozostałej infrastruktury komunikacyjnej w Polsce na podstawie relacji podróżników z zagranicy, w tym Rosjan. Stan oraz jakość lądowych i rzecznych środków transportu był oceniany przez cudzoziemców bardzo nisko, podobnie jak jakość usług oferowanych w przydrożnych karczmach w Polsce i na Litwie. W rezultacie podróżowanie w XVIII w. po Rzeczypospolitej mogło stanowić interesujące doświadczenie. Tak goście z Rosji, jak i z krajów zachodniej Europy natrafiali na wiele przeszkód w trakcie podróży, postrzegając przy tym kraj jako pełen paradoksów. Fatalny stan dróg, przerażające swoim standardem karcz…

The Polish-Lithuanian CommonwealthTravellingTravelsCommunicationThe Eighteenth CenturykomunikacjapocztaRoadspodróżowaniePostRussian visitors in Poland and Lithuania; visitors from countries of western Europe in Poland and LithuaniaRosjanie w Polsce i na Litwie; przybysze z zachodniej Europy w Polsce i na Litwiewiek osiemnasty; Rzeczpospolita Obojga NarodówpodróżnicydrogiIn Gremium. Studia nad Historią, Kulturą i Polityką
researchProduct

Ballistic Deficit Pulse Processing in Cadmium-Zinc-Telluride Pixel Detectors for High-Flux X-ray Measurements.

2022

High-flux X-ray measurements with high-energy resolution and high throughput require the mitigation of pile-up and dead time effects. The reduction of the time width of the shaped pulses is a key approach, taking into account the distortions from the ballistic deficit, non-linearity, and time instabilities. In this work, we will present the performance of cadmium–zinc–telluride (CdZnTe or CZT) pixel detectors equipped with digital shapers faster than the preamplifier peaking times (ballistic deficit pulse processing). The effects on energy resolution, throughput, energy-linearity, time stability, charge sharing, and pile-up are shown. The results highlight the absence of time instabilities …

X-ray and gamma ray detectorsPhysics::Instrumentation and DetectorsX-RaysBiochemistrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Atomic and Molecular Physics and OpticsCdTe detectorsAnalytical ChemistryZincElectrical and Electronic EngineeringTelluriumInstrumentationCZT detectors; CdTe detectors; X-ray and gamma ray detectorsCZT detectorsCadmiumSensors (Basel, Switzerland)
researchProduct

Window-Based Energy Selecting X-ray Imaging and Charge Sharing in Cadmium Zinc Telluride Linear Array Detectors for Contaminant Detection

2023

The spectroscopic and imaging performance of energy-resolved photon counting detectors, based on new sub-millimetre boron oxide encapsulated vertical Bridgman cadmium zinc telluride linear arrays, are presented in this work. The activities are in the framework of the AVATAR X project, planning the development of X-ray scanners for contaminant detection in food industry. The detectors, characterized by high spatial (250 µm) and energy (<3 keV) resolution, allow spectral X-ray imaging with interesting image quality improvements. The effects of charge sharing and energy-resolved techniques on contrast-to-noise ratio (CNR) enhancements are investigated. The benefits of a new energy-resolved …

energy-resolved X-ray imagingcharge sharingsemiconductor pixel detectorsX-ray detectorsElectrical and Electronic EngineeringCZT detectors; charge sharing; semiconductor pixel detectors; X-ray detectors; energy-resolved X-ray imaging; contaminant detectionBiochemistryInstrumentationAtomic and Molecular Physics and Opticscontaminant detectionSettore FIS/03 - Fisica Della MateriaAnalytical ChemistryCZT detectors
researchProduct

High Bias Voltage CZT Detectors for High-flux Measurements

2017

In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm(2)) and a central anode (2 x 2 mm(2)) surrounded by a guard ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm(2) at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWIEM at 59.5…

radiation detectorRadiology Nuclear Medicine and ImagingMaterials sciencePreamplifier02 engineering and technology01 natural scienceslaw.inventionlawpixel0103 physical sciencesInstrumentationNuclear and High Energy Physic010308 nuclear & particles physicsbusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleElectrical engineeringBiasing021001 nanoscience & nanotechnologyPhoton countingCathodeSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)AnodeElectronic Optical and Magnetic MaterialsCZTFull width at half maximumHigh Fluxhigh bias voltageOptoelectronicssemiconductor detector0210 nano-technologybusinessVoltage
researchProduct

Microscale X-ray mapping of CZT arrays: Spatial dependence of amplitude, shape and multiplicity of detector pulses

2018

In this work, we present the results of a microscale X-ray mapping of a 2 mm thick CZT pixel detector, with pixel pitches of 500 μm and 250 μm, using collimated synchrotron X-ray sources at the Diamond Light source (U. K.). The detector is dc coupled to a fast and low noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to perform online fast pulse shape and height analysis (PSHA), with low dead time and reasonable energy resolution at both low and high fluxes. The detector allows high bias voltage operation (> 5000 V/cm) and good energy resolution at room temperature (5.3 %, 2.3 % and 2.1 % FWHM at 22.1, 59…

radiation detectorRadiology Nuclear Medicine and ImagingNuclear and High Energy PhysicsMaterials sciencePreamplifier01 natural sciencesCollimated light030218 nuclear medicine & medical imagingCharge sharinglaw.invention03 medical and health sciences0302 clinical medicineOpticslaw0103 physical scienceshigh fluxmappingInstrumentation010308 nuclear & particles physicsbusiness.industryASICDetectorBiasingDead timeSynchrotronSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CZTFull width at half maximumsinchrotron radiationbusiness
researchProduct

High-Resolution 3-D CZT Drift Strip Detectors for Prompt Gamma Ray and Neutron Detection in BNCT

2021

Spectroscopic imagers based on high-Z and wide-bandgap compound semiconductor detectors are widely proposed for the detection of prompt gamma rays in boron neutron capture therapy (BNCT). BNCT is a therapy based on the neutron capture reaction 10B (n,α)7Li. To perform a real-time monitoring of the spatial distribution of 10B during the treatments, the detection of the prompt gamma rays (478 keV), produced by the 7Li recoil nuclei, can be helpful. In this work, we presented the potentialities of new high-resolution CZT drift strip detectors, recently developed by our group, for BNCT measurements. The detectors, exploiting the analysis of the collected-induced charge pulses from anodes, catho…

semiconductor detectorsboron neutron capture therapySettore FIS/01 - Fisica SperimentaleCZT detectorSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Characterization of a CZT focal plane small prototype for hard X-ray telescope

2005

The promise of good energy and spatial resolution coupled with high efficiency and room temperature operation has fuelled a large international effort to develop cadmium zinc telluride (CZT) for hard X-ray applications. We are involved on the development of a hard X-ray telescope based on multilayer optics and focal plane detector operative in the 10-80 keV energy range. This telescope requires a high efficiency focal plane providing both fine spatial resolution and spectroscopy with a compact and robust design. This paper reports preliminary results on the characterization both in spectroscopic and spatial response of two small pixellated CZT detectors (10times10times1 mm3 and 10times10tim…

spectroscopyNuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsX-ray telescopeParticle detectorlaw.inventionTelescopechemistry.chemical_compoundOpticslawElectronicsElectrical and Electronic EngineeringImage resolutionPhysicsPixelbusiness.industryAstrophysics::Instrumentation and Methods for AstrophysicsCadmium zinc tellurideCZTCardinal pointNuclear Energy and Engineeringchemistrypixel detectorfocal planehard X-rayOptoelectronicsbusinessIEEE Transactions on Nuclear Science