Search results for "Cable"

showing 10 items of 329 documents

Pulsed Electro-Acoustic Method for specimens and cables employed in HVDC systems: Some feasibility considerations

2018

Recent experiments on the use of the PEA method for testing dielectric materials in specimens and comparison with a detailed model provide an insight of the phenomenon and suggest the need of adopting similar models also for cables. What is said is even more important considering the possible future adoption of the PEA methodology to test DC cables for Pre-Qualification and Type Tests. The use of an accurate model of the PEA cell used for testing specimens and related experiments prove that the thickness of the different parts composing the PEA setup is a basic element for providing accurate charge reading and interpretation of the phenomenon. Both simulation and experimental results, carri…

010302 applied physicsControl and OptimizationComputer science020209 energySample (material)Issues in PEA measurementMechanical engineeringEnergy Engineering and Power Technology02 engineering and technologyAcoustic wave01 natural sciencesSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaSettore ING-IND/31 - ElettrotecnicaPulsed Electro-Acoustic methodComputer Networks and Communication0103 physical sciencesReflection phenomenon0202 electrical engineering electronic engineering information engineeringDC cableCharge accumulation
researchProduct

Space charge accumulation in undersea HVDC cables as function of heat exchange conditions at the boundaries – water-air interface

2020

Transmission lines with undersea HVDC cables are an interesting technological solution for the supply of electrical energy to islands. The accumulation of space charge inside the dielectric layer of a HVDC cable is one of the most important element to consider in its design and during operation. The formation of space charge is due to various factors including the high dependence on the temperature of the electrical conductivity of the insulation and the establishment of a thermal gradient under load conditions. This research is focused on the space charge accumulation phenomenon around a section of a HVDC cable half dipped in water and half in air. Due to the high difference in thermal con…

010302 applied physicsMaterials science020209 energyElectric potential energy02 engineering and technologyMechanicsThermal conduction01 natural sciencesSpace chargeHVDC cables space charge sustainable islandsSettore ING-IND/31 - ElettrotecnicaTemperature gradientThermal conductivityElectric power transmissionElectric field0103 physical sciencesHeat exchanger0202 electrical engineering electronic engineering information engineering2020 IEEE 20th Mediterranean Electrotechnical Conference ( MELECON)
researchProduct

Partial discharge detection and localization along medium voltage cables

2017

In the last years different partial discharge (PD) measuring techniques have been developed because PD diagnostic is the most widely tool to evaluate the insulation condition of a power cable. Recently non-conventional methods and sensors have been used in order to reach improved results in PD measurements. The purpose of this work is to perform measurements that allow to study the variation of pulses when they travel along a MV cable and to locate the pulse source through the time arrival difference of the pulses obtained from two sensors installed separately.

010302 applied physicsMaterials sciencebusiness.industryAcousticsElectronic Optical and Magnetic Material01 natural sciencesPulse (physics)PD measurementSettore ING-IND/31 - Elettrotecnica0103 physical sciencesPartial dischargeWirelessPower cablePD localizationPartial DischargeElectrical and Electronic EngineeringbusinessVoltage
researchProduct

Critical issues in the PD testing methodology for XLPE-insulated MV cables: An experimental case

2017

This paper describes some critical issues arising during the partial discharge (PD) testing of a 500m delivery length of an XLPE-insulated MV cable. At first, conventional PD measurements were performed on the whole length by using a standard acquisition system; PDs activity was detected, but the system allowed the operator to localize the PDs only on a length of 70 m. A visual inspection of this section highlighted the presence of an excoriation in the outer sheet. Aiming at a more accurate pin-pointing of the defect, more measurements were carried out in the proximity of the outer defect using a portable PD detection system. These measurements showed PDs activity, whose source was located…

010302 applied physicsOperator (computer programming)Cables Cable testing MV cables Partial Discharges Partial Discharge Measurements Partial Discharge testing PD detection Wireless PD detection XLPE-insulated cablesSection (archaeology)Computer scienceAcoustics0103 physical sciencesExcoriationPartial discharge01 natural sciences2017 IEEE Conference on Electrical Insulation and Dielectric Phenomenon (CEIDP)
researchProduct

Investigation on partial discharges in HVDC cables after polarity reversal events

2020

Due to the accumulation of space charge inside the insulating layer of HVDC cables, the electric field under load conditions may be altered compared to what is established in HVAC cables. For example, a high thermal gradient leads to the inversion of the electric field pattern until the maximum value is reached in proximity of the dielectric-semicon interfaces. These maximum values can be further increased due to transient overvoltages and polarity reversal events until reaching electric field values higher than the rated ones. The main goal of this research is to investigate the possibility that, during these transient phenomena, conditions are created that favor the occurrence of partial …

010302 applied physicsPolarity reversalMaterials science0211 other engineering and technologies02 engineering and technologyMechanics01 natural sciencesSpace chargeHVDC cable Polarity reversal HVDC joint Space chargeTemperature gradientSettore ING-IND/31 - ElettrotecnicaElectric field0103 physical sciencesPartial dischargeThermal021108 energyTransient (oscillation)Energy (signal processing)
researchProduct

Polarity reversal in HVDC joints - The effect of the axial thermal conduction

2020

It has been shown that the establishment of a thermal gradient over the radius of HVDC cables involves the accumulation of space charge within the dielectric layer. High thermal gradients over the insulation thickness of loaded cables can lead to the inversion of the radial electric field pattern. In this scenarios, transient overvoltages and polarity reversal can lead to local and transitory peaks of electric field. Since the temperature distribution plays an important role in reaching critical values of the electric field, it has been considered interesting to have a more in-depth view of the thermal behavior of HVDC systems close the discontinuities of the geometry along the cable axis. …

010302 applied physicsPolarity reversalPolarity reversalMaterials science020209 energy02 engineering and technologyMechanicsThermal conduction01 natural sciencesSpace chargeSpace chargeTemperature gradientSettore ING-IND/31 - ElettrotecnicaThermal conductivityElectric field0103 physical sciencesHeat transferHVDC joint0202 electrical engineering electronic engineering information engineeringHVDC cableVoltage
researchProduct

Review of the PEA Method for Space Charge Measurements on HVDC Cables and Mini-Cables

2019

This review takes into account articles and standards published in recent years concerning the application of the Pulsed Electro Acoustic (PEA) method for space charge measurement on High Voltage Direct Current (HVDC) cables and mini-cables. Since the 80s, the PEA method has been implemented for space charge measurements on flat specimens in order to investigate space charge phenomena and to evaluate the ageing of dielectrics. In recent years, this technique has been adapted to cylindrical geometry. Several studies and experiments have been carried out on the use of the PEA method for full size cables and HVDC cable models. The experiments have been conducted using different arrangements of…

010302 applied physicspulsed Electroacoustic technique (PEA)Cylindrical geometryControl and Optimizationlcsh:TRenewable Energy Sustainability and the EnvironmentComputer science020209 energyEnergy Engineering and Power TechnologyMechanical engineering02 engineering and technologylcsh:Technology01 natural sciencesSpace chargeHVDC cablesSpace chargeSettore ING-IND/31 - ElettrotecnicaReliability (semiconductor)0103 physical sciences0202 electrical engineering electronic engineering information engineeringHigh-voltage direct currentElectrical and Electronic EngineeringEngineering (miscellaneous)Energy (miscellaneous)
researchProduct

Relations between Air Quality and Covid-19 Lockdown Measures in Valencia, Spain

2021

The set of measures to contain the diffusion of COVID-19 instituted by the European governments gave an unparalleled opportunity to improve our understanding of the transport and industrial sectors’ contribution to urban air pollution. The purpose of this study was to assess the impacts of the lockdown measures on air quality and pollutant emissions in Valencia, Spain. For this reason, we determined if there was a significant difference in the concentration levels of different particulate matter (PM) sizes, PM10, PM2.5, and NOx, NO2, NO, and O3, between the period of restrictions in 2020 and the same period in 2019. Our findings indicated that PM pollutant levels during the lockdown period…

010504 meteorology & atmospheric sciencesCoronavirus disease 2019 (COVID-19)Pollutant emissionsHealth Toxicology and Mutagenesisair pollutionAir pollutionlcsh:Medicine010501 environmental sciencesmedicine.disease_cause01 natural sciencesArticleToxicologylockdownmedicineHumansValenciaAir quality index0105 earth and related environmental sciencesPollutantbiologyparticulate matter (pm)Significant differencelcsh:RPublic Health Environmental and Occupational HealthParticulatesbiology.organism_classificationnitrogen oxidesozoneSpainCommunicable Disease ControlEnvironmental scienceParticulate MatterCovid-19Environmental MonitoringInternational Journal of Environmental Research and Public Health
researchProduct

Recreational noise pollution of traditional festivals reduces the juvenile productivity of an avian urban bioindicator.

2021

Noise is a pollutant of emergent concern for ecologists and conservation biologists. Recreational noise pollution, especially unpredictable and intermittent sounds, and its effects on wildlife and biodiversity have been poorly studied. Researchers have paid very little attention to the effect of noisy traditional festivals (fireworks and powder-guns). This study aimed to explore the effect of these recreational activities on the juvenile productivity of an urban avian bioindicator: the house sparrow. We studied five pairs of localities in the Valencia Region (E Spain) with noisy traditional festivals. Each pair was composed of one locality with festivals during the breeding season and the c…

010504 meteorology & atmospheric sciencesHealth Toxicology and MutagenesisWildlifeBiodiversity010501 environmental sciencesToxicology01 natural sciencesbiology.animalSeasonal breederJuvenileAnimalsHumansHouse sparrowRecreation0105 earth and related environmental sciencesHolidaysSparrowbiologyEnvironmental BiomarkersSARS-CoV-2FireworksCOVID-19General MedicineEcologíaCensusPollutionFisheryPlant BreedingGeographyProductivity (ecology)Communicable Disease ControlRecreational noiseNoiseSparrowsEnvironmental pollution (Barking, Essex : 1987)
researchProduct

Benefits of immune protection versus immunopathology costs: a synthesis from cytokine KO models.

2017

5 pages; International audience; The inflammatory response can produce damage to host tissues and in several infectious diseases the most severe symptoms are due to immunopathology rather than a direct effect of pathogen multiplication. One hypothesis for the persistence of inflammatory damage posits that the benefits of protection towards infection outweigh the costs. We used data on knocked-out (KO) cytokine models [and the corresponding wild-type (WT) controls] to test this hypothesis. We computed differences in pathogen load and host survival between WT and KO and divided them by the WT values. Using this ratio provides an internal control for variation in pathogen species, host strain,…

0106 biological sciences0301 basic medicineMicrobiology (medical)medicine.medical_treatmentVirulenceInflammationImmunopathologyBiologyCommunicable Diseases010603 evolutionary biology01 natural sciencesMicrobiologyPersistence (computer science)Gene Knockout Techniques03 medical and health sciencesImmunopathologyGeneticsmedicine[ SDV.EE.IEO ] Life Sciences [q-bio]/Ecology environment/SymbiosisAnimalsHumans[ SDV.IMM ] Life Sciences [q-bio]/ImmunologyMolecular BiologyPathogenCytokineEcology Evolution Behavior and SystematicsInflammationVirulenceHost (biology)Immune protectionHost survivalComputational BiologyPathogen loadDisease Models Animal030104 developmental biologyInfectious DiseasesCytokineHost-Pathogen InteractionsImmunologyCytokinesmedicine.symptom
researchProduct