Efficient modeling of a combined overhead cable line for grounding-system analysis
2008
Simple compact models for combined overhead-cable lines supplying a substation are presented as an extension of a previous paper for grounding system analysis. The overhead line section can be equipped with uniform or combined ground wires, whereas the cable line section can consist of coated metal sheathed cables, with/without intermediate grounding, or uncoated metal sheathed cables in continuous contact with the earth. Besides the calculation of the earth current at the faulted substation, the proposed modeling method allows the evaluation of the leakage current at the transition station, where cables are connected to the overhead line, as well as at critical overhead line towers. In thi…
Overcoming synchronization issues in wireless technology Partial Discharge measurement
2016
In this paper, several aspects of the fundamentals of wireless Partial Discharge (PD) measurements are first discussed. Then, the relevance of the problem of voltage synchronization in PD wireless diagnosis is outlined. When portable instruments are used for PD detection, the main issue is the voltage measurement at the site where the PD detection is carried out. When such analysis is carried out over shielded cables, the AC (50/60 Hz) voltage reference signal is not easily detectable, while one of the basic parameters for PD diagnosis, the displacement of the inception voltage of the PD as compared to the reference voltage, is not available. Even if highperformance sensors are readily avai…
A Simple Method for Evaluating Ground-Fault Current Transfer at the Transition Station of a Combined Overhead-Cable Line
2008
When a substation is fed by a combined overhead-cable transmission line, a significant part of the ground fault current flows through cable sheaths and is discharged into the soil at the transition station where cables are connected to the overhead line. Such a phenomenon, known as ldquofault application transfer,rdquo may result in high ground potentials at the transition station which may cause shocks and equipment damage. The scope of this paper is to present new analytic formulas which can be used for the direct calculation of the fault current transferred at the transition station and its ground potential rise as well as the substation earth current. The proposed formulas allow evaluat…
A Mixed Approach for Determination of Initial Cable Forces in Cable-Stayed Bridges and the Parameters Variability
2015
The determination of initial cable forces in cable-stayed bridges is an important first step in design and analysis of the structure under external loads. Adjustments of stay forces are often required during construction in order to assure the requested behaviour of the bridge in terms of final geometrical configuration and internal force distribution. An accurate assessment of the stay tensioning system allows designers to obtain a good result at the end of construction, by considering the parameters involved as deterministic quantities, assuring the observance of the execution tolerances during works. Actual loads and their variations need instead a stochastic approach which can give usef…
Ground-Fault Current Transfer at the Transition Station of a Combined Overhead-Cable Line. A Parametric Analysis
2007
When a substation is fed by a combined overhead-cable transmission line, a significant part of the ground fault current flows through the grounded cable sheaths and discharges into the earth at the transition station, where cables are connected to the overhead line. If the transition station is a dead-end steel pole structure, the local ground electrode, small and of high resistance, could be inadequate to maintain the ground potential rise within safety limits in case of a fault to ground at the receiving end substation. Based on a circuit model approach, the paper presents a parametric analysis of the fault current distribution between the faulted substation and the transition station, ta…
A mobile robot for vigilance tasks improved with a new robust and low cost communications system immune to attacks with EMI noise
2006
This work pretends to develop a robot for vigilance tasks that are able to tolerate diverse kinds of attacks and be able to operate in environments with elevated electromagnetic noise, being even immune to sabotage provoked by means of high electromagnetic fields. A new CAN based communications system that interconnects the different devices that compose the mobile robot has been developed to achieve this goal. The system is based on a shielded communications hub, that interconnects diverse nodes by means of CAN. On the other hand, the point to point communication between each node and the hub is carried out by means of economic optical fiber. With this approach all robot devices are connec…
Monte Carlo simulation for the response analysis of long-span suspended cables under wind loads
2004
This paper presents a time-domain approach for analyzing nonlinear random vibrations of long-span suspended cables under transversal wind. A consistent continuous model of the cable, fully accounting for geometrical nonlinearities inherent in cable behavior, is adopted. The effects of spatial correlation are properly included by modeling wind velocity fluctuation as a random function of time and of a single spatial variable ranging over cable span, namely as a one-variate bi-dimensional (1V-2D) random field. Within the context of a Galerkin`s discretization of the equations governing cable motion, a very efficient Monte Carlo-based technique for second-order analysis of the response is prop…
Test bench for coupling and shielding magnetic field
2016
This paper describes a test bench for training purposes, which uses a magnetic field generator to couple this magnetic field to a victim circuit. It can be very useful to test for magnetic susceptibility as well. The magnetic field generator consists of a board, which generates a variable current that flows into a printed circuit board with spiral tracks (noise generator). The victim circuit consists of a coaxial cable concentric with the spiral tracks and its generated magnetic field. The coaxial cable is part of a circuit which conducts a signal produced by a signal generator and a resistive load. In the paper three cases are studied. First, the transmitted signal from the signal generato…
Effects of double ground faults in Wind Farms collector cables
2015
Medium Voltage collector cables of Wind Farms have metal shields connected to the grounding systems of the towers and of the connection station. Thanks to this bonding, when a ground fault occurs, the fault current splits itself among all the grounding systems of the wind farm, this causing a reduction of the ground potential rise at the fault location. Nevertheless, in presence of double ground faults, very high ground potential rises occur at the two fault locations and safety against electric shock is not always assured. In order to study this issue, the paper presents a model for simulating in a simple way the effects of double ground faults occurring in Medium Voltage collectors of ext…
A statistic approach of cables ageing in MV lines on thermal and electrical combined stress
2006
The paper introduces a methodology that through a probabilistic characterisation of load for MV network, and implementing a life model for combined electric and thermal stresses, simulates the process of ageing of the insulating materials evaluating the expected life time of the cable. Such evaluation is necessary to the possibility of assuming less restrictive thermal overloading limits on electrical cables, with the consequential increase on reserve that cables could offer. A numerical example is reported to better explain the methodology