Search results for "Caliber"
showing 8 items of 8 documents
The effect of cigar smoking on the lingual microcirculation
2005
The aim of this study was to analyze the lingual microcirculation in vivo and to evaluate the effects on it of cigar smoking, using computerized videocapillaroscopy. Twenty-five healthy nonsmokers and 25 healthy smokers were examined. For each subject we evaluated the visibility, course, tortuosity, and any images characteristic of capillary loops, as well as the possible presence of microhemorrhages, the average caliber of the capillary loops, and the number of capillary loops visible per square millimeter. The investigation of the lingual mucosa revealed capillary loops with a course parallel to the surface. In smokers, capillary loops had a smaller caliber (P < 0.001) and there was a hig…
Caliber-persistent Artery: A Case Report
2019
ABSTRACT The caliber-persistent labial artery (CPLA) is a vascular anomaly in which a main branch of the artery penetrates the submucosal area of the lip without loss of caliber. It commonly presents as an elevated soft tissue mass and is often pulsatile on manual palpation. Clinical suspicion is important, given the risk of bleeding, either from slight trauma or accidentally if lack of awareness leads to excision of the lesion owing to an incorrect diagnosis. CPLA should be considered in the differential diagnosis of any lesion affecting the lip, especially to differentiate from mucocele or squamous cell carcinoma. This particular case of CPLA in the upper lip of a girl presents a both unu…
Comparative analysis of numerical and experimental data of orthodontic mini-implants
2011
The purpose of this study was to compare numerical simulation data derived from finite element analysis (FEA) to experimental data on mini-implant loading. Nine finite element (FE) models of mini-implants and surrounding bone were derived from corresponding experimental specimens. The animal bone in the experiment consisted of bovine rib. The experimental groups were based on implant type, length, diameter, and angle of insertion. One experimental specimen was randomly selected from each group and was digitized in a microCT scanner. The FE models consisted of bone pieces containing Aarhus mini-implants with dimensions 1.5 × 7 mm and 1.5 × 9 mm or LOMAS mini-implants (dimensions 1.5 × 7 mm, …
Changes of the ratio between myelin thickness and axon diameter in the human developing sural nerve
1978
Axon caliber and myelin sheath thickness of individual nerve fibers were evaluated in the developing human sural nerve using three different methods of measurement: 1. ocular micrometer evaluation of large fibers, 2. photographic enlargements for evaluating large numbers of nerve fibers of all sizes, and 3. electron microscopic enlargements for more precise measurements in selected nerves. The average axonal diameter doubles from 5 months gestation to about 5 years of age. Large fiber group axons increase, during the same period, by a factor of 3--3.5 with a slight decrease thereafter. The myelin thickness increases more slowly, but continuously, between 5 months gestation until the age of …
Metal pins fired from unmodified blank cartridge guns and very small calibre weapons - technical and wound ballistic aspects
1998
Blank cartridge guns are generally regarded as being harmless and are not considered to be firearms in most countries. A comparison of the legal situations in Germany and Austria concerning weapons is given. There have been several reports of serious injuries and even fatalities due to these weapons. Ballistic experiments show that even unmodified blank cartridge guns and very small calibre weapons can fire wire nails and can inflict potentially fatal injuries even at distances of 50 cm. Two serious injuries inflicted by metal pins fired from a blank cartridge gun and a very small calibre weapon are reported. These cases suggest that such weapons should also be considered handguns in the le…
HEXCALIBER TEST SECTION. Preliminary thermo-mechanical analysis
2007
ALTERED RATIO BETWEEN AXON CALIBER AND MYELIN THICKNESS IN SURAL NERVES OF CHILDREN
1978
ABSTRACT Maturation of myelin sheaths in normal sural nerves of children proceeds more slowly than axon growth. This asynchronous development of axons and myelin sheaths results in a statistically significant change of the ratio between axon caliber and myelin thickness during normal development. Therefore, myelin thickness of individual nerve fibers must be related to the size of the axons as well as to the age of the individuals studied. Abnormalities of the relationship between myelin thickness and axon diameter (primary hypomyelination of large, or small, or all fibers) were clearly identified in cases with metachromatic leukodystrophy, KRABBE's, DEJERINE-SOTTAS’, COCKAYNE'S and SANFILI…
Relationship between tree water status and physiology, yield, and fruit quality in the table olive (Olea europaea sativa L.) cultivar ‘Nocellara del …
2012
Although the olive (Olea europaea sativa l.) is considered a xerophytic species, long periods of water stress and high temperatures during summer months can greatly affect plant physiology and productivity. In recent years, the use of plant-based water status indicators have become popular in the study of plant-water relationships and in the design of irrigation programs, particularly midday stem water potential (ψstem). The current trend in the irrigation of olive trees is in the development of Deficit Irrigation (DI) systems whereby the water is applied at a rate which is lower than evapotranspiration needs, resulting in only very small reductions in yield. Rather than working towards min…