Search results for "Calibration"
showing 10 items of 890 documents
Temperature effects on the performances of the ATHENA X-IFU thermal filters
2016
The X-Ray Integral Field Unit (X-IFU) detector on-board ATHENA is an array of TES micro-calorimeters that will operate at ~50 mK. In the current investigated design, five thermal filters (TF) will be mounted on the cryostat shields to attenuate IR radiative load and avoid energy resolution degradation due to photon shot noise. Each filter consists of a thin polyimide film (~50 nm thick) coated with aluminum (~30 nm thick). Since the TF operate at different temperatures in the range 0.05-300 K, it is relevant to study how temperature affects their mechanical/optical performances (e.g. near edge absorption fine structures of the atomic elements in the filter material). Such results are crucia…
Yeast cultures with UCP1 uncoupling activity as a heating device
2009
7 páginas, 5 figuras, 3 tablas -- PAGS nros. 300-306
Astronomical calibration of the Valanginian and the Hauterivian stages (lower cretaceous) : paleoclimatic and paleooceanographic implications
2013
Orbital floating time scales are proposed for the Valanginian Stage and part of the Hauterivian Stage (Early Cretaceous). These are based on the identification of the eccentricity cycles from spectral analyses performed on high-resolution climatic proxies measured on hemipelagic marl-limestone alternations. Five reference sections were analysed in the Vocontian Basin (SE France), spanning the entire Valanginian. A duration of 5,08 myr is proposed for the Valanginian Stage from the identification of the 405-kyr eccentricity cycle. The time frame proposed, combined with available radiometric ages, shows that the mid-Valanginian 13C positive excursion (namely the Weissert Event) occurs prior …
Ab initio determination of the ionization potentials of DNA and RNA nucleobases
2006
Quantum chemical high level ab initio coupled-cluster and multiconfigurational perturbation methods have been used to compute vertical and adiabatic ionization potentials of the five canonical DNA and RNA nucleobases: uracil, thymine, cytosine, adenine, and guanine. Several states of their cations have been also calculated. The present results represent a systematic compendium of these magnitudes, establishing theoretical reference values at a level not reported before, calibrating computational strategies, and guiding the assignment of the features in the experimental photoelectron spectra. Daniel.Roca@uv.es Mercedes.Rubio@uv.es Manuela.Merchan@uv.es Luis.Serrano@uv.es
Development of a real-time PCR assay for detection and quantification of enterotoxigenic members of Bacillus cereus group in food samples
2009
A highly sensitive real-time PCR (qPCR) procedure, targeting the phosphatidylcholine-specific phospholipase C gene (pc-plc), was developed for specific detection and quantification of strains belonging to Bacillus cereus group. The target region was selected based on the enterotoxigenic profiles of 75 Bacillus strains. The inclusivity and exclusivity of the RTi-PCR assay were assessed with 59 isolates of the B. cereus group, 16 other Bacillus spp., and 4 non-Bacillus strains. The assay was also used to construct calibration curves for different food matrices, and it had a wide quantification range of 6 log units using both serial dilutions of purified DNA and calibrated cell suspensions of …
Observations of Forbush Decreases of cosmic ray electrons and positrons with the Dark Matter Particle Explorer
2021
The Forbush Decrease (FD) represents the rapid decrease of the intensities of charged particles accompanied with the coronal mass ejections (CMEs) or high-speed streams from coronal holes. It has been mainly explored with ground-based neutron monitors network which indirectly measure the integrated intensities of all species of cosmic rays by counting secondary neutrons produced from interaction between atmosphere atoms and cosmic rays. The space-based experiments can resolve the species of particles but the energy ranges are limited by the relative small acceptances except for the most abundant particles like protons and helium. Therefore, the FD of cosmic ray electrons and positrons have …
Controlling false match rates in record linkage using extreme value theory
2011
AbstractCleansing data from synonyms and homonyms is a relevant task in fields where high quality of data is crucial, for example in disease registries and medical research networks. Record linkage provides methods for minimizing synonym and homonym errors thereby improving data quality. We focus our attention to the case of homonym errors (in the following denoted as ‘false matches’), in which records belonging to different entities are wrongly classified as equal. Synonym errors (‘false non-matches’) occur when a single entity maps to multiple records in the linkage result. They are not considered in this study because in our application domain they are not as crucial as false matches. Fa…
Sun Induced Fluorescence Calibration and Validation for Field Phenotyping
2018
Reliable measurements of Sun Induced Fluorescence (SIF) require a good instrument characterization as well as a complex processing chain. In this paper, we summarize the state of the art SIF retrieval methods and measurements platforms for field phenotyping. Furthermore, we use HyScreen, hyperspectral-imaging system for top of canopy measurements of SIF, as an example of the instrument requirements, data process, and data validation needed to obtain reliable measurements of SIF.
Industrial Environment Mapping Using Distributed Static 3D Sensor Nodes
2018
This paper presents a system architecture for mapping and real-time monitoring of a relatively large industrial robotic environment of size 10 m × 15 m × 5 m. Six sensor nodes with embedded computing power and local processing of the 3D point clouds are placed close to the ceiling. The system architecture and data processing is based on the Robot Operating System (ROS) and the Point Cloud Library (PCL). The 3D sensors used are the Microsoft Kinect for Xbox One and point cloud data is collected at 20 Hz. A new manual calibration procedure is developed using reflective planes. The specified range of the used sensor is 0.8 m to 4.2 m, while depth data up to 9 m is used in this paper. Despite t…
Determination of quality parameters of beers by the use of attenuated total reflectance-Fourier transform infrared spectroscopy
2005
Abstract The estimation of important quality parameters of beers, such as original and real extracts and alcohol content, has been evaluated by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) using a partial least square (PLS) calibration approach. Two sample populations, one consisting of 24 samples and other of 21 samples, obtained from the Spanish market and covering different types of beer were used. The first set was used for building and validating the model, whereas the second, measured 6 months after, was used for evaluating its robustness. The spectral range and the size of the calibration set and its suitability for building the PLS model have been …