Determination of edible oil parameters by near infrared spectrometry
2006
Abstract A chemometric method has been developed for the determination of acidity and peroxide index in edible oils of different types and origins by using near infrared spectroscopy (NIR) measurements. Different methods for selecting the calibration set, after an hierarchical cluster analysis, were applied. After discrimination of olive oils from maize, seed and sunflower, the prediction capabilities of partial least squares (PLS) multivariate calibration of NIR data were evaluated. Several preprocessing alternatives (first derivative, multiplicative scatter correction, vector normalization, constant offset elimination, mean centering and standard normal variate) were investigated by using…
Quantification of nortriptyline in plasma by HPLC and fluorescence detection
2009
Abstract A simple, sensitive and specific high-performance liquid chromatography method has been developed for the determination of nortriptyline (NT) in plasma samples. The assay involved derivatization with 9H-fluoren-9-ylmethyl chloroformate (Fmoc-Cl) and isocratic reversed-phase (C 18 ) chromatography with fluorescence detection. The developed method required only 100 μl of plasma sample, deproteinized and derivatized in one step. Calibration curves were lineal over the concentration range of 5–5000 ng/ml. The derivatization reaction was performed at room temperature in 20 min and the obtained NT derivative was stable for at least 48 h at room temperature. The within-day and between-day…
Determination of Paint Solvents by Vapour Phase Fourier Transform Infrared Spectrometry.
1997
Abstract A fast procedure has been developed for the direct determination of paint solvents. The method is based on the injection of small volumes of untreated solvent mixtures into a heated Pyrex glass reactor in which the sample is volatilized and introduced by means of a flow of nitrogen into an IR multiple pass gas cell and the spectrum in the mid-IR region is registered as a function of time. Data found for samples are interpolated in calibration graphs obtained by injecting different volumes of pure compounds which constitute the solvent mixture. A methylisobutylketone (MIBK) toluene mixture was used as test system to develop the proposed procedure. The method provides a limit of dete…
A Fully Automated Assembly Using Solenoid Valves for the Photodegradation and Chemiluminometric Determination of the Herbicide Chlorsulfuron
2005
Abstract This paper presents a new photochemiluminescent system for the determination of chlorsulfuron in water samples. The light from a low‐pressure mercury lamp is used as a clean, reproducible, and inexpensive “reagent” for the derivation of the pesticide, performed in glycine buffer at pH 9.5. Then, the photo‐products from irradiation are oxidized by permanganate in sulfuric acid solution. The oxidation reaction was favored by using high temperatures. A comparative study and discussion about the use of polyphosphoric acid instead of sulfuric acid in the oxidation reaction is also presented. The use of solenoid valves allows for the easy, complete automation of the process with low samp…
FI-on line photochemical reaction for direct chemiluminescence determination of photodegradated chloramphenicol.
2002
Abstract A new, simple, clean and selective flow injection strategy based on the tandem photochemical reaction-chemiluminescence detection was applied to the determination of chloramphenicol. The determination is based on the on-line photodegradation of the drug in a glycine buffer at pH 8.8 by using a photoreactor consisting of 697 cm×0.5 mm PTFE tubing helically coiled around an 8 W low-pressure mercury lamp. Photodegradated chloramphenicol is detected by direct chemiluminescence of resulting photo-fragments and their subsequent reaction with potassium permanganate in sulfuric acid medium as oxidant. The method allows the chemiluminescence determination of compounds which do not exhibit n…
Solid-Phase Microextraction Liquid Chromatography/Tandem Mass Spectrometry To Determine Postharvest Fungicides in Fruits
2003
A method to determine five postharvest fungicides (dichloran, flutriafol, o-phenylphenol, prochloraz, tolclofos methyl) in fruits (cherries, lemons, oranges, peaches) has been developed using solid-phase microextraction (SPME) coupled to liquid chromatography (LC) with photodiode array (DAD), mass spectrometry (MS), or tandem mass spectrometry (MS/MS) with ion trap detection. Extraction involved sample homogenization with an acetone/water solution (5:1), filtration, and acetone evaporation prior to fiber extraction. The pesticides were isolated with a fused-silica fiber coated with 50-microm Carbowax/template resin. The effects of pH, ion strength, sample volume, and extraction time were in…
Use of micellar mobile phases for the chromatographic determination of clorazepate, diazepam, and diltiazem in pharmaceuticals
2001
An ODS-2 column, a micellar mobile phase of high elution strength containing 0.1M sodium dodecyl sulfate and 3% (v/v) butanol, and ultraviolet detection at 230 nm are used for the determination of either of two benzodiazepines (clorazepate and diazepam) and a benzothiazepine (diltiazem) in pharmaceuticals. The procedure is shown to be competitive against conventional chromatography with methanol-water mobile phases, especially for diltiazem. The composition of the micellar mobile phase is selected using a predictive strategy based on an accurate retention model and assisted by computer simulation. Calibration graphs are linear at least in the 2.5 to 20 microg/mL, 4 to 20 microg/mL, and 5 to…
Identification of Leguminosae gums and evaluation of carob-guar mixtures by capillary zone electrophoresis of protein extracts.
2002
A procedure for the extraction and capillary zone electrophoresis (CZE) separation of proteins from carob, guar and tara gums in a background electrolyte (BGE) of pH 9 containing 0.1% polyvinyl alcohol is described. The CZE protein profiles exhibit characteristic peaks for each one of the Leguminosae gums, which can be used to construct models capable of identifying samples of carob, guar and tara gums, and predicting the guar content in binary carob-guar mixtures of different geographical origin and harvested in different years. The classification and prediction models are constructed by using linear discriminant analysis (LDA) and multiple linear regression (MLR), respectively. An excelle…
Identification of unknown pesticides in fruits using ultra-performance liquid chromatography–quadrupole time-of-flight mass spectrometry
2007
Abstract Ultra-high-performance liquid chromatography–quadrupole time-of-flight mass spectrometry (UPLC-QqTOF-MS) is an emerging technique offering more rapid and efficient separation, as well as the possibility to obtain accurate mass measurement and tandem mass spectrometry (MS/MS). This paper deals with the use of UPLC-QqTOF-MS to identify the pesticide residues present in complex pear extracts. Carbendazim, imazalil, and ethoxyquin were successfully identified because of the accurate mass determination of their protonated molecule and their major fragments in the product ion mass spectra. A few plastic and latex additives were also found, most of them probably coming from the packaging …
Determination of titanium by adsorption-voltammetry with 2-(5-bromo-2-pyridylazo)-5-(diethylamino)-phenol (5-Br-PADAP)
1990
The 1:1 complex between titanium (IV) and 5-Br-PADAP can be used to determine titanium by adsorption voltammetry at a stationary Hg-electrode. The experimental conditions for the determination are described. The detection limit is 3×10−10 mol/l Ti (0.015 ppb). Calibration curves are linear for solutions containing 4×10−10 to 5×10−8 mol/l Ti(IV) and an enrichment time of 3 min. The influence of foreign ions was investigated. The determination can be carried out in the presence of a 5000-fold excess of iron.