Search results for "Calibration"

showing 10 items of 890 documents

Design, Calibration, and Application of a Robust, Cost-Effective, and High-Resolution Lensless Holographic Microscope

2022

Lensless holographic microscope (LHM) is an emerging very promising technology that provides high-quality imaging and analysis of biological samples without utilizing any lens for imaging. Due to its small size and reduced price, LHM can be a very useful tool for the point-of-care diagnosis of diseases, sperm assessment, or microfluidics, among others, not only employed in advanced laboratories but also in poor and/or remote areas. Recently, several LHMs have been reported in the literature. However, complete characterization of their optical parameters remains not much presented yet. Hence, we present a complete analysis of the performance of a compact, reduced cost, and high-resolution LH…

Microscopyin-line holographic microscopy; digital holography; Gabor holography; lensless microscope; digital image processing; medical and biological imaging; microscope characterizationCost-Benefit Analysisin-line holographic microscopyChemical technologyHolographyTP1-1185microscope characterizationÒpticaOptometriadigital image processingdigital holographyBiochemistryArticleAtomic and Molecular Physics and OpticsAnalytical ChemistryGabor holographylensless microscopeCalibrationmedical and biological imagingElectrical and Electronic EngineeringInstrumentationLenses
researchProduct

Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy.

2006

We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detecto…

MiniaturizationQuality Assurance Health CareSettore FIS/01 - Fisica SperimentaleReproducibility of ResultsSpectrometry X-Ray EmissionEquipment DesignRadiation DosageSensitivity and SpecificitySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CdTe detectorEquipment Failure AnalysisCalibrationRadiometryCZT detectorsMammographyMedical physics
researchProduct

A statistical calibration model for Affymetrix probe level data

2009

Gene expression microarrays allow a researcher to measure the simultaneous response of thousands of genes to external conditions. Affymetrix GeneChip{ $Ⓡ$} expression array technology has become a standard tool in medical research. Anyway, a preprocessing step is usually necessary in order to obtain a gene expression measure. Aim of this paper is to propose a calibration method to estimate the nominal concentration based on a nonlinear mixed model. This method is an enhancement of a method proposed in Mineo et al. (2006). The relationship between raw intensities and concentration is obtained by using the Langmuir isotherm theory.

Mixed modelNonlinear systemMeasure (data warehouse)Calibration (statistics)Computer scienceLevel dataPreprocessorAffymetrix GeneChip Operating SoftwareSettore SECS-S/01 - StatisticaAlgorithmCalibration models microarray data pre-processingExpression (mathematics)
researchProduct

A nonlinear mixed model approach to predict energy expenditure from heart rate.

2021

Abstract Objective. Heart rate (HR) monitoring provides a convenient and inexpensive way to predict energy expenditure (EE) during physical activity. However, there is a lot of variation among individuals in the EE-HR relationship, which should be taken into account in predictions. The objective is to develop a model that allows the prediction of EE based on HR as accurately as possible and allows an improvement of the prediction using calibration measurements from the target individual. Approach. We propose a nonlinear (logistic) mixed model for EE and HR measurements and an approach to calibrate the model for a new person who does not belong to the dataset used to estimate the model. The …

Mixed modelsykePhysiologyComputer science0206 medical engineeringindividual calibrationBiomedical EngineeringBiophysicsPhysical activityphysical activityheart rate monitoringModel parameters02 engineering and technologykalibrointilogistinen sekamallisykemittaus [energiankulutus]03 medical and health sciences0302 clinical medicineHeart RatePhysiology (medical)energy expenditureCalibrationHumanslogistic mixed modeltilastolliset mallitExerciseMonitoring PhysiologicHeterogeneous groupPrediction interval020601 biomedical engineeringmittausmenetelmätNonlinear systemEnergy expenditureExercise TestsykemittaritEnergy Metabolismfyysinen aktiivisuus.Algorithmfyysinen aktiivisuusenergiankulutus (aineenvaihdunta)030217 neurology & neurosurgeryPhysiological measurement
researchProduct

Electrochemical detection of the 2-isobutyl-3-methoxypyrazine model odorant based on odorant-binding proteins: The proof of concept

2014

Abstract We developed an electrochemical assay for the detection of odorant molecules based on a rat odorant-binding protein (rOBP3). We demonstrated that rOBP3 cavity binds 2-methyl-1,4-naphtoquinone (MNQ), an electrochemical probe, as depicted from the decrease of its electrochemical signal, and deduced the dissociation constant, Kd MNQ  = 0.5(± 0.2) μM. The amount of MNQ displaced from rOBP3 by 2-isobutyl-3-methoxypyrazine (IBMP), a model odorant molecule, was measured using square-wave voltammetry. The release of MNQ by competition led to an increase of the electrochemical response. In addition, this method allowed determination of the dissociation constant of rOBP3 for IBMP, Kd IBMP  =…

Models MolecularIsothermal microcalorimetryOdorant bindingBiophysicsAnalytical chemistryCalorimetryReceptors OdorantElectrochemistryBinding CompetitiveCaffeic AcidsElectrochemistryPhysical and Theoretical ChemistryVoltammetryBinding SitesChemistryVitamin K 3Electrochemical TechniquesGeneral MedicineCombinatorial chemistryFluorescenceRecombinant ProteinsDissociation constantImmobilized ProteinsSpectrometry FluorescencePyrazinesCalibrationTitrationBiosensorBioelectrochemistry
researchProduct

Size-Exclusion Chromatographic Determination of Polymer Molar Mass Averages Using a Fractal Calibration

2005

The characterization of polymers by size-exclusion chromatography basically consists of the determination of the weight-average molar mass (Mw), number-average molar mass (Mn), and polydispersity index (I). An accurate estimation of these magnitudes requires the use of a reliable and trusted calibration curve. Three procedures for building up a calibration curve are analyzed in this work. The first is the classical universal calibration (UC), based on the elution of tetrahydrofuran-polystyrene in a system as reference. The second is based on the proper calibration curve made with standards of the sample under study. However, two main drawbacks arise when using these methodologies: the nonfu…

Molar massChromatographyFractalCalibration curveElutionCalibration (statistics)ChemistrySize-exclusion chromatographyAnalytical chemistryMolar mass distributionGeneral MedicineAnalytical ChemistrySeparation processJournal of Chromatographic Science
researchProduct

Exploring the effect of absence selection on landslide susceptibility models: A case study in Sicily, Italy

2016

Abstract A statistical approach was employed to model the spatial distribution of rainfall-triggered landslides in two areas in Sicily (Italy) that occurred during the winter of 2004–2005. The investigated areas are located within the Belice River basin and extend for 38.5 and 10.3 km 2 , respectively. A landslide inventory was established for both areas using two Google Earth images taken on October 25th 2004 and on March 18th 2005, to map slope failures activated or reactivated during this interval. Geographic Information Systems (GIS) were used to prepare 5 m grids of the dependent variables (absence/presence of landslide) and independent variables (lithology and 13 DEM-derivatives). Mul…

Multivariate Adaptive Regression Splines (MARS)Geographic information system010504 meteorology & atmospheric sciencesCalibration (statistics)Lithologymedia_common.quotation_subjectSettore GEO/04 - Geografia Fisica E GeomorfologiaGeographic Information Systems (GIS)010502 geochemistry & geophysicsSpatial distribution01 natural sciencesSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-ForestaliGeographic Information Systems (GIS); Google Earth; Landslide susceptibility; Multivariate Adaptive Regression Splines (MARS); Earth-Surface Processes0105 earth and related environmental sciencesmedia_commonEarth-Surface ProcessesVariablesMultivariate adaptive regression splinesReceiver operating characteristicbusiness.industryGoogle EarthLandslideLandslide susceptibilitybusinessCartographyGeology
researchProduct

New cut-off criterion for uninformative variable elimination in multivariate calibration of near-infrared spectra for the determination of heroin in …

2008

A new cut-off criterion has been proposed for the selection of uninformative variables prior to chemometric partial least squares (PLS) modelling. After variable elimination, PLS regressions were made and assessed comparing the results with those obtained by PLS models based on the full spectral range. To assess the prediction capabilities, uninformative variable elimination (UVE)-PLS and PLS were applied to diffuse reflectance near-infrared spectra of heroin samples. The application of the proposed new cut-off criterion, based on the t-Students distribution, provided similar predictive capabilities of the PLS models than those obtained using the original criteria based on quantile value. H…

Multivariate analysisModels StatisticalSpectroscopy Near-InfraredChemistryIllicit DrugsRepeatabilityBiochemistryAnalytical ChemistryChemometricsHeroinModels ChemicalPartial least squares regressionStatisticsCalibrationCalibrationRange (statistics)Environmental ChemistryCluster AnalysisComputer SimulationVariable eliminationSpectroscopyQuantileAnalytica chimica acta
researchProduct

Multivariate regression analysis applied to the calibration of equipment used in pig meat classification in Romania.

2016

This paper highlights the statistical methodology used in a dissection experiment carried out in Romania to calibrate and standardize two classification devices, OptiGrade PRO (OGP) and Fat-o-Meat'er (FOM). One hundred forty-five carcasses were measured using the two probes and dissected according to the European reference method. To derive prediction formulas for each device, multiple linear regression analysis was performed on the relationship between the reference lean meat percentage and the back fat and muscle thicknesses, using the ordinary least squares technique. The root mean squared error of prediction calculated using the leave-one-out cross validation met European Commission (EC…

Multivariate statisticsMeatMean squared errorFood HandlingSwine0211 other engineering and technologies02 engineering and technologyCross-validationStatisticsCalibrationMedicineAnimals021110 strategic defence & security studiesbusiness.industryBack fatRomania0402 animal and dairy scienceRegression analysis04 agricultural and veterinary sciences040201 dairy & animal scienceAdipose TissueOrdinary least squaresCalibrationBody CompositionMultiple linear regression analysisbusinessFood ScienceMeat science
researchProduct

Determination of vinegar acidity by attenuated total reflectance infrared measurements through the use of second-order absorbance-pH matrices and par…

2007

Univariate (zero-order), multivariate (first-order) and multiway (second-order) calibrations were assayed for the determination of vinegar acidity using a mechanized procedure based upon vibrational spectroscopy and the emerging multicommutation methodology. The second-order methodology relies on the use of a flow system based on multicommutation and binary sampling. The flow network comprises a set of three-way solenoid valves, computer-controlled to provide facilities to handle the sample and to generate a time-dependent pH gradient using two carrier solutions. The procedure is based on the volumetric fraction variation approach that maintains the same volume of sample solution and dynami…

Multivariate statisticsSpectrophotometry InfraredChemistryAnalytical chemistrySampling (statistics)Hydrogen-Ion ConcentrationAnalytical ChemistryChemometricsAbsorbanceAttenuated total reflectionPartial least squares regressionCalibrationTitrationFactor Analysis StatisticalAcetic AcidTalanta
researchProduct