Search results for "Calibration"

showing 10 items of 890 documents

2017

In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of γ-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 108 n s−1cm−2 at the target position and negligible neutron halo. The target was surrounded by an array of eight to ten anti-Compton shielded EXOGAM Clover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the…

PhysicsPhysics::Instrumentation and Detectors010308 nuclear & particles physicsFissionAstrophysics::High Energy Astrophysical PhenomenaDetectorNeutron radiation01 natural sciencesCollimated lightSemiconductor detectorNuclear physicsMicrosecond0103 physical sciencesCalibrationNeutron010306 general physicsInstrumentationMathematical PhysicsJournal of Instrumentation
researchProduct

Software Timing Calibration of the ARGO-YBJ Detector

2009

The ARGO-YBJ experiment is mainly devoted to search for astronomical gamma sources. The arrival direction of air showers is reconstructed thanks to the times measured by the pixels of the detector. Therefore, the timing calibration of the detector pixels is crucial in order to get the best angular resolution and pointing accuracy. Because of the large number of pixels a hardware timing calibration is practically impossible. Therefore an off-line software calibration has been adopted. Here, the details of the procedure and the results are presented. (C) 2008 Elsevier B.V. All rights reserved.

PhysicsPixelCalibration (statistics)business.industryPhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaDetectorSettore FIS/01 - Fisica SperimentaleComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONAstrophysics::Instrumentation and Methods for AstrophysicsAstronomy and AstrophysicsAstronomia gammaGamma Astronomy Timing Calibration Extensive Air ShowersSciami estesiCalibrazione temporaleOpticsSoftwareRaggi cosmiciSettore FIS/05 - Astronomia e AstrofisicaAngular resolutionbusinessArgoRemote sensing
researchProduct

Calibration of a camera-projector monochromatic system

2015

Camera–projector systems are increasingly being used in many different applications, including object reconstruction. In recent years, a number of approaches have been proposed to calibrate such devices; in this paper a calibration method is presented which can be used with monochromatic systems. The method is based on open-source code, makes use of planar calibration patterns, is fully automatic, easy to use and fast. Additionally, no initial information regarding the camera interior orientation is needed, and both sensors (camera and projector) are fully calibrated during the process. The method is validated by a series of tests, where root mean square errors (RMSEs) in image space are ke…

PhysicsProjector calibration0202 electrical engineering electronic engineering information engineeringEarth and Planetary Sciences (miscellaneous)020207 software engineering020201 artificial intelligence & image processing02 engineering and technologyComputers in Earth SciencesEngineering (miscellaneous)HumanitiesCartographyComputer Science ApplicationsThe Photogrammetric Record
researchProduct

Low Energy Protons at RADEF - Application to Advanced eSRAMs

2014

A low energy proton facility has been developed at RADEF, Jyvskyl, Finland. The proton energy selection, calibration and dosimetry are described. The first experiment with external users was performed using two memory test vehicles fabricated with 28 nm technology. Examples of single event upset measurements in the test vehicles embedded SRAMs (eSRAMs) as a function of proton energy are provided.

PhysicsProtonta114ta213business.industryNuclear engineeringElectrical engineeringProton energySEE testLow energyLow energy proton facilitySingle event upsetCalibrationDosimetryMemory testbusiness
researchProduct

Technology of p-type microstrip detectors with radiation hard p-spray, p-stop and moderated p-spray insulations

2007

5 pages, 8 figures.-- PACS nrs.: 29.40.Gx; 29.40.-- ISI Article Identifier: 000249604700010.

PhysicsRadiation hardnessNuclear and High Energy PhysicsFabricationbusiness.industryDetectorCapacitanceMicrostripMicrostrip detectorsSuper-LHCInsulationCalibrationOptoelectronicsbusiness[PACS] Tracking and position-sensitive detectorsInstrumentationRadiation hardeningDiodeVoltage
researchProduct

Cosmic ray effect on the X-ray Trigger Telescope of UFFO/Lomonosov using YSO scintillation crystal array in space

2017

UFFO Burst Alert and Trigger telescope (UBAT) is the X-ray trigger telescope of UFFO/Lomonosov to localize X-ray source with coded mask method and X-ray detector. Its X-ray detector is made up of 36 8×8 pixels Yttrium OxyorthoSilicate (Y2SiO5:Ce, YSO) scintillation crystal arrays and 36 64-channel Multi-Anode PhotoMultiplier Tubes (MAPMTs) for space mission. Its effective detection area is 161cm2 and energy range is several keV to 150 keV. It was successfully launched in April 28, 2016. In several calibration run, we got several X-ray background data. We already knew X-ray background flux is 2-3 counts/cm2/sec in space. However our X-ray background data shows approximately 7-8 times higher …

PhysicsScintillationPhotomultiplierPhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaDetectorAstronomyFluxCosmic rayAstrophysicslaw.inventionTelescopeCrystallawCalibrationProceedings of 35th International Cosmic Ray Conference — PoS(ICRC2017)
researchProduct

Low-noise microvolt level calibrator for measurement of performance of biosignal recording systems

1997

A calibrator, the noise level of which is below the noise level generated in the preamplifier system, was needed for testing and development of a multichannel recording system. A multichannel preamplifier head assembly was used for recording cortical, subcortical, and cerebellar slow potentials and multiunit activity in freely moving cats and restrained rabbits. An inexpensive, battery-powered, lownoise voltage signal generator for calibration of the preamplifiers is described. The circuit provides a square-wave output at a frequency of 10 or 1000 Hz, and the peak-to-peak (p-p) amplitude can be selected at 10, 100, or 1000µV. The measured output noise of the calibrator is below 2µV (p-p, 0.…

PhysicsSignal generatorNoise (signal processing)Preamplifierbusiness.industryAcousticsExperimental and Cognitive PsychologyAmplitudeCalibrationPsychology (miscellaneous)BiosignalOscilloscopeTelecommunicationsbusinessGeneral PsychologyVoltageBehavior Research Methods, Instruments, & Computers
researchProduct

Precise measurement of the dynamical masses in AB Doradus

2007

AbstractThe radio stars ABDor A and ABDor B (=Rst137B) are the main components of the ABDoradus system. Both stars are double (ABDor A/ABDor C and ABDor Ba/ABDor Bb) and usual targets of astrometric instruments at optical (Hipparcos), infrared (VLT), and radio (VLBI) wavelengths. From a combination of all astrometric data available, we have obtained precise limits to the dynamical mass of both binaries in AB Doradus. The determination of the mass of ABDor C (0.090±0.003 M⊙) is important, since this object constitutes one of the few calibration points used to test theoretical evolutionary models of low-mass young stars. Follow-up observations both in radio (VLBI) and optical wavelengths (VLT…

PhysicsStarsWavelengthSpace and Planetary ScienceInfraredVery-long-baseline interferometryCalibrationAstronomyAstronomy and AstrophysicsAstrophysicsAstrometryProceedings of the International Astronomical Union
researchProduct

Reply to “Comment on ‘Correspondence factor for Nucletron surface applicators'” [Med. Phys. 39, 2947-2948 (2012)]

2012

PhysicsSurface (mathematics)OpticsCalibration (statistics)business.industryGeneral MedicinebusinessMedical Physics
researchProduct

Reduction of the uncertainty in the measurements of magnetic fields

2014

The paper deals with magnetic field measurement, carried out by using a broadband and isotropic instrument. These measurements are characterized by a very high uncertainty values if compared with the ones usually related to other electrical measurements. For these reasons, if the measurements are performed to assess the exposure of human beings, these large uncertainty values imply a high risk of wrong decision when there is the need to establish if a site complies or does not comply with a specified emission limits. A reduction of the uncertainty values implies a reduction of the risk. With this aim, we propose an approach which, in particular but very typical cases, allows an effective re…

PhysicsSustainability and the EnvironmentMagnetoresistancebusiness.industrymagnetic field measurementsIsotropyElectrical engineeringmeasurement uncertainty.Magnetic fieldReduction (complexity)Control theorymagnetic field measurementmeasurement uncertaintyCalibrationSettore ING-IND/09 - Sistemi per l'Energia e L'AmbienteMeasurement uncertaintyElectrical measurementsRenewable EnergyInstrumentation (computer programming)businessSettore ING-INF/07 - Misure Elettriche E Elettronichemagnetic field measurements; measurement uncertainty; Renewable Energy Sustainability and the Environment2014 International Conference on Renewable Energy Research and Application (ICRERA)
researchProduct