Search results for "Calibration"
showing 10 items of 890 documents
Measuring intrinsic thickness of rough membranes: application to nanofibrillated cellulose films
2015
Adequate measurement of thickness of sheet-like materials or membranes is most important for quantifying their properties such as density, barrier properties and mechanical strength. Depending on the surface roughness of the membrane, the thickness measured by standard micrometre devices (apparent thickness) may considerably overestimate the actual geometrical mean thickness (intrinsic thickness) required for such purposes. In this work, we present a method for correcting the measured apparent thickness value of thin membranes for their surface roughness, thereby obtaining an improved estimate of the intrinsic thickness. The surface roughness data required for the correction can be obtained…
Alignment for the first precision measurements at Belle II
2019
On March 25th 2019, the Belle II detector recorded the first collisions delivered by the SuperKEKB accelerator. This marked the beginning of the physics run with vertex detector. The vertex detector was aligned initially with cosmic ray tracks without magnetic field simultaneously with the drift chamber. The alignment method is based on Millepede II and the General Broken Lines track model and includes also the muon system or primary vertex position alignment. To control weak modes, we employ sensitive validation tools and various track samples can be used as alignment input, from straight cosmic tracks to mass-constrained decays. With increasing luminosity and experience, the alignment is …
Comparison of quantitative analysis techniques for the determination of heat seal lacquer layers on aluminum blister foils
2010
For decades a gravimetric method has been common standard for the determination of heat seal lacquers on aluminum blister foils. With the availability of appropriate techniques such as interferometric, infrared reflection absorption spectroscopic (IRRAS), beta backscatter, impedance spectroscopic and eddy current techniques respectively, more efficient determinations can be foreseen which are subject of the present communication. The different methods were compared to each other regarding parameters required for validation of analytical procedures according to the ICH guidelines Q2 (R1) such as linearity, precision, accuracy, robustness and quantitation limits. The interferometric, IRRAS an…
Quality control Fourier transform infrared determination of diazepam in pharmaceuticals
2007
A quality control procedure has been developed for the determination of diazepam in pharmaceuticals using Fourier transform infrared (FTIR) spectroscopy. The method involves the off-line extraction of diazepam with chloroform by sonication and direct determination in the extracts through peak area measurement in the interval between 1672 and 1682 cm(-1) using a baseline correction defined between 1850 and 1524 cm(-1). For standardization it was used an external calibration line established from standard solutions of diazepam in chloroform. The method provides a limit of detection of 0.04 mg per tablet (n=5), a relative standard deviation (R.S.D.) of 0.5% for 5 independent measurements of a …
Pressurized liquid extraction combined with capillary electrophoresis–mass spectrometry as an improved methodology for the determination of sulfonami…
2007
A new analytical method, based on capillary electrophoresis and tandem mass spectrometry (CE-MS2), is proposed and validated for the identification and simultaneous quantification of 12 sulfonamides (SAs) in pork meat. The studied SAs include sulfathiazole, sulfadiazine, sulfamethoxypyridazine, sulfaguanidine, sulfanilamide, sulfadimethoxyne, sulfapyridine, sulfachloropyridazine, sulfisoxazole, sulfasalazine, sulfabenzamide and sulfadimidine. Different parameters (i.e. separation buffer, sheath liquid, electrospray conditions) were optimized to obtain an adequate CE separation and high MS sensitivity. MS2 experiments using an ion trap as analyzer, operating in the selected reaction monitori…
Comparison of two partial least squares infrared spectrometric methods for the quality control of pediculosis lotions.
2006
Two vibrational spectroscopy procedures have been developed and compared for the direct and simultaneous determination of piperonyl butoxide and tetramethrin, the active ingredients of alcoholic capillary lotions, for hair pediculosis diseases. Nine lotions, purchased from the Spanish market, were analyzed using both, attenuated total reflectance (ATR) and transmission FT-IR measurements, and based on the use of partial least squares (PLS) multivariate calibration. A reduced set of 15 matched standards (11 for calibration and 4 for validation) was employed using both measurement modes. The spectral wave number ranges between 1757 and 1712 cm(-1) was selected to determine tetramethrin by bot…
Detection of batch effects in liquid chromatography-mass spectrometry metabolomic data using guided principal component analysis.
2014
Metabolomics based on liquid chromatography-mass spectrometry (LC-MS) is a powerful tool for studying dynamic responses of biological systems to different physiological or pathological conditions. Differences in the instrumental response within and between batches introduce unwanted and uncontrolled data variation that should be removed to extract useful information. This work exploits a recently developed method for the identification of batch effects in high throughput genomic data based on the calculation of a delta statistic through principal component analysis (PCA) and guided PCA. Its applicability to LC-MS metabolomic data was tested on two real examples. The first example involved t…
Enantiomeric quality control of antihistamines in pharmaceuticals by affinity electrokinetic chromatography with human serum albumin as chiral select…
2007
The present paper deals with the enantiomeric separation of six antihistaminic enantiomers by affinity electrokinetic chromatography (AEKC)-partial filling technique using human serum albumin (HSA) as chiral selector. A multivariate optimization approach of the most critical experimental variables in enantioresolution, running pH, HSA concentration and HSA plug length (SPL) was carried out since there are interactions between variables that could not be considered in an univariate optimization. The estimated and experimental resolution values obtained for antihistaminic enantiomers varied from 1.13 (for orphenadrine) to 2.15 (for brompheniramine). The optimum experimental conditions for ena…
Plasma pharmacokinetics and tissue distribution study of cajaninstilbene acid in rats by liquid chromatography with tandem mass spectrometry
2010
Cajaninstilbene acid (CSA; 3-hydroxy-4-prenyl-5-methoxystilbene-2-carboxylic acid) is a major active constituent of pigeonpea leaves, has been proven to be effective in clinical treatment of diabetes, hepatitis, measles and dysentery. A rapid and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of CSA in rat plasma and various tissues (brain, heart, lung, liver, spleen, small intestine and kidney) of rat for the first time. Rat plasma and tissue distribution pre-treated by protein precipitation with acetoacetate was analyzed using LC-MS/MS with an electrospray ionization (ESI) interface, and isoliquiritigenin was us…
"Historical pigments characterisation by quantitative X-ray fluorescence"
2014
Abstract Most of the historical paints are mainly constituted by inorganic pigments, either pure or mixed, spread on the surfaces using different binding agents. The knowledge of the exact amount of different constituents of the paint, as well as of the mixing and pictorial techniques, is crucial for a careful program of conservation of polychrome works. Moreover, since the availability of these pigments has been changing through the centuries, their identification and chemical characterisation is useful to acquire or deepen information about the artist and his/her work. This information can also be useful for authentication purposes through relative dating because the identification of one…