Search results for "Calibration"

showing 10 items of 890 documents

Flow cytometric kinetic assay of the activity of Na+/H+ antiporter in mammalian cells.

2004

Background The Na+/H+ exchanger (NHE) of mammalian cells is an integral membrane protein that extrudes H+ ion in exchange for extracellular Na+ and plays a crucial role in the regulation of intracellular pH (pHi). Thus, when pHi is lowered, NHE extrudes protons at a rate depending of pHi that can be expressed as pH units/s. Methods To abolish the activity of other cellular pH-restoring systems, cells were incubated in bicarbonate-free Dulbecco's modified Eagle's medium buffered with HEPES. Flow cytometry was used to determine pHi with 2′,7′-bis-(2-carboxyethyl)-5-(and-6)-carboxyfluorescein acetoxymethyl ester or 5-(and-6)-carboxy SNARF-1 acetoxymethyl ester acetate, and the appropriate fluo…

Sodium-Hydrogen ExchangersTime FactorsNigericinIntracellular pHBiophysicsIonophoreNaphtholsBiochemistryModels BiologicalPathology and Forensic MedicineFlow cytometryCell Linechemistry.chemical_compoundJurkat CellsMiceEndocrinologyChondrocytesIschemiamedicineExtracellularAnimalsHumansBenzopyransMuscle SkeletalCells CulturedFluorescent DyesHEPESmedicine.diagnostic_testDose-Response Relationship DrugRhodaminesCell BiologyHematologyHydrogen-Ion ConcentrationFlow CytometryFluoresceinsAmilorideKineticsBiochemistrychemistryCell cultureCalibrationNIH 3T3 Cellsmedicine.drugCytometry. Part A : the journal of the International Society for Analytical Cytology
researchProduct

Closure to “Laboratory and Field Calibration of the Diviner 2000 Probe in Two Types of Soil” by J. Haberland, R. Gálvez, C. Kremer, and C. Carter

2015

The authors deal with the quite interesting and actual problem of Diviner 2000 capacitance probe calibration and present some field and laboratory data obtained on two different layers (0–0.26 and 0.26–0.50 cm) of the same soil profile, characterized by different textural class. The importance of site-specific calibration of sensors used to monitor soil or plant water status assumes a particular relevance in semiarid environments where the application of precision irrigation represents an appropriate management strategy aimed to achieve high values of water use efficiency (Cammalleri et al. 2013). Moreover, in clay soils, physical properties are strongly influenced by soil water content (Pr…

Soil scienceSoil typeAgricultural and Biological Sciences (miscellaneous)Soil waterSoil horizonEnvironmental scienceField calibrationGeotechnical engineeringCapacitance probeWater-use efficiencyAir gap (plumbing)Water Science and TechnologyCivil and Structural EngineeringDivinerJournal of Irrigation and Drainage Engineering
researchProduct

Assessing Field and Laboratory Calibration Protocols for the Diviner 2000 Probe in a Range of Soils with Different Textures

2016

Frequency domain reflectometry (FDR) downhole sensors have been increasingly used for soil moisture field monitoring because they allow measurement, even continuously, along a soil profile. Moreover, they can also be installed with minimal soil disturbance around the access tube. The objectives of the paper were to assess the field and laboratory calibration protocols for a FDR capacitance probe (Diviner 2000) for a range of soils characterized by different particle size distributions and shrink/swell potential and to propose a practical and effective protocol on the basis of undisturbed soil samples, accounting for soil shrinkage/swelling processes characterizing swelling clay soils. The e…

Soil test0208 environmental biotechnologyShrinking/swellings soilCalibration protocolsSoil science02 engineering and technologySoil water contentCapacitance probeFrequency domain reflectometry (FDR); Capacitance probe; Soil water content; Dielectric permittivity; Shrinking/ swellings soils; Calibration protocols.Dielectric permittivityShrinking/ swellings soilsCalibrationReflectometryFrequency domain reflectometry (FDR)Water contentWater Science and TechnologyCivil and Structural EngineeringCalibration protocol04 agricultural and veterinary sciencesAgricultural and Biological Sciences (miscellaneous)Swell020801 environmental engineeringSoil water040103 agronomy & agriculture0401 agriculture forestry and fisheriesEnvironmental scienceSoil horizonCapacitance probeJournal of Irrigation and Drainage Engineering
researchProduct

Optimization criteria in sample selection step of local regression for quantitative analysis of large soil NIRS database

2012

International audience; Large soil spectral libraries compiling thousands of NIR (Near Infrared) reflectance spectra have been created encompassing a wide diversity and heterogeneity of spectra. Among the many chemometric approaches to the calibration of chemical and physical properties from these large libraries, local calibrations have the advantage of being able to select the most similar spectra to the spectrum of a target sample. This is particularly relevant when dealing with highly heterogeneous media such as soils, where the mineral matrix has a strong influence on spectral features. A crucial step in the implementation of local calibration procedures is the construction of local ne…

Soil testCorrelation coefficientnear infrared spectroscopy[SDV]Life Sciences [q-bio]Fast Fourier transformfast fourier transformsample selection010501 environmental sciences01 natural sciencesAnalytical ChemistryStatisticsPartial least squares regressionsoil spectral databaseSpectroscopySelection (genetic algorithm)0105 earth and related environmental sciencesMathematicscompression methodsMahalanobis distancelocal calibrationbusiness.industryProcess Chemistry and TechnologyLocal regressionPattern recognition04 agricultural and veterinary sciences15. Life on landComputer Science Applications[SDE]Environmental SciencesPrincipal component analysis040103 agronomy & agriculture0401 agriculture forestry and fisheriesArtificial intelligencebusinessSoftwareChemometrics and Intelligent Laboratory Systems
researchProduct

A simplified approach to estimate water retention for Sicilian soils by the Arya-Paris model

2014

Application of the Arya and Paris (AP) model to estimate the soil water retention curve requires a detailed description of the particle-size distribution (PSD) because the scale factor a, relating the pore length of an ideal soil to that of the natural one, depends on the particle size distribution parameters. For a dataset of 140 Sicilian soils that were grouped in five texture groups, the logistic and linear models were applied to evaluate a, and the water retention values predicted by the AP model were compared with the measured ones. Using the parameters proposed by Arya et al. (1999), the two models yielded similar unsystematic root mean error of estimate (RMSEu). Therefore, their pote…

Soil water retention curve Particle size distribution Arya-Paris modelMean squared errorCalibration (statistics)Water retention curveSoil waterStatisticsLinear modelSoil ScienceSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-ForestaliLogistic regressionScale parameterWater contentMathematics
researchProduct

Determination of lidocaine in urine at low ppm levels using dispersive microextraction and attenuated total reflectance–Fourier transform infrared me…

2015

Abstract IR spectra provide valuable information about biological systems and can be obtained with compactable and affordable instruments, but the lack of sensitivity of this technique hampers its use in the determination of drugs in clinical fluids. Taking lidocaine as a target molecule, in this paper we introduced a methodology for determining drugs in urine samples using infrared spectroscopy. The lack of sensitivity of the IR was compensated with the combination of an effective and straightforward dispersive liquid–liquid microextraction and the measurement of the dry film of the organic extracts through attenuated total reflectance (ATR). The method developed improves the sensitivity b…

SolventDetection limitAnalyteChromatographyChemistryAttenuated total reflectionPartial least squares regressionAnalytical chemistryCalibrationInfrared spectroscopyUrineSpectroscopyAnalytical ChemistryMicrochemical Journal
researchProduct

FINDUS: An Open-Source 3D Printable Liquid-Handling Workstation for Laboratory Automation in Life Sciences

2020

3D-printed laboratory devices can enable ambitious research purposes even at a low-budget level. To follow this trend, here we describe the construction, calibration, and usage of the FINDUS (Fully Integrable Noncommercial Dispensing Utility System). We report the successful 3D printing and assembly of a liquid-handling workstation for less than $400. Using this setup, we achieve reliable and flexible liquid-dispensing automation with relative pipetting errors of less than 0.3%. We show our system is well suited for several showcase applications from both the biology and chemistry fields. In support of the open-source spirit, we make all 3D models, assembly instructions, and source code ava…

Source codeWorkstationComputer sciencemedia_common.quotation_subject3D printingcomputer.software_genre01 natural sciencesBiological Science DisciplinesCathepsin Blaw.invention03 medical and health scienceslawArduinoHumansSolid-Phase Synthesis Techniques030304 developmental biologymedia_commoncomputer.programming_languageAutomation Laboratory0303 health sciences010405 organic chemistrybusiness.industryPython (programming language)Automation0104 chemical sciencesComputer Science ApplicationsMedical Laboratory TechnologyOpen sourceCalibrationPrinting Three-DimensionalLaboratory automationOperating systemPeptidesbusinesscomputerSoftwareSLAS Technology
researchProduct

Proximal-sensing-powered modelling of energy-water fluxes in a vineyard: A spatial resolution analysis

2021

Spatial resolution is a key parameter in energy–water surface flux modelling. In this research, scale effects are analyzed on fluxes modelled with the FEST-EWB model, by upscaling both its inputs and outputs separately. The main questions are: (a) if high-resolution remote sensing images are necessary to accurately model a heterogeneous area; and (b) whether and to what extent low-resolution modelling provides worse/better results than the upscaled results of high-resolution modelling. The study area is an experimental vineyard field where proximal sensing images were obtained by an airborne platform and verification fluxes were measured via a flux tower. Modelled fluxes are in line with th…

Spatial resolutionPixelEvapotranspirationEnergy-balance modelScienceQVineyardSpatial heterogeneityFlux (metallurgy)Approximation errorEvapotranspirationUpscalingCalibrationGeneral Earth and Planetary SciencesEnvironmental scienceImage resolutionEnergy (signal processing)Settore ICAR/06 - Topografia E CartografiaRemote sensing
researchProduct

Assessment of image quality of intracoronary ultrasound systems with tissue-equivalent vessel phantoms

2002

Imaging of vascular structures by intracoronary ultrasound (ICUS) is finding more and more applications in coronary diagnosis and in the assessment of interventional access. The authors describe a method for easy and quick production of tissue-equivalent vessel phantoms from a special hydrocolloid. The mechanical tolerance is less than 3/100 mm. With these phantoms the authors tested the calibration and measured the resolution properties of the SONOS intravascular ultrasonic system (Hewlett Packard). The measurements revealed a slight space related underestimation of diameters up to 280 /spl mu/m. Using cross correlation and auto correlation functions the authors analyzed digitized ultrason…

Speckle patternTissue equivalentmedicine.medical_specialtyMaterials scienceCross-correlationImage qualityResolution (electron density)CalibrationmedicineIntracoronary ultrasoundUltrasonic sensorRadiologyBiomedical engineeringComputers in Cardiology 1994
researchProduct

Rapid and Nondestructive Determination of Egg Freshness Category and Marked Date of Lay using Spectral Fingerprint

2020

The potential of nondestructive prediction of egg freshness based on near-infrared (NIR) spectra fingerprints would be beneficial to quality control officers and consumers alike. In this study, handheld NIR spectrometer in the range of 740 nm to 1070 nm and chemometrics were used to simultaneously determine egg freshness based on marked date of lay for eggs stored under cold and ambient conditions. The spectra acquired from the eggs were preprocessed using multiplicative scatter correction and principal component analysis (MSC-PCA). Linear discriminant analysis (LDA) was used to build identification model to predict the category of freshness, while partial least square regression (PLS-R) wa…

SpectrometerArticle Subjectbusiness.industry010401 analytical chemistry0402 animal and dairy scienceCold storagePattern recognitionQC350-46704 agricultural and veterinary sciencesOptics. LightLinear discriminant analysis040201 dairy & animal science01 natural sciencesAtomic and Molecular Physics and Optics0104 chemical sciencesAnalytical ChemistryChemometricsFingerprintPartial least squares regressionPrincipal component analysisCalibrationArtificial intelligencebusinessSpectroscopyMathematicsJournal of Spectroscopy
researchProduct