Calibration of the RPC charge readout in the ARGO-YBJ experiment

2012

""The charge readout of Resistive Plate Chambers (RPCs) is implemented in the ARGO-YBJ experiment to measure the charged particle density of the shower front up to 10^4\\\/m^2, enabling the study of the primary cosmic rays with energies in the ''knee'' region. As the first time for RPCs being used this way, a telescope with RPCs and scintillation detectors is setup to calibrate the number of charged particles hitting a RPC versus its charge readout. Air shower particles are taken as the calibration beam. The telescope was tested at sea level and then moved to the ARGO-YBJ site for coincident operation with the ARGO-YBJ experiment. The charge readout shows good linearity with the particle de…

Optical telescopesNuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsCamere a Piastre Resistive (RPC)Resistive plate chamberAstrophysics::High Energy Astrophysical PhenomenaCosmic raylaw.inventionTelescopeSettore FIS/05 - Astronomia E AstrofisicaOpticslawCoincidentAir showersCalibrationSea levelInstrumentationParticle densitiesCosmic raysResistive Plate Chambers Charge read-out Extended Air ShowersPhysicsAir showers Charge readout Dynamic range Knee regions Particle densities Resistive plate chambers; Calibration Charged particles Cosmic rays Experiments Optical telescopes Sea level Telescopes; Particle spectrometersResistive touchscreenScintillationDynamic rangeCharge readoutParticle spectrometersbusiness.industryCharged particlesSettore FIS/01 - Fisica SperimentaleAstrophysics::Instrumentation and Methods for AstrophysicsCharged particleAir showerCalibrazione della Risposta Analogica di RPCKnee regionsLettura Analogica di RPCCalibrationResistive plate chambersbusinessExperimentsTelescopes
researchProduct

Software Timing Calibration of the ARGO-YBJ Detector

2009

The ARGO-YBJ experiment is mainly devoted to search for astronomical gamma sources. The arrival direction of air showers is reconstructed thanks to the times measured by the pixels of the detector. Therefore, the timing calibration of the detector pixels is crucial in order to get the best angular resolution and pointing accuracy. Because of the large number of pixels a hardware timing calibration is practically impossible. Therefore an off-line software calibration has been adopted. Here, the details of the procedure and the results are presented. (C) 2008 Elsevier B.V. All rights reserved.

PhysicsPixelCalibration (statistics)business.industryPhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaDetectorSettore FIS/01 - Fisica SperimentaleComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONAstrophysics::Instrumentation and Methods for AstrophysicsAstronomy and AstrophysicsAstronomia gammaGamma Astronomy Timing Calibration Extensive Air ShowersSciami estesiCalibrazione temporaleOpticsSoftwareRaggi cosmiciSettore FIS/05 - Astronomia e AstrofisicaAngular resolutionbusinessArgoRemote sensing
researchProduct

Indirect estimation of calibration equation parameters for Sentek Diviner 2000 capacitance probe by means of soil physical properties

2014

Measurements of soil water content (SWC) are often used for irrigation scheduling. Accurate monitoring of SWC is necessary, for example, to identify the exact irrigation timing and the amount of water volume to supply according to the crop requirement. The use of capacitance probes, measuring the apparent soil dielectric permittivity, indirectly related to soil water status, have been increasing during the last decade, as proved by the numerous researches carried out to determine, for different soil types, site-specific calibration relationships between SWC and the scaled frequency (SF) measured by the sensor. However, for swelling/shrinking clay soils, there is a lack of knowledge on how t…

Settore AGR/03 - Arboricoltura Generale E Coltivazioni ArboreeFDR soil moisture sensors Diviner 2000 CalibrazioneSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-Forestali
researchProduct

Integrazione della rete tramviaria nel sistema dei trasporti della città di Palermo

2008

Settore ICAR/05 - TrasportiCalibrazione Modelli di domanda
researchProduct

Procedura di calibrazione di un set di Dosimetri TLD secondo la ISO/ASTM51956:2005(E) e la ASTM standard E-668

2016

La misura della dose assorbita da dosimetri passivi, a seguito della loro esposizione a radiazioni ionizzanti, è una procedura fondamentale per valutare gli effetti indotti da tali radiazioni nell’ambito della dosimetria ambientale. Per effettuare delle corrette valutazioni, è stato selezionato un set di dosimetri a termoluminescenza (TLD) scelti, tra un’ampia gamma di tipologie di dosimetri a nostra disposizione, come i più idonei a fornire misure di dose attendibili (nelle prescritte condizioni di funzionamento). Tali dosimetri sono stati sottoposti ad una specifica procedura di irraggiamento e successiva lettura, allo scopo di realizzare un’opportuna calibrazione nel rispetto di quanto p…

Settore ING-IND/20 - Misure E Strumentazione NucleariDosimetri TLD ASTM E -668 calibrazione
researchProduct

Procedura di calibrazione di sistemi dosimetrici a film radio-cromici GAFCHROMIC® mod. HD-V2

2016

I sistemi dosimetrici a film radiocromici vengono utilizzati nelle misure della dose assorbita da vari materiali sottoposti a radiazioni ionizzanti, nei quali avvengono reazioni chimiche che intensificano le bande ottiche d’assorbanza determinata, quest’ultima, tramite l’utilizzo di uno spettrofotometro. L’impiego di questi sistemi comporta una preliminare calibrazione degli stessi in riferimento a standard internazionali. La dose rilevata fa riferimento generalmente alla dose assorbita in acqua anche se è possibile determinare la stessa in altri materiali tramite opportuni fattori correttivi. L’interesse verso questi sistemi dosimetrici è relativo all’impiego in processi industriali d’irra…

Settore ING-IND/20 - Misure E Strumentazione Nuclearidosimetri radiocromici calibrazione
researchProduct

IMPIEGO DEL RADIONUCLIDE 137CS PER LA STIMA DEI PROCESSI EROSIVI IN UN BACINO FORESTATO

2008

Il radionuclide cesio-137 (137Cs) è uno dei traccianti più utilizzati per stimare la perdita di suolo per erosione idrica. L'applicazione di questa tecnica alla scala di bacino richiede anzitutto l'acquisizione delle misure del radionuclide in punti distribuiti sulla superficie e l'utilizzo di modelli di conversione idonei a trasformare i valori di 137Cs in quantità di erosione netta o di deposito. La presente memoria si pone l'obiettivo di verificare l'affidabilità del modello di conversione esponenziale per stimare i processi erosivi in terreni interessati da coperture forestali. L'applicazione è stata condotta in un bacino sperimentale della Sila Greca per il quale sono disponibili alcun…

cesio 137erosione del suolo produzione di sedimenti bacini forestatiSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-Forestalierosione nettacalibrazione modello
researchProduct

Riduzione ottimale dell’eterogeneita’ per la calibrazione dei modelli di reti idriche

2002

reti idriche calibrazione
researchProduct

Calibrazione dei parametri di qualità nelle reti di approvvigionamento idrico e caratterizzazione della diversità spaziale – applicazione ad un caso …

2007

reti idriche calibrazione simulatione
researchProduct