Search results for "Capillary action"
showing 10 items of 179 documents
New Tools for Characterizing Metallic Nanoparticles: AgNPs, A Case Study.
2015
Currently, transmission electron microscopy (TEM) is the main technique for estimating the sizes of spherical nanoparticles (NPs) and through them, their concentrations. This paper demonstrates for the first time that C18 reversed-phase capillary liquid chromatography (Cap-LC) coupled to diode array detection (DAD) has the potential to estimate mean concentrations of silver nanoparticles (AgNPs) and thereby determine their average size. Direct injection of the sample without previous extraction or separation steps is carried out. Only a unique standard with a known AgNP size is needed for the calibration. In a first approach, the new method has been tested over silver nanoparticles, produce…
Capillary Hysteresis in Nanopores: Theoretical and Experimental Studies of Nitrogen Adsorption on MCM-41
1995
Capillary hysteresis in cylindrical nanopores has been studied using MCM-41 as the prime example of a mesoporous material. These materials, due to their regular pore structure, can be considered to be candidates for reference adsorbents for standardizing adsorption measurements and methods for characterization of porous solids. They provide a unique opportunity for verification of theoretical models employed for predicting phase equilibrium in confined geometry. Three samples with monodisperse pore channels have been synthesized and examined using X-ray diffraction (XRD). Nitrogen adsorption isotherms were modeled using nonlocal density functional theory (NLDFT) in a wide range of pore size…
Geometric Considerations in Modeling Oxygen Transport Processes in Tissue
1973
Numerical solution of partial differential equations describing transport processes in capillaries and tissue is used for calculation of oxygen transport to brain tissue. Calculation is based on a three-dimensional network model which covers inhomogeneities in capillary blood flow in a relation of 27:1, This study was performed in order to obtain information about the influence of the main physiological parameters on oxygen tension frequency distribution pattern. Following results were obtained: a)Increase (or decrease) of the oxygen consumption rate in tissue to about twice (or half) of the normal case for cerebral grey matter causes an extreme left (or right) shift of the oxygen tension f…
A vacuum cell for obtaining clean surfaces on liquid low melting point metals
1997
Abstract Clean oxide film-free surface of liquid gallium was obtained in a sealed vacuum cell with a glass lid for observation. The cell was evacuated to high vacuum (10 -4 Pa) before admission of liquid and sealing. The surface contamination was about 2–5% of the free area and did not exhibit noticeable increase during several months of storing and employing the cell. The cell described allows observation of surface flows, capillary phenomena and crystallization processes under different conditions.
Determination of the Stability Constants of the Acetate Complexes of the Actinides Am(III), Th(IV), Np(V), and U(VI) Using Capillary Electrophoresis-…
2019
Capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS) was used to determine the stability constants of the actinides Am(III), Th(IV), Np(V), and U(VI) at an ionic strength of I = 0.3 M. The obtained stability constants were extrapolated to zero ionic strength by means of the Davies equation. For both U(VI) and Am(III), three consecutive acetate complexes with log(β
A new ionic liquid dimethyldinonylammonium bromide as a flow modifier for the simultaneous determination of eight carboxylates by capillary electroph…
2005
Two new methods of capillary zone electrophoresis based on aqueous phosphate running buffers with UV spectrophotometric detection were developed and optimized for the determination of eight carboxylates as copper complexes. Metalcomplexes are negatively charged, so measurements were made as anion analyses with flow reversal in the capillary. Two flow modifiers were used: a common tetradecyltrimethylammonium bromide (TTAB) and a new ionic liquid dimethyldinonylammonium bromide (DMDNAB). The methods were compared to each other. Better separation was achieved with DMDNAB as the flow modifier. Method development was done using a fused silica capillary (61 cm x 50 microm i.d.). Optimization was …
Gas-liquid chromatographic analyses
1985
Glass capillary gas chromatography of chlorinated methyl acetates, propanoates and butanoates on Carbowax 20M and SE-30 columns
1982
The gas chromatography of all chlorinated methyl acetates, methyl propanoates and methyl mono- and dichlorobutanoates has been studied on Carbowax 20M and SE-30 glass capillary columns under various running conditions. The order of elution on a non-polar column was largely determined by the boiling point of esters, whereas on a polar column it was much influenced by the structure of compounds. Complete separation of the combined mixture of all 27 compounds could not be achieved, however, methyl 3,3-dichlorobutanoate was the only ester overlapped on both columns in spite of the various column temperatures used. The best separation of the mixture was on Carbowax 20M with a temperature program…
Synchronized gradient elution in capillary liquid chromatography
2013
Abstract The synchronization of injection valve operation and gradient elution in capillary liquid chromatography (cHPLC) is studied. Focus is placed on the cHPLC systems which rely on the splitting of a primary flow to provide the much smaller secondary flow required at the injection device and analytical column. Owing to the tiny secondary flow rates, synchronization is necessary to achieve proper optimization of gradient elution methods. Otherwise, there is a risk of having the analytes totally or partially eluted in the initial isocratic conditions, and there is no control on the actual gradient profile reaching the column. Synchronization is first achieved by switching back the valve t…
On-line Chloride Interference Removal for Arsenic Determination in Waste Water and Urine by ICP-MS Using a Modified Capillary
2002
The determination of arsenic in environmental samples like waste waters from industrial effluents and in biological samples like urine is very important due to the toxic nature of some of its species at moderate levels of exposure. The objective of this study was to evaluate the capability of modified anionic capillaries to remove chloride for ICP-MS determination of arsenic, which causes spectral interference due to formation of 40 Ar 35 Cl + . Also high chloride content gives non-spectral interferences. The results indicate that arsenic at a concentration higher than 1 µg L m 1 in a matrix with a chloride content up to 600 mg L m 1 can be accurately determined using a 3-aminopropyltrimeth…