Search results for "Capillary action"

showing 10 items of 179 documents

New Tools for Characterizing Metallic Nanoparticles: AgNPs, A Case Study.

2015

Currently, transmission electron microscopy (TEM) is the main technique for estimating the sizes of spherical nanoparticles (NPs) and through them, their concentrations. This paper demonstrates for the first time that C18 reversed-phase capillary liquid chromatography (Cap-LC) coupled to diode array detection (DAD) has the potential to estimate mean concentrations of silver nanoparticles (AgNPs) and thereby determine their average size. Direct injection of the sample without previous extraction or separation steps is carried out. Only a unique standard with a known AgNP size is needed for the calibration. In a first approach, the new method has been tested over silver nanoparticles, produce…

ChemistryCapillary action010401 analytical chemistryExtraction (chemistry)Analytical chemistryNanoparticle02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesDiode arraySilver nanoparticle0104 chemical sciencesAnalytical ChemistryTransmission electron microscopyCalibration0210 nano-technologyMetal nanoparticlesAnalytical chemistry
researchProduct

Capillary Hysteresis in Nanopores: Theoretical and Experimental Studies of Nitrogen Adsorption on MCM-41

1995

Capillary hysteresis in cylindrical nanopores has been studied using MCM-41 as the prime example of a mesoporous material. These materials, due to their regular pore structure, can be considered to be candidates for reference adsorbents for standardizing adsorption measurements and methods for characterization of porous solids. They provide a unique opportunity for verification of theoretical models employed for predicting phase equilibrium in confined geometry. Three samples with monodisperse pore channels have been synthesized and examined using X-ray diffraction (XRD). Nitrogen adsorption isotherms were modeled using nonlocal density functional theory (NLDFT) in a wide range of pore size…

ChemistryCapillary actionDispersityMineralogyThermodynamicsSurfaces and InterfacesCondensed Matter PhysicsCondensed Matter::Materials ScienceNanoporeHysteresisAdsorptionMetastabilityElectrochemistryGeneral Materials ScienceDensity functional theoryMesoporous materialSpectroscopyLangmuir
researchProduct

Geometric Considerations in Modeling Oxygen Transport Processes in Tissue

1973

Numerical solution of partial differential equations describing transport processes in capillaries and tissue is used for calculation of oxygen transport to brain tissue. Calculation is based on a three-dimensional network model which covers inhomogeneities in capillary blood flow in a relation of 27:1, This study was performed in order to obtain information about the influence of the main physiological parameters on oxygen tension frequency distribution pattern. Following results were obtained: a)Increase (or decrease) of the oxygen consumption rate in tissue to about twice (or half) of the normal case for cerebral grey matter causes an extreme left (or right) shift of the oxygen tension f…

ChemistryCapillary actionLeft shiftOxygen transportmedicinechemistry.chemical_elementBlood flowmedicine.diseaseRight shiftOxygenNormal caseBiomedical engineeringOxygen tension
researchProduct

A vacuum cell for obtaining clean surfaces on liquid low melting point metals

1997

Abstract Clean oxide film-free surface of liquid gallium was obtained in a sealed vacuum cell with a glass lid for observation. The cell was evacuated to high vacuum (10 -4 Pa) before admission of liquid and sealing. The surface contamination was about 2–5% of the free area and did not exhibit noticeable increase during several months of storing and employing the cell. The cell described allows observation of surface flows, capillary phenomena and crystallization processes under different conditions.

ChemistryCapillary actionbusiness.industryUltra-high vacuumOxideLow melting pointContaminationCondensed Matter PhysicsSurfaces Coatings and Filmslaw.inventionchemistry.chemical_compoundOpticsChemical engineeringlawCrystallizationLiquid galliumbusinessInstrumentationVacuum
researchProduct

Determination of the Stability Constants of the Acetate Complexes of the Actinides Am(III), Th(IV), Np(V), and U(VI) Using Capillary Electrophoresis-…

2019

Capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS) was used to determine the stability constants of the actinides Am(III), Th(IV), Np(V), and U(VI) at an ionic strength of I = 0.3 M. The obtained stability constants were extrapolated to zero ionic strength by means of the Davies equation. For both U(VI) and Am(III), three consecutive acetate complexes with log(β

Chromatography010405 organic chemistryChemistryCapillary actionIonic bondingActinidePlasma010402 general chemistryMass spectrometry01 natural sciences0104 chemical sciencesInorganic ChemistryCapillary electrophoresisPhysical and Theoretical ChemistryInductively coupled plasma mass spectrometryInorganic chemistry
researchProduct

A new ionic liquid dimethyldinonylammonium bromide as a flow modifier for the simultaneous determination of eight carboxylates by capillary electroph…

2005

Two new methods of capillary zone electrophoresis based on aqueous phosphate running buffers with UV spectrophotometric detection were developed and optimized for the determination of eight carboxylates as copper complexes. Metalcomplexes are negatively charged, so measurements were made as anion analyses with flow reversal in the capillary. Two flow modifiers were used: a common tetradecyltrimethylammonium bromide (TTAB) and a new ionic liquid dimethyldinonylammonium bromide (DMDNAB). The methods were compared to each other. Better separation was achieved with DMDNAB as the flow modifier. Method development was done using a fused silica capillary (61 cm x 50 microm i.d.). Optimization was …

ChromatographyAqueous solutionmedicine.diagnostic_testCapillary actionOrganic ChemistryAnalytical chemistryCarboxylic Acidschemistry.chemical_elementElectrophoresis CapillaryGeneral MedicineBiochemistryCopperTrimethyl Ammonium CompoundsAnalytical ChemistryQuaternary Ammonium Compoundschemistry.chemical_compoundElectrophoresisCapillary electrophoresischemistrySpectrophotometryIonic liquidmedicineSpectrophotometry UltravioletCarboxylateWater Pollutants ChemicalJournal of chromatography. A
researchProduct

Gas-liquid chromatographic analyses

1985

ChromatographyCapillary actionChemistryOrganic ChemistryOrganic chemistryGeneral MedicineBiochemistryGas liquid chromatographicAnalytical ChemistryJournal of Chromatography A
researchProduct

Glass capillary gas chromatography of chlorinated methyl acetates, propanoates and butanoates on Carbowax 20M and SE-30 columns

1982

The gas chromatography of all chlorinated methyl acetates, methyl propanoates and methyl mono- and dichlorobutanoates has been studied on Carbowax 20M and SE-30 glass capillary columns under various running conditions. The order of elution on a non-polar column was largely determined by the boiling point of esters, whereas on a polar column it was much influenced by the structure of compounds. Complete separation of the combined mixture of all 27 compounds could not be achieved, however, methyl 3,3-dichlorobutanoate was the only ester overlapped on both columns in spite of the various column temperatures used. The best separation of the mixture was on Carbowax 20M with a temperature program…

ChromatographyCapillary actionElutionChemistryOrganic ChemistryClinical BiochemistryAnalytical chemistryBiochemistryIsothermal processCapillary gas chromatographyAnalytical ChemistryBoiling pointPolarGas chromatographyChromatography columnChromatographia
researchProduct

Synchronized gradient elution in capillary liquid chromatography

2013

Abstract The synchronization of injection valve operation and gradient elution in capillary liquid chromatography (cHPLC) is studied. Focus is placed on the cHPLC systems which rely on the splitting of a primary flow to provide the much smaller secondary flow required at the injection device and analytical column. Owing to the tiny secondary flow rates, synchronization is necessary to achieve proper optimization of gradient elution methods. Otherwise, there is a risk of having the analytes totally or partially eluted in the initial isocratic conditions, and there is no control on the actual gradient profile reaching the column. Synchronization is first achieved by switching back the valve t…

ChromatographyCapillary actionElutionChemistryOrganic ChemistryMixing (process engineering)Analytical chemistryBenzeneGeneral MedicineInjectorSecondary flowBiochemistryAnalytical Chemistrylaw.inventionSynchronization (alternating current)Volume (thermodynamics)lawSpark plugChromatography High Pressure LiquidJournal of Chromatography A
researchProduct

On-line Chloride Interference Removal for Arsenic Determination in Waste Water and Urine by ICP-MS Using a Modified Capillary

2002

The determination of arsenic in environmental samples like waste waters from industrial effluents and in biological samples like urine is very important due to the toxic nature of some of its species at moderate levels of exposure. The objective of this study was to evaluate the capability of modified anionic capillaries to remove chloride for ICP-MS determination of arsenic, which causes spectral interference due to formation of 40 Ar 35 Cl + . Also high chloride content gives non-spectral interferences. The results indicate that arsenic at a concentration higher than 1 µg L m 1 in a matrix with a chloride content up to 600 mg L m 1 can be accurately determined using a 3-aminopropyltrimeth…

ChromatographyCapillary actionHealth Toxicology and MutagenesisPublic Health Environmental and Occupational HealthSoil Sciencechemistry.chemical_elementUrinePollutionChlorideAnalytical ChemistryMatrix (chemical analysis)chemistryWastewatermedicineEnvironmental ChemistryWaste Management and DisposalEffluentInductively coupled plasma mass spectrometryArsenicWater Science and Technologymedicine.drugInternational Journal of Environmental Analytical Chemistry
researchProduct