Search results for "Cardiac Catheterization"
showing 10 items of 69 documents
Effects of the coronavirus disease 2019 pandemic on the number of hospitalizations for myocardial infarction: regional differences. Population analys…
2020
Spontaneous echo contrast caused by platelet and leukocyte aggregates?
2001
Background and Purpose —Spontaneous echocardiographic contrast (SEC) is correlated to clinical thromboembolic events. We sought to determine the origin of SEC by utilizing direct analysis of left atrial blood. Methods —We examined the blood of 13 patients with and 19 without SEC. Blood samples were taken from the femoral vein and artery and from the right and left atria after transseptal puncture. Samples were incubated with fluorescence-labeled antibodies directed against the platelet (CD41a-PE, CD42b-PE, and CD62p-FITC) and leukocyte membrane epitopes (CD45-APC and CD14-FITC). The expressed epitopes were analyzed by dual laser flow cytometry immediately after blood withdrawal. Results —I…
Cardiac MR enables diagnosis in 90% of patients with acute chest pain, elevated biomarkers and unobstructed coronary arteries
2015
To assess the diagnostic value of cardiac MRI (CMR) in patients with acute chest pain, elevated cardiac enzymes and a negative coronary angiogram.This study included a total of 125 patients treated in the chest pain unit during a 39-month period. Each included patient underwent MRI within a median of 3 days after cardiac catheterization. The MRI protocol comprised cine, oedema-sensitive and late gadolinium-enhancement imaging. The standard of reference was a consensus diagnosis based on clinical follow-up and the synopsis of all clinical, laboratory and imaging data.MRI revealed a multitude of diagnoses, including ischaemic cardiomyopathy (CM), dilated CM, myocarditis, Takotsubo CM, hyperte…
Circulatory response to volume expansion and transjugular intrahepatic portosystemic shunt in refractory ascites: Relationship with diastolic dysfunc…
2015
Abstract Background Cirrhotic cardiomyopathy may lead to heart failure in stressful circumstances, such as after transjugular intrahepatic portosystemic shunt (TIPS) placement. Aim To examine whether acute volume expansion predicts haemodynamic changes after TIPS and elicits signs of impending heart failure. Methods We prospectively evaluated refractory ascites patients (group A) and compensated cirrhotics (group B), who underwent echocardiography, NT-proBNP measurement, and heart catheterization before and after volume load; group A repeated measurements after TIPS. Results 15 patients in group A (80% male; 54 ± 12.4 years) and 8 in group B (100% male; 56 ± 6.2 years) were enrolled. Echoca…
Vulnerability of the right ventricle to cathodal, anodal, and bipolar stimulation at double diastolic threshold strength
1984
The repetitive ventricular response (RVR) to three stimulation techniques (bipolar, cathodal and anodal) was investigated in 35 patients. 26 patients suffered from coronary heart disease and 9 patients from dilative cardiomyopathy. The stimulation study was performed at a ventricular driving rate of 120/min with one and two premature ventricular extrastimuli. We used rectangular impulses of 1.8 ms duration at duable diastolic threshold strength. RVR was scored as follows: 0: no RVR, 1: one nonstimulated RVR, 2: two nonstimulated RVR, 3: three nonstimulated RVR, 4: four to ten nonstimulated RVR, 5: more than ten nonstimulated RVR lasting less than 2 minutes, 6: sustained ventricular tachycar…
Clinical application of a new rheolytic thrombectomy catheter system for massive pulmonary embolism
1999
Quantitative assessment of aortic stenosis by three-dimensional echocardiography
1997
The purpose of this study was to assess the feasibility of three-dimensional echocardiography in aortic stenosis. Planimetric determination of valve area and dynamic volume-rendered display were performed. Three-dimensional echocardiography permits display of any desired plane of the cardiac structure. Thus in the case of aortic stenosis, the plane used for planimetric evaluation can be positioned exactly through the valve orifice. Dynamic volume-rendered display may provide a spatial demonstration of the stenotic valve. In 48 patients aortic valve area was measured by planimetry. The three-dimensional data set was acquired by a workstation in the course of a multiplane transesophageal exam…
Contrast echocardiography of the left ventricle an independent predictor of pulmonary artery pressure?
1994
To test the hypothesis that left heart opacification is dependent on pulmonary artery pressure, we analyzed consecutively 12 patients with normal and 8 patients with abnormal pulmonary artery pressure with a new lung capillary stable echo contrast agent. Patients underwent contrast echocardiographic examination within 6 hours before right and left heart catheterization with 200 mg/ml and 400 mg/ml SHU 508A intravenously. The mean pulmonary artery pressure was 15.4 mmHg in the patients with normal pulmonary artery pressures and 46.4 mmHg in the patients with pulmonary hypertension (p0.000). Echocardiograms were video-intensitometrically analyzed for intensity maximum (MAX), half-time of vide…
Noninvasive assessment of pulmonary hemodynamics in patients with chronic thromboembolic pulmonary hypertension by high temporal resolution phase-con…
2013
Background— Right heart catheterization is the gold standard for assessment of pulmonary hemodynamics in patients with chronic thromboembolic pulmonary hypertension. To date, MRI has not been able to produce precise measurements of mean pulmonary arterial pressure (mPAP). The purpose of the study was to create a model for estimating mPAP and pulmonary vascular resistance in patients with chronic thromboembolic pulmonary hypertension by high temporal resolution phase-contrast MRI (PC-MRI) and to correlate the results with simultaneously acquired, invasive catheter-based measurements (simultaneously measured mPAP) and with right heart catheterization measurements. Methods and Results— A tota…
Parametric assessment of myocardial perfusion during interventional cardiac catheterization by means of X-ray densitometry-short-and long-term result…
1990
X-ray densitometric evaluation of digital subtraction angiocardiograms allows an assessment of myocardial perfusion by means of the parameter 'MEAN RISE TIME' (MRT), defined as the time from the onset of local myocardial contrast medium opacification to the point of maximum opacification. Best results are obtained when the response of that parameter is compared before and after stimulation of coronary flow by papaverine. A prolongation of this parameter, especially after papaverine, was indicative of an impairment of myocardial perfusion, when compared to the results of TL-201 scintigraphy. In 50 patients with single vessel coronary artery disease the results of MRT pre and post papaverine …