Stem cells and new intervention measures as emerging therapy in cardiac surgery
2020
Cardiovascular disease (CVD) presents a great burden for elderly patients, their caregivers, and health systems. Structural and functional alterations of vessels accumulate throughout life, culminating in increased risk of developing CVD. Several inflammatory pathway are involved in vascular ageing. The growing elderly population worldwide highlights the need to understand how aging promotes CVD in order to develop new strategies to confront this challenge. In this review we analyzed the role of stem cells and new intervention measures as emerging drugs for vascular aging.Choroby układu krążenia (CVD) są ogromnym obciążeniem dla osób w podeszłym wieku i ich opiekunów, a także systemów opiek…
Endocrine Challenges in Patients with Continuous-Flow Left Ventricular Assist Devices
2021
Heart failure (HF) remains a leading cause of morbidity, hospitalization, and mortality worldwide. Advancement of mechanical circulatory support technology has led to the use of continuous-flow left ventricular assist devices (LVADs), reducing hospitalizations, and improving quality of life and outcomes in advanced HF. Recent studies have highlighted how metabolic and endocrine dysfunction may be a consequence of, or associated with, HF, and may represent a novel (still neglected) therapeutic target in the treatment of HF. On the other hand, it is not clear whether LVAD support, may impact the outcome by also improving organ perfusion as well as improving the neuro-hormonal state of the pat…
Flußquantifizierung von intrakardialen Shuntvolumina unter Verwendung der MR-Phasenkontrast-Technik in Atemanhaltephase
1998
PURPOSE Comparison of a breath-hold, velocity-encoded, phase-difference magnetic resonance (MR) sequence for intracardiac shunt flow measurement with the invasive shunt size determination by oximetry. PATIENTS AND METHODS 10 patients with different cardiac shunts (6 ASD/3 VSD/1 PDA) and four healthy individuals were investigated using a 1.5 Tesla Siemens Vision system. For flow measurements a breath-hold, velocity-encoded, phase-difference magnetic resonance (MR) sequence was used ('through plane', FLASH 2D-sequence, TR/TE 110/5 ms, 'velocity encoding' 250 cm/s). Mean flow (ml/R-R interval) in the ascending aorta, the pulmonary trunk, and the right and left pulmonary arteries was determined…
Proteolytic capacity in mouse cardiac muscle following strenuous exercise
1981
Proteolytic capacity in mouse cardiac muscle was analyzed 1, 3, and 6 days after exhaustive intermittent or submaximal prolonged running. No significant changes were recorded in the activities of acid or alkaline proteases, β-glucuronidase or trypsin inhibitor. Similarly, no changes were found in the rates of acid or neutral autolysis.
KCND3 is a novel susceptibility locus for early repolarization
2019
AbstractThe presence of an early repolarization pattern (ERP) on the surface electrocardiogram (ECG) is associated with risk of ventricular fibrillation and sudden cardiac death. Family studies have shown that ERP is a highly heritable trait but molecular genetic determinants are unknown. We assessed the ERP in 12-lead ECGs of 39,456 individuals and conducted a two-stage meta-analysis of genome-wide association studies (GWAS). In the discovery phase, we included 2,181 cases and 23,641 controls from eight European ancestry studies and identified 19 genome-wide significant (p<5E-8) variants in the KCND3 (potassium voltage gated channel subfamily D member 3) gene with a p-value of 4.6E-10. …
Comparison of Arterial and Venous Blood Flow Between Patients with Pressure Dressing or a New Hemostatic Puncture Closure Device After Cardiac Cathet…
1997
The aim of the study was to compare arterial and venous flow volume in the punctured leg in patients given a conventional pressure dressing and those given a new hemostatic puncture closure device (Angio-Seal) after cardiac catheterization. We prospectively measured blood flow in 25 patients with pressure dressing (group A) and 25 patients with Angio-Seal (group B) after cardiac catheterization. Duplex sonographic measurements were performed at the superficial femoral artery and vein of the punctured leg. In group A measurements were performed before catheterization, during pressure dressing, and after removal of pressure dressing. In group B we performed the measurements before catheteriza…
Antiapoptotic effect of calcitonin gene-related peptide on oxidative stress-induced injury in H9c2 cardiomyocytes via the RAMP1/CRLR complex.
2005
Calcitonin gene-related peptide (CGRP) plays an important role in the mediation of protective effects observed in situations such as ischemic preconditioning in rat hearts. In this study, we investigated in H9c2 rat cardiomyoblasts if the protective effect of CGRP could be linked to an inhibitory effect on the apoptotic pathway. We also determined the specificity of observed effects by treatment with adrenomedullin (ADM) in stress conditions generated by 100 microM hydrogen peroxide. Using MTT assays, we demonstrate that a pretreatment with CGRP decreases by half the loss of cell viability induced by H(2)O(2). CGRP inhibits phosphatidylserine externalization, caspase 3 activation and DNA fr…
Effects of canagliflozin on serum potassium in people with diabetes and chronic kidney disease: the CREDENCE trial
2021
Abstract Aims Hyperkalaemia is a common complication of type 2 diabetes mellitus (T2DM) and limits the optimal use of agents that block the renin–angiotensin–aldosterone system, particularly in patients with chronic kidney disease (CKD). In patients with CKD, sodium‒glucose cotransporter 2 (SGLT2) inhibitors provide cardiorenal protection, but whether they affect the risk of hyperkalaemia remains uncertain. Methods and results The CREDENCE trial randomized 4401 participants with T2DM and CKD to the SGLT2 inhibitor canagliflozin or matching placebo. In this post hoc analysis using an intention-to-treat approach, we assessed the effect of canagliflozin on a composite outcome of time to eith…
Requirements on resolution of digital imaging equipment in the cardiac catheterization laboratory.
1988
We evaluated the requirements on spatial resolution of digital imaging equipment in the cardiac catheterization laboratory. Fifty cinefilms of the heart as the biological object and one film of a lead-ladder-pattern as an objective test were used. The patient films were examined for the visibility of the left ventricular angiogram, coronary arterial tree, coronary artery lesions, branching of septal arteries and the number of septal arteries. All films were viewed three times: with a 625 line TV-system, with a 1249 line TV-system and with a cineprojector. It was found that two application areas with different demands on the spatial and temporal resolution can be distinguished: 1) low spatia…
Advanced Protocol for Three-Dimensional Transesophageal Echocardiography Guidance Implementing Real-Time Multiplanar Reconstruction for Transcatheter…
2019
Transcatheter direct annuloplasty has been introduced as a novel interventional treatment option for severe mitral valve regurgitation. Until now, only one direct annuloplasty device (Edwards Cardioband) has been commercially available, being implanted in more than 250 patients worldwide. Yet this procedure poses greater challenges regarding optimal fluoroscopic and echocardiographic guidance compared with edge-to-edge repair: correct localization and orientation of the anchors upon penetration into the fibrous mitral annulus tissue and the basal left ventricular myocardium are preconditions for an optimal result and essential to avoid damage of the neighboring structures (atrioventricular …