Search results for "Cataract Extraction"

showing 10 items of 33 documents

Visual Acuity and Contrast Sensitivity in Eyes Implanted with Aspheric and Spherical Intraocular Lenses

2009

Purpose To compare visual acuity and contrast sensitivity (CS) in eyes implanted with aspheric and spherical intraocular lenses (IOLs) after cataract surgery. Design Randomized, prospective study. Participants Five hundred twenty-four eyes from 262 cataract surgery patients implanted with 2 IOL models: the AcrySof IQ (262 eyes) and AcrySof SN60AT (262 eyes; Alcon Laboratories, Fort Worth, TX). Methods High-contrast photopic best-corrected distance visual acuity (BCVA) and CS under photopic (85 cd/m 2 ) and mesopic (6 cd/m 2 ) conditions were measured. Pupil diameter was analyzed for distance vision under both lighting conditions. Follow-up was carried out for 6 months in all patients. Main …

Malemedicine.medical_specialtyVisual acuityLightPseudophakiagenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityDark AdaptationIntraocular lensCataract ExtractionProsthesis DesignContrast SensitivityLens Implantation IntraocularVision MonocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonLenses Intraocularbusiness.industryPupilCataract surgeryeye diseasesOphthalmologyAlcon LaboratoriesIntraocular lensesOptometryFemalesense organsmedicine.symptombusinessPhotopic visionOphthalmology
researchProduct

Axial Elongation following Cataract Surgery during the First Year of Life in the Infant Aphakia Treatment Study

2012

PURPOSE To compare ocular axial elongation in infants after unilateral cataract surgery corrected with a contact lens (CL) or primary intraocular lens (IOL) implantation. METHODS Baseline axial length (AL) was measured at the time of cataract surgery (1-6 months) and at age 1 year. AL at baseline and age 1 year and the change in length/mo were analyzed in relation to treatment modality, cataractous versus fellow eye, and age at surgery using linear mixed models. RESULTS Mean baseline AL did not differ between the CL and IOL groups for either cataractous or fellow eyes. Eyes with cataracts were shorter than fellow eyes by an average of 0.6 mm (95% confidence interval [CI], 0.4-0.8 mm; P < 0.…

Malemedicine.medical_specialtyVisual acuitygenetic structuresContact Lensesmedicine.medical_treatmentVisual AcuityIntraocular lensFirst year of lifeAphakia PostcataractCataract ExtractionAphakiaCataractCataractsOphthalmologymedicineHumansPostoperative PeriodLenses Intraocularbusiness.industryInfant NewbornInfantArticlesCataract surgerymedicine.diseaseRefractive ErrorsAxial elongationeye diseasesSurgeryContact lensTreatment OutcomeFemalesense organsmedicine.symptombusinessFollow-Up Studies
researchProduct

Efficacy and Safety of Mass Cataract Surgery Campaign in a Developing Country

2012

To determine the visual outcomes achieved in terms of efficacy and safety during a mass eye surgery campaign in a low-income developing country.Three hundred fifteen eyes of 305 patients underwent extracapsular cataract extraction with intraocular lens implantation in a prospective, analytical, experimental, and nonrandomized study on patients who underwent cataract surgery during the campaign that two Spanish nongovernmental organizations conducted in December 2008 in a district hospital in Bobo-Dioulasso (Burkina Faso).Mean age was 61.97 ± 14.39 years. The mean uncorrected distance visual acuity before surgery was 2.17 ± 0.7 (20/3000), which improved to 0.86 ± 0.64 logMAR (20/150) 3 month…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityDeveloping countryIntraocular lensCataract ExtractionCataractCataract extractionLens Implantation IntraocularBurkina FasomedicineHumansProspective StudiesEye surgeryProspective cohort studyDeveloping Countriesbusiness.industryFollow up studiesMiddle AgedCataract surgeryeye diseasesSurgeryOphthalmologyTreatment OutcomeFemalesense organsmedicine.symptombusinessFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Visual outcomes and complications of congenital cataract surgery

2019

Corresponding author at: Department of Ophthalmology, 14, rue Paul-Gaffarel, 21000 Dijon, France. This work is issued from the oral presentation during the 123rd congress of the French Ophthalmological Society.; International audience; PURPOSE: To describe the visual results and postoperative complications of congenital cataract surgeries performed between 2005 and 2016. METHODS: A retrospective consecutive case series of congenital cataract surgeries was carried out at the Dijon University Hospital in France. Intraocular lens implantation was primary or secondary according to age. Pre- and post-operative assessment was performed through ophthalmologic consultations with orthoptic measureme…

Malemedicine.medical_specialtyVisual acuitygenetic structuresvisual acuitymedicine.medical_treatmentintraocular lensIntraocular lensCataract ExtractionCataract03 medical and health sciences0302 clinical medicineLens Implantation IntraocularCataractsInterquartile rangepostoperative complicationsHumansMedicine[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrgansRetrospective StudiesLenses Intraocularbusiness.industryInfantPostoperative complicationConsecutive case seriesCataract surgerymedicine.diseaseeye diseases3. Good healthSurgeryBilateral CataractsOphthalmologyTreatment Outcomecongenital cataractChild Preschool030221 ophthalmology & optometryFemaleFrancesense organsmedicine.symptombusiness[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
researchProduct

Factors influencing myopic shift in children after intraocular lens implantation.

2019

Introduction:Intraocular lenses have always been a controversial topic in pediatric cataract surgery. In the early 1990s in the post-Soviet states of Eastern Europe, intraocular lenses promised an easier full-time correction and amblyopia treatment. Since 1991, ophthalmologists in Latvia have been implanting intraocular lenses in infants. Amount of the postoperative myopic shift and its influencing factors, analyzed in this article, are important indicators of congenital cataract treatment.Materials and methods:A retrospective chart review off 85 children (137 eyes) who underwent foldable posterior chamber intraocular lens implantation at the Clinical University Hospital in Riga, Latvia, fr…

Malemedicine.medical_specialtygenetic structuresAdolescentmedicine.medical_treatmentVisual AcuityIntraocular lensCataract ExtractionAmblyopiaRefraction OcularCataractLens Implantation IntraocularOphthalmologymedicineMyopiaHumansChildRetrospective StudiesLenses Intraocularbusiness.industryVision TestsInfantGeneral Medicineeye diseasesOphthalmologyIntraocular lensesChild PreschoolFemalesense organsbusinessPediatric cataractEuropean journal of ophthalmology
researchProduct

Prevention of hyperopic surprise after LASIK in patients with refractive multifocal intraocular lenses.

2011

Purpose. Three cases of patients who developed a similar hyperopic defect in refraction following laser in situ keratomileusis (LASIK) after multifocal intraocular lens (IOL) implantation are described. Methods. Ophthalmologic evaluation including refractive status, corrected and uncorrected visual acuity (both at far and near), and corneal topography in patients presenting similar hyperopic refractive surprise in one eye as a result of LASIK refinement of residual ametropia after refractive multifocal IOL implantation. Results. Laser in situ keratomileusis enhancement for residual ametropia of −1.00 to −1.50 D in patients with a prior implantation of refractive multifocal IOL resulted in a…

Malemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisCataract ExtractionRefraction OcularBioptics (surgery)Lens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses Intraocularmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyGeneral MedicineMultifocal intraocular lensMiddle AgedCorneal topographySubjective refractionRefractioneye diseasesOphthalmologyHyperopiaFemalesense organsbusinessEuropean journal of ophthalmology
researchProduct

In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens.

2015

Purpose To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Finevision full diffractive trifocal IOL. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of lig…

Optics and PhotonicsOptical PhenomenaComputer sciencemedicine.medical_treatmentCataract ExtractionProsthesis DesignRefraction Ocular03 medical and health sciencesNear vision0302 clinical medicineLens Implantation IntraocularOptical transfer functionmedicineProsthesis designHumansLenses IntraocularStrehl ratioCataract surgeryMultifocal intraocular lensModels TheoreticalSensory SystemsOptical qualityOphthalmologyIntraocular lenses030221 ophthalmology & optometryOptometrySurgery030217 neurology & neurosurgeryJournal of cataract and refractive surgery
researchProduct

Cataract surgery in West Africa: is couching still a choice?

2012

business.industrymedicine.medical_treatmentVisual AcuityVision LowCataract ExtractionGeneral MedicineCataract surgeryBlindnessCataractWest africaCouchingAfrica WesternOphthalmologyHumansMedicineOptometrybusinessActa Ophthalmologica
researchProduct

Binocular vision alterations after refractive and cataract surgery: a review.

2018

To review binocular and accommodative disorders documented after corneal or intraocular refractive surgery, in normal healthy prepresbyopic patients. A bibliographic revision was performed; it included works published before 1st July 2017 where accommodation and/or binocularity was assessed following any type of refractive surgical procedure. The search in Pubmed yielded 1273 papers, 95 of which fulfilled the inclusion criteria. Few publications reporting binocular vision and/or accommodative changes after refractive surgery in normal subjects were found. The reduction in fusional vergence is the most frequently reported alteration. Anisometropia is an important risk factor for postoperativ…

genetic structuresmedicine.medical_treatmentUlls -- Acomodació i refraccióEstrabismeCataract Extraction:Ciències de la visió::Optometria::Visió binocular [Àrees temàtiques de la UPC]:Ciències de la visió::Optometria::Acomodació i refracció [Àrees temàtiques de la UPC]Eye--Accommodation and refraction03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRefractive surgerymedicineDiplopiaHumansAnisometropiaVision Binocularbusiness.industryVision TestsCataractes -- CirurgiaFusional vergenceAccommodation OcularGeneral MedicineCataract surgerymedicine.diseaseVisió binoculareye diseasesRefractive Surgical ProceduresStrabismusContact lensOphthalmologyAccommodative convergenceCataract -- Surgery030221 ophthalmology & optometryOptometryBinocular visionbusinessBinocular visionAccommodation030217 neurology & neurosurgeryActa ophthalmologica
researchProduct

Osmolality of various viscoelastic substances: comparative study.

2000

Abstract Purpose To determine the osmolality of various viscoelastic substances. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, and Institute for Medical Device Testing, Memmingen, Germany. Methods The analysis was carried out according to the European Pharmacopoeia by means of a calibrated osmometer using the freezing-point depression method. Each syringe was analyzed as a duplicate analysis. Results Mean osmolalities (mOsmol/kg) of the sodium hyaluronate viscoelastic substances were Allervisc® 299; Allervisc® Plus 307; Amvisc® Plus 335; AMO Vitrax® 284; Biolon® 279; Dispasan® 311; Dispasan® Plus 314; Healon® 295; Healon GV® 312; Healon®5 322; HYA-Ophtal® 376; M…

medicine.medical_specialtyCorneal endotheliumAnterior ChamberSodium hyaluronateCataract ExtractionMethylcelluloseOsmolar ConcentrationInjectionsCorneachemistry.chemical_compoundHypromellose DerivativesOsmometerOphthalmologymedicineHumansIn patientProtease InhibitorsHyaluronic AcidViscoelastic SubstancesOsmotic concentrationbusiness.industryOsmolar ConcentrationReproducibility of ResultsHypromellose DerivativesSensory SystemsOphthalmologychemistrySurgerybusinessJournal of cataract and refractive surgery
researchProduct