Search results for "Catheter"
showing 10 items of 482 documents
Evaluating the quality of implantation of percutaneous ventricular restoration device (Parachute®) by cardiac computed tomography
2016
Background The Parachute is a novel percutaneously implanted ventricular partitioning device (VPD) that has emerged as a safe and feasible treatment option for patients with heart failure following anterior wall myocardial infarction. VPD efficacy is likely dependent on optimal device placement, but to date there are no published data examining the effect of device positioning on patient outcomes. Methods and results We retrospectively identified 32 patients successfully implanted with the Parachute device, all of whom underwent cardiac computed tomography (CCT) at baseline and after 6 months of follow-up. Patients were divided into two groups based on self-reported improvement in New York …
Die direkte perkutane radiologische Jejunostomie (PRJ) und Duodenostomie: eine retrospektive Auswertung
2005
Purpose: To present our experience with direct percutaneous radiologic duodenostomy and jejunostomy (PRJ) for alimentation. Materials and Methods: A retrospective study identified 24 patients who had undergone percutaneous jejunostomy or duodenostomy guided by CT and fluoroscopy over a period of 9 years. Whenever possible, the jejunum was inflated with a 5 French diagnostic catheter and jejunopexy was performed using Cope anchors (T-fasteners). A 12 to 14 French locking pigtail drain was inserted for alimentation. In 8 patients, percutaneous direct jejunostomy was performed using only fluoroscopy. In 9 patients, both CT and fluoroscopy were used to guide the jejunostomy. In all 7 patients w…
Review article: Percutaneous transhepatic biliary drainage: Experience with 311 procedures
1988
Percutaneous biliary drainage was performed in 296 patients on 311 occasions using a fine-needle puncture technique. In 59%, the procedure served as postoperative decompression, and in 35% for palliation of obstruction, particularly in malignant disease. Postoperative drainage for the management of postoperative complication accounted for 2.5%. In more than 80% of the patients treated, the underlying disease was malignant obstructive jaundice. In 257 retrospectively evaluated patients the following complications were observed: cholangitis (6.6%), sepsis (3.1%), bile leakage (1.6%) with two deaths (0.7%), and subcapsular hematoma and hematoma in the hepatoduodenal ligament (1.2%). Catheter d…
A new approach using high volume blood patch for prevention of post-dural puncture headache following intrathecal catheter pump exchange.
2015
Background: In an observational study, complications of intrathecal catheter pumps necessitating surgical exchange were analyzed. Also the use of a high-volume prophylactic epidural blood patch (EBP) during surgery for preventing post-dural puncture headache (PDPH) with a follow-up for 1 year is described. Materials and Methods: In 22 patients with refractory chronic pain of cancer/noncancer origin or severe spasticity, who were receiving intrathecal morphine including adjuvants or baclofen for symptom relief, catheter exchange with or without pump was performed. In patients with documented symptoms of PDPH following initial intrathecal catheter implantation, a prophylactic EBP with a high …
Bleeding during transfer is the only parameter of patient anatomy and embryo quality that affects reproductive outcome: a prospective study.
2009
There is very little information available regarding the relevance of the position of embryo replacement during ET and the different anatomic characteristics of the recipient in the transfer process and on the result of assisted reproduction techniques. We prospectively analyzed, using multivariate regression analysis, 375 ETs, 177 of which were from donated oocytes and 198 from patients' own oocytes, and we found no effect of the anatomic characteristics of the uterus on the chances of achieving pregnancy when data were analyzed according to patient age and embryo quality. Interestingly, there was a significant decrease in pregnancy rates when blood was present in the catheter after the pr…
Steep blood pressure increase in low birth weight newborns
2004
CAD Modeling for Evaluating LVOT Obstruction in Transcatheter Mitral Valve Replacement
2019
The current generation of transcatheter heart valves (THV), as the Edwards SAPIEN 3 Ultra (S3), is not specifically designed for mitral position implantation and has intrinsic design geometry that may make mitral implantation suboptimal. This study aimed to develop a computed-tomography (CT) based CAD workflow for the preoperative planning of transcatheter mitral valve replacement (TMVR) by evaluating the resulting obstruction in the left ventricular outflow tract (LVOT). Specifically, the computational framework to reconstruct heart anatomy and virtually deploy the THV into mitral valve annulus was developed and successively applied to the cases of two patients who experienced annuloplasty…
Modifications in Ventricular Fibrillation and Capture Capacity Induced by a Linear Radiofrequency Lesion
2012
[EN] Introduction and objectives: An analysis was made of the effects of a radiofrequency-induced linear lesion during ventricular fibrillation and the capacity to capture myocardium through high-frequency pacing. Methods: Using multiple epicardial electrodes, ventricular fibrillation was recorded in 22 isolated perfused rabbit hearts, analyzing the activation maps upon applying trains of stimuli at 3 different frequencies close to that of the arrhythmia: a) at baseline; b) after radio-frequency ablation to induce a lesion of the left ventricular free wall (length=10 [1] mm), and c) after lengthening the lesion (length=23 [2] mm). Results: Following lesion induction, the regularity of the r…
Endoscopic radiofrequency ablation of a cholangiocarcinoma with targeted intraductal cholangioscopic access.
2020
Changes in the Spectral Characteristics of Ventricular Fibrillation in Lesions Produced by Radiofrequency Ablation. An Experimental Study
2008
INTRODUCTION AND OBJECTIVES Although electro- physiological databases contain information about changes in the time domain in lesions produced by radiofrequency ablation, very few data on changes in the frequency domain are available. The aim of this study was to investigate changes in the spectral characteristics of ventricular fibrillation in zones with radiofrequency lesions. METHODS Recordings of ventricular fibrillation were obtained in 11 isolated perfused rabbit heart preparations using a multiple epicardial electrode located on the left ventricular free wall. Spectral parameters derived by Fourier analysis before and after the creation of transmural radiofrequency lesions were compa…