Search results for "Catheter"
showing 10 items of 482 documents
Stepwise Approach to Atrial Fibrillation Mapping and Ablation in Persistent and Long-standing Persistent Atrial Fibrillation
2019
Use of central venous catheter and increased risk of ischemic stroke
2020
Use of wearable cardioverter‐defibrillator in association with catheter ablation for atrial fibrillation‐related tachycardiomyopathy
2019
Implantable cardioverter‐defibrillator (ICD) implantation is not indicated in patients with potentially transient or reversible causes of sudden cardiac death (SCD). Wearable cardioverter‐defibrillator (WCD) is increasingly used for SCD prevention in patients who are temporary at high risk of ventricular arrhythmia. Hereby, we describe a case of tachycardiomyopathy successfully managed with ablation and WCD backup. Implantable cardioverter‐defibrillators are a Class I indication by American College of Cardiology/American Heart Association/Heart Rhythm Society guidelines to prevent SCD in patients with nonischemic dilated cardiomyopathy, New York Heart Association (NYHA) functional class II …
Dressings and Securement Devices of Peripheral Arterial Catheters in Intensive Care Units and Operating Theaters
2020
Background: Hemodynamic monitoring, implemented by the placement of peripheral arterial catheters (PACs), is a characterizing aspect of the intensive care units. Peripheral arterial catheters can continually detect blood pressure and quickly conduct blood sampling. The use of PACs is generally considered safe, without serious complications. Currently, only 25% of the implanted catheters are actually subject to complications, including accidental removal, dislocation, occlusion, and infection. All of these complications arise from inadequate catheter stabilization at the level of the skin. This study aimed to summarize and describe the effectiveness and characteristics of dressings and secur…
Primary Persistent Atrial Fibrillation: A Distinct Arrhythmia Subentity of an Ablation Population
2015
INTRODUCTION Persistent atrial fibrillation (persAF) can occur either as a sustained arrhythmia that has progressed from initially paroxysmal AF or as primary persAF without a history of any spontaneously terminated episode. There is a paucity of data differentiating between the 2 different persAF entities. Thus, we prospectively evaluated baseline characteristics, electrophysiological features, and ablation outcome in these 2 patient cohorts. METHODS AND RESULTS A total number of 154 consecutive persAF patients (63 ± 10 years, f = 42, longstanding persAF = 60) were characterized in terms of having primary persAF (P-persAF group) or persAF that secondarily progressed from paroxysmal AF (S-p…
Determinants of elevated carbohydrate antigen 125 in patients with severe symptomatic aortic valve stenosis referred for transcatheter aortic valve i…
2018
Elevated carbohydrate antigen 125 (CA125) predicts adverse outcome after transcatheter aortic valve implantation (TAVI). While known underlying pathophysiological mechanisms of elevated CA125 include serosal effusions and inflammatory stimuli, clinical determinants associated with elevated CA125 in patients referred for TAVI remain unknown. Therefore, we investigated clinical, laboratory and echocardiographic determinants of elevated CA125 in patients with severe aortic valve stenosis referred for TAVI.This study includes 650 patients with severe aortic stenosis referred for TAVI. Baseline CA125 was determined by an immunoassay and dichotomized (elevated versus normal) based on the manufact…
The Incidence of Audible Steam Pops Is Increased and Unpredictable With the ThermoCool® Surround Flow Catheter During Left Atrial Catheter Ablation: …
2015
Audible Steam Pops During Left Atrial Catheter AblationIntroduction Open irrigated radiofrequency (RF) ablation catheters with a porous tip (56 holes, TC-SF) permit delivering RF energy in a temperature-controlled mode without temperature rise. This prospective observational study investigated the association of different catheter parameters on the occurrence of audible steam pops during left atrial (LA) ablation. Methods and Results A total of 226 patients underwent TC-SF catheter ablation for atrial fibrillation. RF power delivery, impedance and catheter tip temperature were continually recorded throughout the ablation. Pulmonary vein isolation was performed with a maximum of 27 W and LA …
Transcatheter indirect mitral annuloplasty induces annular and left atrial remodelling in secondary mitral regurgitation
2020
Abstract Aims Mitral annuloplasty using the Carillon Mitral Contour System (CMCS) reduces secondary mitral regurgitation (SMR) and leads to reverse left ventricular remodelling. The aim of this study was to evaluate the effect of the CMCS on the mitral valve annulus (MA) and left atrial volume (LAV). Methods and results We retrospectively evaluated the data of all patients treated with the CMCS at our centre. Using transthoracic echocardiography, MA diameters were assessed by measuring the anterolateral to posteromedial extend (ALPM) and the anterior to posterior (AP) dimensions, respectively. Also, LAV and left ventricular end‐diastolic volume (LVEDV) were assessed. Patients were examined …
Transcatheter Mitral Repair for Functional Mitral Regurgitation According to Left Ventricular Function: A Real-Life Propensity-Score Matched Study
2020
Background: Transcatheter mitral valve repair (TMVR) could improve survival in functional mitral regurgitation (FMR), but it is necessary to consider the influence of left ventricular ejection fraction (LVEF). Therefore, we compare the outcomes after TMVR with Mitraclip®
Peripheral facial palsy following ventriculoperitoneal shunt. The lesson we have learned
2018
The most frequent complications after shunt surgery are infective and obstructive. Other types are less common, and eventually occur due to technical errors during brain ventricular puncture, opening the intraperitoneal cavity or the tunnelling of the catheter between the two points. Although rare, there are well-reported complications related to the poor positioning of the distal catheter, with perforation of organs and tissues.We report a very rare case of a male patient with normal pressure hydrocephalus submitted to ventriculoperitoneal shunt. During tunnelling of the shunt stylet, a peripheral facial palsy due to injury to the extra cranial segment of the facial nerve occurred.To the b…