Search results for "Catheterization"
showing 10 items of 191 documents
A new thrombectomy catheter device (AngioJet) for the disruption of thrombi: An in vitro study
1999
In this study we examined a new thrombectomy catheter device. Different kinds of in vitro generated thrombi and cadaver thrombi were disrupted in test tubes. The mean disruption rate (and disruption time for 1 g of thrombus) was 225 +/- 65 mg/sec (5 +/- 2 sec) for whole-blood, 117 +/- 60 mg/sec (12 +/- 9 sec) for fibrin, 41 +/- 18 mg/sec (30 +/- 18 sec) for mixed, 70 +/- 42 mg/sec (17 +/- 5 sec) for unorganized, 45 +/- 8 mg/sec (22 +/- 4 sec) for partly, and 5 +/- 1 mg/sec (216 +/- 29 sec) for completely organized cadaver thrombi (P0.05). More than 99% of fragmented particles of whole-blood thrombi were 0-12 microm in diameter. The particle size of fibrin, mixed, and cadaver thrombi was sim…
Interventional and surgical modalities of treatment for pulmonary arterial hypertension
2004
AbstractBeyond medical therapy, different interventional and surgical approaches exist for treatment of pulmonary arterial hypertension (PAH). Atrial septostomy has been applied in patients with lack of response to medical therapy in the absence of other surgical treatment options. With growing experience, procedure-related death rates have been reduced to 5.4%, and the most suitable patient group has been identified among patients with a mean right atrial pressure between 10 and 20 mm Hg. Pulmonary endarterectomy is the accepted form of treatment for patients with chronic thromboembolic pulmonary hypertension. Establishing the diagnosis and the classification of the type of lesions by pulm…
Dressings and Securement Devices of Peripheral Arterial Catheters in Intensive Care Units and Operating Theaters
2020
Background: Hemodynamic monitoring, implemented by the placement of peripheral arterial catheters (PACs), is a characterizing aspect of the intensive care units. Peripheral arterial catheters can continually detect blood pressure and quickly conduct blood sampling. The use of PACs is generally considered safe, without serious complications. Currently, only 25% of the implanted catheters are actually subject to complications, including accidental removal, dislocation, occlusion, and infection. All of these complications arise from inadequate catheter stabilization at the level of the skin. This study aimed to summarize and describe the effectiveness and characteristics of dressings and secur…
Determination of myocardial perfusion and coronary flow reserve by densitometric measurements: a selective classification of regions of interest
2002
To evaluate the functional effect of a coronary artery stenosis on the dependent myocardium, digitized coronary angiograms (DCAs) were recorded. The DCAs, acquired during heart catheterization, provide information about myocardial perfusion and coronary flow reserve of areas supplied by this coronary artery. For each analysis the myocardium is separated into different regions of interest (ROIs); 16 ROIs in the distribution of the LCA and 8 ROIs for the RCA. In addition to that, the ROIs of the diseased vessels are divided into ROIs which are proximal, within and distal to the stenosis. Using a semiautomatic procedure, densograms are constructed from which the parameter rise time is calculat…
Parametric assessment of myocardial perfusion by densitometric evaluation of digital subtraction coronary angiograms: a comparison with tomographic T…
2002
Densitometric results about local myocardial perfusion are compared with those derived from a quantitative analysis of TL-201 single photon emission computer tomograms (TL-201 SPECT). Ten patients underwent conventional TL-201 SPECT at rest and after maximum bicycle stress and dipyridamole infusion the day prior to the investigation. SPECT was applied to provide improved spatial resolution for the detection of perfusion abnormalities. During the catheterization procedure four digital subtraction coronary angiograms were performed, two of the left and two of the right coronary artery both before and after pharmacologically induced hyperemia by intracoronary papaverine. The densitometric para…
Morphologische und funktionelle Evaluation pulmonaler Gefäßanomalien mittels schneller MR-Techniken
2002
Purpose: To evaluate breath-hold MR techniques for morphologic and functional assessment of vascular abnormalities of the pulmonary vasculature. Patients and Methods: 13 patients aged 11 to 60 years with different vascular abnormalities of the pulmonary vasculature (5 patients with 16 arteriovenous malformations, 8 patients with partial anomalous pulmonary venous return) underwent MR imaging at 1.5 T. For morphological assessment, a contrast-enhanced 3D MR angiography (ce-MRA) was performed after a timing run. Segmented cine- and velocity-encoded GRE sequences were used for delineation of associated cardiac septal defects and for determination of systemic left-to-right or intrapulmonary shu…
[Antimicrobically coated venous catheters--must? Contra].
2002
Influence of blood sampling from venipunctures and catheter systems on serial determinations of prothrombin activation fragment 1 + 2 and thrombin-an…
1993
To evaluate the influence of different blood sampling techniques on test results of thrombin-antithrombin III complex (TAT) and prothrombin fragment 1 + 2 (F1 + 2) serial determinations were performed. In six groups of nonrandomized patients (ten patients each) the concentrations of the coagulation markers of blood samples from central catheters (internal jugular, caval, Shaldon, pulmonary artery) and peripheral cannulas (17G and 18G) were compared with those of blood samples obtained simultaneously from direct venipunctures of the contralateral arm. Medians and 25th-75th percentiles of TAT and F1 + 2 concentrations of plasmas obtained from central catheters were not different from those ta…
Transcatheter embolization of the kidney with butyl-2-cyanoacrylate: Experimental and clinical results
1978
The technique and efficacy of therapeutic catheter embolization of the kidney with butyl-2-cyanoacrylate (Histoacryl) were studied in 80 rabbits (including control groups) and in 10 dogs. A mixture of butyl-2-cyanoacrylate, 50% glucose, and tantalum powder was used for the embolization. Complete and permanent vascular occlusion was found in nearly all cases. The main complication observed was a reflux of embolizing material into the lumbar arteries, which occurred in seven rabbits. Clinically, therapeutic embolization was performed in six patients with hypernephroma. The indication for embolization in these patients, as well as in two others with iatrogenic lesions, was pronounced hematuria…
Bloodstream Infection Incidence of Different Central Venous Catheters in Neonates: A Descriptive Cohort Study
2017
Central venous catheters (CVCs) in neonates are associated with a risk of central line-associated bloodstream infections (CLABSI). Most reports on the incidence of CLABSI in neonates focus on umbilical venous catheters (UVCs) and peripherally inserted central catheters (PICCs). We evaluated the incidence and risk factors for CLABSI in a cohort of neonates with femoral venous catheters (FVCs), UVCs, and PICCs, with a gestational age ≥34 weeks born between January 1, 2006 and June 30, 2013. We included 2,986 neonates with a total of 656 catheters. The CLABSI incidence rate varied from 12.3 per 1,000 catheter-days in FVCs to 10.6 per 1,000 catheter-days in UVCs and 5.3 per 1,000 catheter-days …