Search results for "Catheterization"
showing 10 items of 191 documents
Contrast echocardiography of the left ventricle an independent predictor of pulmonary artery pressure?
1994
To test the hypothesis that left heart opacification is dependent on pulmonary artery pressure, we analyzed consecutively 12 patients with normal and 8 patients with abnormal pulmonary artery pressure with a new lung capillary stable echo contrast agent. Patients underwent contrast echocardiographic examination within 6 hours before right and left heart catheterization with 200 mg/ml and 400 mg/ml SHU 508A intravenously. The mean pulmonary artery pressure was 15.4 mmHg in the patients with normal pulmonary artery pressures and 46.4 mmHg in the patients with pulmonary hypertension (p0.000). Echocardiograms were video-intensitometrically analyzed for intensity maximum (MAX), half-time of vide…
Noninvasive assessment of pulmonary hemodynamics in patients with chronic thromboembolic pulmonary hypertension by high temporal resolution phase-con…
2013
Background— Right heart catheterization is the gold standard for assessment of pulmonary hemodynamics in patients with chronic thromboembolic pulmonary hypertension. To date, MRI has not been able to produce precise measurements of mean pulmonary arterial pressure (mPAP). The purpose of the study was to create a model for estimating mPAP and pulmonary vascular resistance in patients with chronic thromboembolic pulmonary hypertension by high temporal resolution phase-contrast MRI (PC-MRI) and to correlate the results with simultaneously acquired, invasive catheter-based measurements (simultaneously measured mPAP) and with right heart catheterization measurements. Methods and Results— A tota…
Parametric assessment of myocardial perfusion during interventional cardiac catheterization by means of X-ray densitometry-short-and long-term result…
1990
X-ray densitometric evaluation of digital subtraction angiocardiograms allows an assessment of myocardial perfusion by means of the parameter 'MEAN RISE TIME' (MRT), defined as the time from the onset of local myocardial contrast medium opacification to the point of maximum opacification. Best results are obtained when the response of that parameter is compared before and after stimulation of coronary flow by papaverine. A prolongation of this parameter, especially after papaverine, was indicative of an impairment of myocardial perfusion, when compared to the results of TL-201 scintigraphy. In 50 patients with single vessel coronary artery disease the results of MRT pre and post papaverine …
The effect of balloon dilatation on post-stenotic myocardial perfusion before and after stimulation of coronary flow reserve: evaluation by the densi…
1988
From densitometric evaluation of digital subtraction cineangiocardiograms the parameter 'Mean Rise Time' (MRT), defined as the time from the onset of local myocardial contrast medium opacification to the point of maximal opacification can be derived; this parameter revealed a close correlation with the results on myocardial perfusion obtained by Thallium-201 scintigraphy. A prolonged 'Mean Rise Time' was indicative of an impairment of myocardial perfusion. We have developed a heart-phase gated real-time digitization procedure and computer-supported method for the densitometric estimation of the MRT to obtain information about the effect of coronary balloon dilatation on myocardial perfusion…
Real-time ultrasound-guided infraclavicular axillary vein cannulation: A prospective study in mechanically ventilated critically ill patients.
2016
Purpose: The main purpose of this study was to define the venipuncture and catheterization success rates and early mechanical complication rates of ultrasound-guided infraclavicular axillary vein cannulation. Materials and methods: We performed in-plane, real-time, ultrasound-guided infraclavicular axillary vein catheterizations under emergency and nonemergency conditions in mechanically ventilated, critically ill patients. Results: We performed 202 cannulation attempts. One hundred and twenty-six procedures (62.4%) were performed under emergency conditions. The puncture of the axillary vein was successful in 98.5% of patients, and the entire procedure success rate was 95.1% (95% confidence…
Home parenteral nutrition-associated thromboembolic and bleeding events: results of a cohort study of 236 individuals
2016
UNLABELLED Essentials Sparse or outdated studies focus on thrombotic and bleeding risk in home parenteral nutrition (HPN). 236 HPN patients followed at a single center for a total of 684 patient-years were evaluated. Rates of venous thrombosis and major bleeding, and prevalence of vena cava syndrome are provided. Anticoagulants might reduce thrombosis risk, but population-specific safety concerns remain. SUMMARY Background Home parenteral nutrition (HPN) is necessary for patients with intestinal failure. Recurrent catheter-related thrombosis (CRT) is common, leading to infectious complications, pulmonary embolism, vascular access loss and intestinal transplantation. The efficacy and safety …
Major urinary dysfunction after mesorectal excision for rectal carcinoma
2004
Abstract Background Urinary dysfunction may occur after mesorectal excision and pelvic autonomic nerve preservation (PANP) in patients with rectal carcinoma. The aim of this prospective study was to identify factors predictive of long-term urinary catheterization. Methods Two hundred and ten patients without significant urological problems underwent resection of rectal cancer with mesorectal excision. The number of patients with complete, partial or no identification of the nerves was documented and correlated with possible predictive factors for postoperative major urinary dysfunction. Results Eight patients (3·8 per cent) required long-term urinary catheterization: two after complete PANP…
Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography
1996
The aim of this study was the evaluation of the diagnostic potentials of transesophageal 3D- echocardiography in the determination of mitral valve stenosis. 54 patients were investigated by transthoracic and multiplane transesophageal echocardiography. In 41 patients cardiac catheterization was performed. 3D- echocardiographic data acquisition was performed by automatic transducer rotation at 2 degree increments over a span of 180 degrees. The transesophageal probe was linked to an ultrasound unit and to a 3D- workstation capable of ECG- and respiration gated data acquisition, postprocessing and 2D/3D image reconstruction. The mitral valve was visualized in sequential cross-sectional planes…
Plasma levels of atrial natriuretic peptide and hemodynamic function in cardiac disease.
1993
Plasma concentrations of atrial natriuretic peptide were measured in eight patients with cardiac disease but normal resting right atrial pressure, during cardiac catheterization. No patient had clinical evidence of overt heart failure. An increase in peptide concentrations was observed between the aorta or the peripheral vein and the pulmonary artery. A linear relation was found between peripheral vein and pulmonary artery peptide concentration. Mean pulmonary artery and capillary wedge pressure also correlated with the peptide levels. No correlation was observed between mean right atrial pressure and peptide concentration. These findings demonstrate that atrial natriuretic peptide release,…
Estimation of pulmonary arterial pressure by measuring the size of the right pulmonary artery in the suprasternal echocardiogram.
1982
We studied 175 patients within 24 hr before cardiac catheterization with suprasternal echocardiography to evaluate whether pulmonary arterial hypertension can be derived by measuring the size of the right pulmonary artery. Group I consisted of 103 patients without pulmonary arterial hypertension (enddiastolic less than or equal to 12 mm Hg; mean pressure less than 20 mm Hg) and group II consisted of 72 patients with pulmonary arterial hypertension. The right pulmonary artery could be imaged in 91.2% of the patients studied. The size of the right pulmonary artery at the end of diastole in group I measured 17.9 +/- 0.2 mm (mean +/- SEM) and correlated best to the body surface area in this gro…