Search results for "Catheterization"
showing 10 items of 191 documents
The Drainage System of the Paranasal Sinuses: A Review with Possible Implications for Balloon Catheter Dilation
2011
Background Intersinus connections and accessory ostia of the maxillary sinus are well known to rhinologic surgeons but are less known for the remaining paranasal sinuses. Probing and dilatation of the natural ostia of diseased sinuses is being popularized currently by the clinical value of balloon catheter dilation (BCD). Although short-term high success rates with treatment of the dilated ostia/duct have been reported with this technique, the potential impact of fractures of adjacent bony septae on accessory sinus ostia, on mucosally lined surfaces, and on intersinus drainage pathways still has not been considered. The aim of this study was to review the literature on accessory sinus ostia…
“Three-level shock” in ablation-refractory paroxysmal atrial fibrillation
1987
His-bundle ablation is a very effective method to control drug-refractory supraventricular arrhythmias. We present a 69-year-old woman with paroxysmal atrial fibrillation, in whom several attempts of unipolar and bipolar His-bundle ablation were ineffective. Ultimately a stable 2/1 atrioventricular block was induced when three successive shocks of 400 W were applied. The first shock was given in that position with the largest His-potential deflection. The other two shocks were applied at catheter positions more distal and more proximal from the first one, respectively. We suppose that the initial lack of success was due to an atypical atrioventricular junction anatomy.
Computed tomography imaging needs for novel transcatheter tricuspid valve repair and replacement therapies
2020
Abstract Transcatheter tricuspid valve therapies are an emerging field in structural heart interventions due to the rising number of patients with severe tricuspid regurgitation and the high risk for surgical treatment. Computed tomography (CT) allows exact measurements of the annular plane, evaluation of adjacent structures, assessment of the access route, and can also be used to identify optimal fluoroscopic projection planes to enhance periprocedural imaging. This review provides an overview of current transcatheter tricuspid valve repair and replacement therapies and to what extent CT can support these interventions.
Safety and efficacy of left atrial appendage occlusion with the ACP or Watchman device guided by intracardiac echocardiography from the left atrium
2021
Abstract Background There is a paucity of randomized data regarding the safety and efficacy of the use of intracardiac echocardiography (ICE) from the left atrium (LA) to guide left atrial appendage occlusion (LAAO) procedures under local anesthesia using either of the available devices. Hypothesis The aim of this study was to compare the efficacy and safety of ICE from the LA with transesophageal echocardiography (TEE) for guidance during transcatheter LAAO procedures. Methods Single‐center, cohort study of patients undergoing LAAO with the Amplatzer Cardiac Plug or Watchman device. Procedures were guided by ICE from the LA with local anesthesia (n = 175) or TEE under general anesthesia (n…
Centre procedural volume and adverse in‐hospital outcomes in patients undergoing percutaneous transvenous edge‐to‐edge mitral valve repair usingMitra…
2021
AIMS The number of transcatheter mitral valve repair (TMVr) procedures has increased substantially during the last years. A better understanding of the relationship between hospital volume of transcatheter transvenous mitral valve repairs using MitraClip® and patient outcomes may provide information for future policy decisions to improve patient management. METHODS AND RESULTS We analysed patient characteristics and in-hospital outcomes for all TMVr procedures using MitraClip® performed in Germany from 2011 to 2017. Hospitals were stratified according to centre volumes and patients were compared for baseline characteristics and adverse in-hospital events. Overall, 24 709 inpatients were tre…
Tricuspid valve repair with the Cardioband system: two-year outcomes of the multicentre, prospective TRI-REPAIR study
2021
AIMS: Tricuspid regurgitation (TR) is associated with high morbidity and mortality rates with limited treatment options. We report one- and two-year outcomes of the Cardioband tricuspid valve reconstruction system in the treatment of ≥moderate functional TR in the TRI-REPAIR study. METHODS AND RESULTS: Thirty patients were enrolled in this single-arm, multicentre, prospective study. Patients were evaluated as having ≥moderate, symptomatic functional TR and deemed inoperable due to unacceptable surgical risk. Clinical, functional, and echocardiographic data were prospectively collected up to two years (mean duration 604±227 days). At baseline, 83% were in NYHA Class III-IV, and the mean LVEF…
Thrombosis, fracture, and percutaneous removal of a patent foramen ovale closure device 1 month after successful deployment
2010
Several different devices have been developed for the percutaneous closure of interatrial defects and patent foramen ovale. Although the implantation of these devices is both safe and effective, a number of complications, both in the early and the late follow-up, may occur. We describe a case of device fracture manifested early (1 month after implantation) with the formation of massive thrombosis on the right atrial disc. The patient was treated with anticoagulants and the device was percutaneously retrieved. Our images allowed early noninvasive therapy and emphasize the need for echocardiographic follow-up early after implantation. © 2010 Wiley-Liss, Inc.
Comparison of heparin to citrate as a catheter locking solution for non-tunneled central venous hemodialysis catheters in patients requiring renal re…
2014
Background The incidence of acute kidney injury (AKI) is estimated at 10 to 20% in patients admitted to intensive care units (ICU) and often requires renal replacement therapy (RRT). ICU mortality in AKI patients can exceed 50%. Venous catheters are the preferred vascular access method for AKI patients requiring RRT, but carry a risk of catheter thrombosis or infection. Catheter lock solutions are commonly used to prevent such complications. Heparin and citrate locks are both widely used for tunneled, long-term catheters, but few studies have compared citrate versus heparin for patients with short-term, non-tunneled catheters. We aim to compare citrate 4% catheter lock solution versus hepar…
Analyzing central-line associated bloodstream infection prevention bundles in 22 countries: The results of ID-IRI survey
2022
International audience; BACKGROUND: Because central line-associated bloodstream infections (CLABSIs) are a significant complication of central venous access, it is critical to prevent CLABSIs through the use of central line bundles. The purpose of this study was to take a snapshot of central venous access bundles in various countries. METHODS: The participants in intensive care units (ICUs) completed a questionnaire that included information about the health center, infection control procedures, and central line maintenance. The countries were divided into 2 groups: those with a low or low-middle income and those with an upper-middle or high income. RESULTS: Forty-three participants from 22…
In vitro efficacy of a Hydrophilic Central Venous Catheter Loaded with Silver to Prevent Microbial Colonization
1998
A method was developed to load the surface of a central venous catheter with silver to prevent bacterial colonization. Silver confers a broad antimicrobial activity with a relatively low risk of resistance. Catheters were incubated with a silver nitrate solution in different concentrations. The solvent, incubation temperature and incubation period were varied to examine the influence on the catheter loading. With increasing incubation temperature, time and concentration of silver nitrate, higher rates of silver elution were observed by atomic absorption spectroscopy. Furthermore, by using ethanol-water as a solvent instead of pure water, the amount of silver bound to the catheter surface wa…