Search results for "Catheterization"

showing 10 items of 191 documents

Relative incidence and mortality of congenital heart defects diagnosed by angiohemodynamic methods: a 17-year study.

1992

Over a 17-year period (January 1971 to January 1988), 2322 children, aged 0-14 years, were diagnosed as having congenital heart disease (CHD) by cardiac catheterization and angiography. Excluding those with highly complex or undiagnosed defects, there were 2156 children with CHD, 72.4% of whom were treated surgically, with a total surgical mortality rate of 24.1%. After a mean follow-up of 9 years the overall mortality of the cohort was 29.9%, 29.1% occurring in the first month of life, 39.6% between 1 month and 1 year, and 31.2% between 1 and 14 years. The incidence, mortality, and age at death of each cardiac defect are presented and compared with the results of other studies. The overall…

Cross-Cultural ComparisonHeart Defects CongenitalMalePediatricsmedicine.medical_specialtyCardiac CatheterizationHeart diseaseAdolescentRelative incidencemedicine.medical_treatmentCohort StudiesPostoperative ComplicationsmedicineHumansChildCardiac catheterizationmedicine.diagnostic_testbusiness.industryIncidence (epidemiology)AngiocardiographyPalliative CareHemodynamicsInfant NewbornInfantVascular surgerymedicine.diseaseCardiac surgerySurvival RateSpainChild PreschoolPediatrics Perinatology and Child HealthCohortAngiographyFemaleCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesPediatric cardiology
researchProduct

3D and multispectral imaging for subcutaneous veins detection.

2009

The first and perhaps most important phase of a surgical procedure is the insertion of an intravenous (IV) catheter. Currently, this is performed manually by trained personnel. In some visions of future operating rooms, however, this process is to be replaced by an automated system. Experiments to determine the best NIR wavelengths to optimize vein contrast for physiological differences such as skin tone and/or the presence of hair on the arm or wrist surface are presented. For illumination our system is composed of a mercury arc lamp coupled to a 10nm band-pass spectrometer. A structured lighting system is also coupled to our multispectral system in order to provide 3D information of the p…

Diagnostic ImagingOptics and PhotonicsComputer sciencemedia_common.quotation_subjectMultispectral imageImage processingInfusions Subcutaneouslaw.inventionCatheterizationVeinsAutomationOpticsImaging Three-DimensionallawMedical imagingImage Processing Computer-AssistedContrast (vision)Humansmedia_commonModels StatisticalSpectroscopy Near-InfraredSpectrometerOrientation (computer vision)business.industryEquipment DesignMercuryLinear discriminant analysisImage EnhancementAtomic and Molecular Physics and OpticsSpectrophotometryArc lampbusinessOptics express
researchProduct

Endoscopic interventions in the small bowel using double balloon enteroscopy: feasibility and limitations.

2007

Double-balloon enteroscopy (DBE) is a new endoscopic tool that not only allows diagnostic workup of small bowel diseases, but also makes it possible to carry out therapeutic interventions. However, for a variety of reasons, endoscopic therapy appears to be more difficult to carry out deep in the small bowel than in the upper or lower gastrointestinal tract.The purpose of this study was to evaluate the acute technical success and acute complication rate of DBE.Between June 2003 and July 2006, 353 patients (152 women, 201 men; mean age 60.3 +/- 17.1 yr) with suspected or known small bowel disease underwent 635 consecutive DBE procedures. The majority of the patients were suffering from midgas…

EnteroscopyAdultMalemedicine.medical_specialtyAdolescentEndoscopy GastrointestinalCatheterizationDouble-balloon enteroscopyIntestine SmallmedicineHumansAgedRetrospective StudiesAged 80 and overHepatologymedicine.diagnostic_testbusiness.industrydigestive oral and skin physiologyGastroenterologySingle-Balloon EnteroscopyMiddle Ageddigestive system diseasesSurgeryEndoscopyEndoscopes GastrointestinalIntestinal DiseasesTreatment OutcomeFeasibility StudiesFemalebusinessGastrointestinal HemorrhageThe American journal of gastroenterology
researchProduct

Balloon Enteroscopy: Single- and Double-Balloon Enteroscopy

2009

Balloon enteroscopy is a method that allows endoscopic inspection of the entire small bowel, or large parts of it, while simultaneously making it possible to obtain histologic samples and carry out treatment measures. Studies of double-balloon enteroscopy (DBE) have confirmed the high diagnostic yield of the procedure, with an acceptably low complication rate (approximately 1% for diagnostic DBE and 3% to 4% for therapeutic DBE). The principal indication for the procedure is midgastrointestinal bleeding, that is, when the bleeding source is located in the small bowel. With good patient selection, the diagnostic yield here is 70% to 80%, and this has a substantial influence on subsequent tre…

Enteroscopymedicine.medical_specialtymedicine.medical_treatmentBalloon EnteroscopyCapsule EndoscopyCatheterizationlaw.inventionCapsule endoscopylawLaparotomyDouble-balloon enteroscopyIntestine SmallmedicineHumansDuodenal Diseasesmedicine.diagnostic_testIleal Diseasesbusiness.industryGastroenterologySingle-Balloon EnteroscopyJejunal DiseasesSurgeryTherapeutic endoscopyRadiologyGastrointestinal HemorrhageIntraoperative enteroscopybusinessGastrointestinal Endoscopy Clinics of North America
researchProduct

Contractile Reserve and Extent of Transmural Necrosis in the Setting of Myocardial Stunning: Comparison at Cardiac MR Imaging

2010

To perform a comparison of cardiac magnetic resonance (MR) imaging-derived ejection fraction (EF) during low-dose dobutamine infusion (EF(D)) with the extent of segments with transmural necrosis in more than 50% of their wall thickness (ETN) for the prediction of major adverse cardiac events (MACEs) and late systolic recovery soon after a first ST-segment elevation myocardial infarction (STEMI).Institutional ethics committee approval and written informed consent were obtained. One hundred nineteen consecutive patients with a first STEMI, a depressed left ventricular EF, and an open infarct-related artery underwent MR imaging at 1 week after infarction. EF(D) and ETN (by using a 17-segment m…

Gadolinium DTPAMaleCardiac Catheterizationmedicine.medical_specialtyCardiotonic AgentsNecrosismedicine.medical_treatmentMyocardial InfarctionContrast MediaMagnetic Resonance Imaging CineNecrosisDobutamineInternal medicineAngioplastymedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesMyocardial infarctionCardiac catheterizationMyocardial StunningMyocardial stunningChi-Square DistributionEjection fractionmedicine.diagnostic_testbusiness.industryAngioplastyMagnetic resonance imagingMiddle Agedmedicine.diseaseMyocardial ContractionArea Under CurveRetreatmentcardiovascular systemCardiologyRegression AnalysisFemaleStentsDobutaminemedicine.symptombusinessmedicine.drugRadiology
researchProduct

Catheter-induced bladder gangrene.

1974

GangreneAdultMalemedicine.medical_specialtyRupture Spontaneousbusiness.industryUrologyUrinary Bladder Diseasesmedicine.diseaseShock SepticSurgeryGangreneCatheterShock (circulatory)medicineHumansmedicine.symptombusinessUrinary CatheterizationThe Journal of urology
researchProduct

DNA delivery to 'ex vivo' human liver segments.

2011

Hydrodynamic injection is an efficient procedure for liver gene therapy in rodents but with limited efficacy in large animals, using an 'in vivo' adapted regional hydrodynamic gene delivery system. We study the ability of this procedure to mediate gene delivery in human liver segments obtained by surgical resection. Watertight liver segments were retrogradely injected from hepatic vein with a saline solution containing a plasmid bearing the enhanced green fluorescent protein (eGFP) gene, under different conditions of flow rate (1, 10 and 20 ml s(-1)) and final perfused volume. Samples were cultured for 1 to 2 days and used for microscopy and molecular analysis of gene expression. The fluore…

Genetic enhancementGreen Fluorescent ProteinsGene Transfer TechniquesGenetic TherapyBiologyGene deliveryHepatic VeinsMolecular biologyGreen fluorescent proteinCatheterizationLiverIn vivoTranscription (biology)Gene expressionInjections IntravenousGeneticsHydrodynamicsMolecular MedicineHumansMolecular BiologyGeneEx vivoPlasmidsGene therapy
researchProduct

Transcatheter radiofrequency perforation and stent implantation for palliation of pulmonary atresia in a 3060-g infant

1995

In a 3060-g infant with fibromuscular pulmonary atresia an open right ventricular outflow tract was created by means of interventional cardiological methods. Following two inadvertent perforations without sequelae or clinical symptoms, radiofrequency perforation and subsequent balloon dilatation were successfully performed. The implantation of a Palmaz iliac stent led to a predictable communication between the right ventricle and pulmonary artery.

Heart Septal Defects VentricularCardiac Catheterizationmedicine.medical_specialtymedicine.medical_treatmentPerforation (oil well)Coronary Angiographymedicine.arterymedicineHumansVentricular outflow tractmedicine.diagnostic_testbusiness.industryInfant NewbornStentmedicine.diseaseSurgerymedicine.anatomical_structureEchocardiographyPulmonary AtresiaVentricleAtresiaAngiographyPulmonary arteryCatheter AblationFemaleStentsRadiologyCardiology and Cardiovascular MedicinePulmonary atresiabusinessCatheterization and Cardiovascular Diagnosis
researchProduct

Transcatheter edge-to-edge repair for tricuspid regurgitation in Barlow-type tricuspid valve prolapse

2020

Heart Valve Prosthesis ImplantationCardiac Catheterizationmedicine.medical_specialtyTricuspid Valve Prolapsebusiness.industryRegurgitation (circulation)Tricuspid Valve InsufficiencyTreatment OutcomeTricuspid Valve InsufficiencyInternal medicineCardiologymedicineHumansTricuspid ValveTricuspid Valve ProlapseCardiology and Cardiovascular MedicinebusinessEuropean Heart Journal
researchProduct

Numerical simulation of transcatheter mitral valve replacement: The dynamic implication of LVOT obstruction in the valve-in-ring case.

2022

Transcatheter mitral valve replacement (TMVR) has been used for “off-label” treatment when annuloplasty band ring for mitral repair fails. However, the complex anatomy and function of the mitral valve may lead to fatal complications as a result of the left ventricular outflow tract (LVOT) obstruction in TMVR. We report the structural and hemodynamic response of LVOT obstruction resulting from TMVR with the Edwards SAPIEN 3 Ultra (S3) device. We modified the original Living Heart Human Model (LHHM) to account for a failed mitral valve with an annuloplasty band ring and simulated the cardiac beating condition in the setting of S3 device implantation. Findings demonstrated a high dynamic behav…

Heart Valve Prosthesis ImplantationHeart Defects CongenitalHistoryCardiac CatheterizationPolymers and PlasticsRehabilitationBiomedical EngineeringBiophysicsMitral Valve InsufficiencyFinite Element (FE) analysisIndustrial and Manufacturing EngineeringVentricular Outflow ObstructionTreatment OutcomeRisk FactorsComputational Fluid Dynamic (CFD)Living heart human modelHeart Valve ProsthesisHumansMitral ValveOrthopedics and Sports MedicineBusiness and International ManagementTranscatheter mitral valve replacementJournal of biomechanics
researchProduct