Search results for "Catheterization"
showing 10 items of 191 documents
Relative incidence and mortality of congenital heart defects diagnosed by angiohemodynamic methods: a 17-year study.
1992
Over a 17-year period (January 1971 to January 1988), 2322 children, aged 0-14 years, were diagnosed as having congenital heart disease (CHD) by cardiac catheterization and angiography. Excluding those with highly complex or undiagnosed defects, there were 2156 children with CHD, 72.4% of whom were treated surgically, with a total surgical mortality rate of 24.1%. After a mean follow-up of 9 years the overall mortality of the cohort was 29.9%, 29.1% occurring in the first month of life, 39.6% between 1 month and 1 year, and 31.2% between 1 and 14 years. The incidence, mortality, and age at death of each cardiac defect are presented and compared with the results of other studies. The overall…
3D and multispectral imaging for subcutaneous veins detection.
2009
The first and perhaps most important phase of a surgical procedure is the insertion of an intravenous (IV) catheter. Currently, this is performed manually by trained personnel. In some visions of future operating rooms, however, this process is to be replaced by an automated system. Experiments to determine the best NIR wavelengths to optimize vein contrast for physiological differences such as skin tone and/or the presence of hair on the arm or wrist surface are presented. For illumination our system is composed of a mercury arc lamp coupled to a 10nm band-pass spectrometer. A structured lighting system is also coupled to our multispectral system in order to provide 3D information of the p…
Endoscopic interventions in the small bowel using double balloon enteroscopy: feasibility and limitations.
2007
Double-balloon enteroscopy (DBE) is a new endoscopic tool that not only allows diagnostic workup of small bowel diseases, but also makes it possible to carry out therapeutic interventions. However, for a variety of reasons, endoscopic therapy appears to be more difficult to carry out deep in the small bowel than in the upper or lower gastrointestinal tract.The purpose of this study was to evaluate the acute technical success and acute complication rate of DBE.Between June 2003 and July 2006, 353 patients (152 women, 201 men; mean age 60.3 +/- 17.1 yr) with suspected or known small bowel disease underwent 635 consecutive DBE procedures. The majority of the patients were suffering from midgas…
Balloon Enteroscopy: Single- and Double-Balloon Enteroscopy
2009
Balloon enteroscopy is a method that allows endoscopic inspection of the entire small bowel, or large parts of it, while simultaneously making it possible to obtain histologic samples and carry out treatment measures. Studies of double-balloon enteroscopy (DBE) have confirmed the high diagnostic yield of the procedure, with an acceptably low complication rate (approximately 1% for diagnostic DBE and 3% to 4% for therapeutic DBE). The principal indication for the procedure is midgastrointestinal bleeding, that is, when the bleeding source is located in the small bowel. With good patient selection, the diagnostic yield here is 70% to 80%, and this has a substantial influence on subsequent tre…
Contractile Reserve and Extent of Transmural Necrosis in the Setting of Myocardial Stunning: Comparison at Cardiac MR Imaging
2010
To perform a comparison of cardiac magnetic resonance (MR) imaging-derived ejection fraction (EF) during low-dose dobutamine infusion (EF(D)) with the extent of segments with transmural necrosis in more than 50% of their wall thickness (ETN) for the prediction of major adverse cardiac events (MACEs) and late systolic recovery soon after a first ST-segment elevation myocardial infarction (STEMI).Institutional ethics committee approval and written informed consent were obtained. One hundred nineteen consecutive patients with a first STEMI, a depressed left ventricular EF, and an open infarct-related artery underwent MR imaging at 1 week after infarction. EF(D) and ETN (by using a 17-segment m…
Catheter-induced bladder gangrene.
1974
DNA delivery to 'ex vivo' human liver segments.
2011
Hydrodynamic injection is an efficient procedure for liver gene therapy in rodents but with limited efficacy in large animals, using an 'in vivo' adapted regional hydrodynamic gene delivery system. We study the ability of this procedure to mediate gene delivery in human liver segments obtained by surgical resection. Watertight liver segments were retrogradely injected from hepatic vein with a saline solution containing a plasmid bearing the enhanced green fluorescent protein (eGFP) gene, under different conditions of flow rate (1, 10 and 20 ml s(-1)) and final perfused volume. Samples were cultured for 1 to 2 days and used for microscopy and molecular analysis of gene expression. The fluore…
Transcatheter radiofrequency perforation and stent implantation for palliation of pulmonary atresia in a 3060-g infant
1995
In a 3060-g infant with fibromuscular pulmonary atresia an open right ventricular outflow tract was created by means of interventional cardiological methods. Following two inadvertent perforations without sequelae or clinical symptoms, radiofrequency perforation and subsequent balloon dilatation were successfully performed. The implantation of a Palmaz iliac stent led to a predictable communication between the right ventricle and pulmonary artery.
Transcatheter edge-to-edge repair for tricuspid regurgitation in Barlow-type tricuspid valve prolapse
2020
Numerical simulation of transcatheter mitral valve replacement: The dynamic implication of LVOT obstruction in the valve-in-ring case.
2022
Transcatheter mitral valve replacement (TMVR) has been used for “off-label” treatment when annuloplasty band ring for mitral repair fails. However, the complex anatomy and function of the mitral valve may lead to fatal complications as a result of the left ventricular outflow tract (LVOT) obstruction in TMVR. We report the structural and hemodynamic response of LVOT obstruction resulting from TMVR with the Edwards SAPIEN 3 Ultra (S3) device. We modified the original Living Heart Human Model (LHHM) to account for a failed mitral valve with an annuloplasty band ring and simulated the cardiac beating condition in the setting of S3 device implantation. Findings demonstrated a high dynamic behav…